Analytical Balance LMBA-A103 is designed to offer weighing capacity up to 210 g. Integrates high-readability load cell, it ensures reliable evaluation. Equipped with an antistatic coating windshield, it minimizes interference. It features convertible measuring units, including grams, milligrams, carats, ounces, and troy ounces. Our Balance enables quantifying test samples, formulations, and density determination in research and pharmaceutical labs.

Catalog Send Mail Whatsapp

Specifications

Weighing Range 0 to 210 g
Readability 0.1 mg
Calibration Internal
Calibration Weight 100 g
Repeatability 0.0002
Pan Size ɸ 80 mm
Stable Time ≤ 8 Seconds
Ambient Temperature 20 °C ± 2.5 °C
Relative Humidity 50 to 70 %
Operating Modes Basic weighing, Parts counting, Density weighing, Check weighing, Percentage weighing, Animal weighing
Voltage 220 V; 50 Hz
Dimension 520 × 380 × 500 mm
Weight 10 kg

Features

LCD display

Automatic calibration

Multi-point correction

Electromagnetic sensor

RS232 interface

Level adjustment

Easy navigation

Standard Accessories

Model NoTypeImage
LB-01Plier 
LB-02Universal Adapter 
LB-03Dust Cover 

Applications

Analytical Balance LMBA-A103 is ideal for weighing test samples, standard preparations formulation, differential weighing, and density determination. It is commonly employed in research and pharmaceutical laboratories to determine the mass of solids, liquids, powders, and granular substances.

Similar Products

Analytical Balance LMBA-A105

  • Capacity: 120 g
  • Readability: 0.0001 g
  • Calibration: Internal
  • Repeatability: 0.0001 g
  • Linearity: ±0.0002 g

Analytical Balance LMBA-C101

  • Capacity: 82/220 g
  • Readability: 0.00001 g / 0.0001 g
  • Minimum Weighing: 0.06 mg / 0.6 mg
  • Operation Temperature: 5 to 25℃
  • Stable Time: ≤ 6 s

Analytical Balance LMBA-A202

  • Weighing Range: 0 - 300 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Repeatability: 0.0002
  • Pan Size: Φ 90 mm
Analytical Balance LMBA-B101
  • Capacity: 120g
  • Readability: 0.01g
  • Calibration: External
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm
Analytical Balance LMBA-B202
  • Weighing Range: 0 - 300 g
  • Readability: 0.1 mg
  • Calibration: External
  • Repeatability: 0.0002 g
  • Pan Size: Φ 90 mm

Analytical Balance LMBA-B103

  • Capacity: 220g
  • Readability: 0.01g
  • Calibration: External
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm

Analytical Balance LMBA-C200

  • Capacity: 320g
  • Repeatability: ± 0.0002g
  • Resolution: 0.0001 g
  • Response Time: ≤ 3 sec
  • Operation Temperature: 15° C to 35° C

Analytical Balance LMBA-A101

  • Capacity: 120g
  • Readability: 0.01g
  • Calibration: Internal
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm
Analytical Balance LMBA-A104
  • Capacity: 220g
  • Readability: 0.01g
  • Calibration: Internal
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm
Analytical Balance LMBA-B100
  • Capacity: 100g
  • Readability: 0.01g
  • Calibration: External
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm

Analytical Balance LMBA-A102

  • Weighing Range: 0 to 200 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Calibration Weight: 100 g
  • Repeatability: 0.0002

Analytical Balance LMBA-B102

  • Capacity: 200g
  • Readability: 0.01g
  • Calibration: External
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm

Analytical Balance LMBA-B300

  • Weighing Range: 0 to 600g
  • Readability: 0.001g
  • Repeatability: ≤ 0.003 g
  • Pan Size: Circle 130 mm (SST 304)
  • Stabilization Speed: 2s
Analytical Balance LMBA-A201
  • Weighing Range: 0 - 200 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Repeatability: 0.0002
  • Pan Size: Φ 90 mm
Analytical Balance LMBA-B104
  • Weighing Capacity: 0 to 220g
  • Readability: 0.1mg
  • Calibration: External
  • Pan Size: 80 mm
  • Working Space Height: 240 mm

Frequently Asked Questions

1 What is an Analytical Balance?

An Analytical Balance is an apparatus designed to measure mass with precision.

2 Why is Analytical Balance important in laboratory settings?

It is important in laboratory settings because it ensures the precision required for scientific experiments, chemical formulations, and quality control processes.

3 How does Analytical Balance function?

It functions by using electromagnetic force compensation to counteract the weight of a sample, allowing for accurate mass measurement.

4 How should Analytical Balance be maintained?

It should be maintained by keeping it clean, calibrating regularly, avoiding exposure to chemicals or moisture, and ensuring it is used in a stable, draft-free environment.

5 How is Analytical Balance used in pharmaceutical laboratories?

It is used to precisely measure active pharmaceutical ingredients (APIs) and excipients to ensure accurate drug formulation and dosage.

6 Can Analytical Balance be used in environmental testing?

It is used in environmental testing to weigh fine particulate matter, soil, or residue samples for contamination analysis and regulatory compliance.

7 Why is Analytical Balance essential in chemical synthesis?

It is essential in chemical synthesis to measure reactants with high accuracy, which is critical for achieving the correct stoichiometry and reaction yield.

8 How does Analytical Balance contribute to food quality testing?

It is used to measure small quantities of additives, vitamins, or contaminants, ensuring the product meets safety and nutritional standards.

9 Can Analytical Balance be used in forensic science?

It is used in forensic science to weigh trace evidence such as powders, fibers, or residues, which can be vital in criminal investigations.

10 How is Analytical Balance used in nanotechnology applications?

It is used to weigh extremely small amounts of substances for nanoparticle synthesis, where accuracy is crucial due to the small scales involved.