Air-jacketed CO₂ Incubator LMAC-A102

Air-jacketed CO₂ Incubator LMAC-A102 offers 160 L stainless steel inner chamber ensures corrosion resistance and easy cleaning. Built in 2 adjustable shelves for flexible storage and optimal organization of samples. Equipped with temperature range from RT+5°C to 60°C supports a wide variety of cell culture requirements. It features microcomputer-based PID technology that ensures stable and contact-free heating distribution. Our Air-jacketed CO₂ Incubator provides UV sterilization that actively minimizes contamination through surface disinfection. 

Catalog Send Mail Whatsapp

Specifications

Chamber Volume 160 L
Temperature Range RT+5°C to 60°C
Temperature Fluctuation ±0.3°C (at 37°C)
Temperature Uniformity ±0.5°C (at 37°C)
Temperature Resolution 0.1℃
Temperature Sensor PT100
Sterilization Method UV sterilization
Heating Method Air-jacketed, Microcomputer PID control
Inner Chamber Material Stainless Steel
Timing Range 0 to 999 hours or continuous
Display 7-inch touch screen
Alarm System High/low temperature and CO₂ concentration alarm
No. Of Shelves 2 adjustable shelves
CO₂ Control Infrared (IR) sensor
CO₂ Concentration Range 0 to 20 vol%
CO₂ Concentration Uniformity 0.2 vol%
CO₂ Control Resolution 0.1 vol%
Filter Co₂ gas filter, HEPA filter
Ambient Temperature And Humidity 5 to 30℃ (Recommendation: 25±2℃), Less than or equal to 80% RH
Power Consumption 1000W
Power Supply AC220V, 50/60Hz
Internal Dimension (W×D×H) 477×473×711 mm
External Dimension (W×D×H) 700×666×1101 mm
Packaging Dimension (W×D×H) 795×835×1270 mm
Net Weight 88 kg
Gross Weight 110 kg

Features

Infrared CO₂ Sensor

Dual Filtration System

7-Inch Touch Screen Display

Programmable Timer

Alarm Safety Alert

Standard Accessories

Model No.Accessory
LMAC-A102-S1Shelves
LMAC-A102-U1USB Interface
LMAC-A102-V1CO₂ Relief Valve
LMAC-A102-G1CO₂ Gas Filter

Optional Accessories

Model No.Accessory
LMAC-A102-WT1Water Pump and Three-Way Connector

Applications

Air-jacketed CO₂ Incubator LMAC-A102 is vital for detecting microbial contamination and fermentation processes in food and beverage industries.

Similar Products

Infrared CO₂ Incubator LMIRI-A101

  • Chamber Volume: 160 L
  • Temperature Range: Room temperature +5°C to 50°C
  • Temperature Resolution: ± 0.5℃
  • Heating Mode: Water-jacket
  • Sterilization Method: Biologic filter and UV disinfection

Air-jacketed CO₂ Incubator LMAC-A100

  • Chamber Volume: 50 L
  • Temperature Range: RT+5°C to 60°C
  • Temperature Fluctuation: ±0.3°C (at 37°C)
  • Temperature Uniformity: ±0.5°C (at 37°C)
  • Temperature Resolution: 0.1℃

CO2 Incubator LMCOI-A102

  • Volume: 260 L
  • Temperature Range: Room temperature +5 to 55 ℃
  • Ambient Temperature Range: 18 to 30 ℃
  • Temperature Fluctuation: ±0.3 ℃
  • Temperature Uniformity: ±0.5 ℃
Water-jacketed CO2 Incubator LMWC-A102
  • Chamber Volume: 240 L
  • Shelves: 3 pieces
  • Heating Method: Water-jacketed, PID Control
  • Sterilization method: UV Sterilizer
  • Temperature Range: RT+5 to 50℃
CO2 Incubator LMCOI-A104
  • Volume: 180 L
  • Temperature Range: Room temperature +5 to 55 ℃
  • Ambient Temperature Range: 18 to 30 ℃
  • Temperature Fluctuation: ±0.3 ℃
  • Temperature Uniformity: ±0.5 ℃

Air-jacketed CO₂ Incubator LMAC-A103

  • Chamber Volume: 100 L
  • Temperature Range: RT+5°C to 60°C
  • Temperature Fluctuation: ±0.3°C (at 37°C)
  • Temperature Uniformity: ±0.5°C (at 37°C)
  • Temperature Resolution: 0.1℃

Water-jacketed CO₂ Incubator LMWC-A100

  • Chamber Volume: 80 L
  • Temperature Range: RT+5°C to 60°C
  • Temperature Fluctuation: ±0.3°C (at 37°C)
  • Temperature Uniformity: ±0.5°C (at 37°C)
  • Temperature Resolution: 0.1℃

Air Jacketed CO2/O2 Incubator LMAOC-A100

  • Temperature Range: +5~60°C
  • Control Type: Microcomputer Controller
  • Temperature Fluctuation: ≤±0.3°C
  • Temperature Uniformity: ≤0.5°C
  • CO2 Range: 0~20%
CO₂ Incubator LMCOI-A101
  • Chamber Volume: 160 L
  • Temperature Range: Room temperature +5°C to 50°C
  • Temperature Resolution: ± 0.5℃
  • Heating Mode: Water-jacket
  • Inner Chamber Material: Stainless Steel with inner glass door
CO2 Incubator LMCOI-A103
  • Volume: 100 L
  • Temperature Range: Room temperature +5 to 55 ℃
  • Ambient Temperature Range: 18 to 30 ℃
  • Temperature Fluctuation: ±0.3 ℃
  • Temperature Uniformity: ±0.5 ℃

Water-jacketed CO₂ Incubator LMWC-A101

  • Chamber Volume: 160 L
  • Temperature Range: RT+5°C to 60°C
  • Temperature Fluctuation: ±0.3°C (at 37°C)
  • Temperature Uniformity: ±0.5°C (at 37°C)
  • Temperature Resolution: 0.1℃

Air-jacketed CO₂ Incubator LMAC-A104

  • Chamber Volume: 80 L
  • Temperature Range: RT+5°C to 60°C
  • Temperature Fluctuation: ±0.3°C (at 37°C)
  • Temperature Uniformity: ±0.5°C (at 37°C)
  • Temperature Resolution: 0.1℃

Air-jacketed CO₂ Incubator LMAC-A105

  • Chamber Volume: 160 L
  • Temperature Range: RT+5°C to 60°C
  • Temperature Fluctuation: ±0.3°C (at 37°C)
  • Temperature Uniformity: ±0.5°C (at 37°C)
  • Temperature Resolution: 0.1℃
CO2 Incubator LMCOI-A105
  • Volume: 260 L
  • Temperature Range: Room temperature +5 to 55 ℃
  • Ambient Temperature Range: 18 to 30 ℃
  • Temperature Fluctuation: ±0.3 ℃
  • Temperature Uniformity: ±0.5 ℃
CO₂ Incubator LMCOI-A100
  • Chamber Volume: 80 L
  • Temperature Range: Room temperature +5°C to 50°C
  • Temperature Resolution: ± 0.5℃
  • Heating Mode: Water-jacket
  • Inner Chamber Material: Stainless Steel with inner glass door

Frequently Asked Questions

1 What is a CO2 Incubator?

A CO2 Incubator is an apparatus designed to create a controlled environment for cell and tissue culture by maintaining optimal temperature, humidity, and CO2 levels.

2 How does CO2 Incubator maintain CO2 levels?

It maintains CO2 levels through a sensor-based feedback system that regulates the injection of CO2 gas to ensure a stable and ideal culture environment.

3 How is CO2 Incubator used in stem cell research?

It is used in stem cell research to maintain the precise environmental conditions necessary for the proliferation and differentiation of stem cells.

4 How does CO2 Incubator benefit cancer cell culture studies?

It benefits cancer cell culture studies by enabling consistent growth conditions for tumor cell lines, facilitating drug testing and cellular response analysis.

5 What role does CO2 Incubator play in vaccine development?

It plays a key role in vaccine development by supporting the cultivation of cell lines required for virus propagation and antigen production.

6 How is CO2 Incubator used in pharmaceutical quality control?

It is used in pharmaceutical quality control to test the effects of drugs on cultured cells under tightly controlled environmental conditions.

7 Why is CO2 Incubator important in regenerative medicine?

It is important in regenerative medicine as it supports the culture of cells used for tissue engineering and repair therapies.

8 What is the role of CO2 Incubator in protein expression studies?

It provides a stable culture environment for host cells used in recombinant protein expression, critical for research and therapeutic production.

9 How is CO2 Incubator applied in toxicology testing?

It is applied in toxicology testing by maintaining the viability of cultured cells exposed to various chemical agents to evaluate cytotoxic effects.

10 In what way does CO2 Incubator support biomedical device testing?

It supports biomedical device testing by allowing devices to be tested in vitro with live cells under physiologically relevant conditions.