Analytical Balance LMBA-B102

Analytical Balance LMBA-B102 offers handling capacity up to 200g. It stabilizes readings within 3 seconds, enhancing workflow efficiency. It features a tare function, allowing users to reset weight after placing a container. Built with a compact 80 mm pan for reliable measuring of small and delicate samples. Our analytical balances incorporate built-in overload protection, ensuring durability and safeguarding against damage.

Catalog Send Mail Whatsapp

Specifications

Capacity 200g
Readability 0.01g
Calibration External
Repeatability ±0.0002g
Pan Size 80 mm
Accuracy 0.1mg
Linearity ±0.0003g
Weighing Units Gram, carat, pound, ounce, newton
Stability Time Less than or equal to 3 seconds
Working Temperature 15°C to 35°C
Communication Interface RS232
Dimension 300 × 200 × 295 mm
Net Weight 5.7 kg

Features

External Calibration mode

RS232 Communication Interface

Wide Temperature range

Lightweight construction

Multiple Weighing Units

Standard Accessories

Power cable

Weighing pan

Applications

Analytical Balance LMBA-B102 is essential in laboratories for measuring small amounts of toxic substances and chemicals.

Similar Products

Analytical Balance LMBA-B200

  • Weighing Range: 0 - 100 g
  • Readability: 0.1 mg
  • Calibration: External
  • Repeatability: 0.0002 g
  • Pan Size: Φ 90 mm

Analytical Balance LMBA-B201

  • Weighing Range: 0 - 200 g
  • Readability: 0.1 mg
  • Calibration: External
  • Repeatability: 0.0002 g
  • Pan Size: Φ 90 mm

Analytical Balance LMBA-B202

  • Weighing Range: 0 - 300 g
  • Readability: 0.1 mg
  • Calibration: External
  • Repeatability: 0.0002 g
  • Pan Size: Φ 90 mm
Analytical Balance LMBA-C101
  • Capacity: 82/220 g
  • Readability: 0.00001 g / 0.0001 g
  • Minimum Weighing: 0.06 mg / 0.6 mg
  • Operation Temperature: 5 to 25℃
  • Stable Time: ≤ 6 s
Analytical Balance LMBA-A103
  • Weighing Range: 0 to 210 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Calibration Weight: 100 g
  • Repeatability: 0.0002

Analytical Balance LMBA-A101

  • Capacity: 120g
  • Readability: 0.01g
  • Calibration: Internal
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm

Analytical Balance LMBA-B100

  • Capacity: 100g
  • Readability: 0.01g
  • Calibration: External
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm

Analytical Balance LMBA-A202

  • Weighing Range: 0 - 300 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Repeatability: 0.0002
  • Pan Size: Φ 90 mm
Analytical Balance LMBA-A100
  • Weighing Range: 0 to 100 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Calibration Weight: 100 g
  • Repeatability: 0.0002
Analytical Balance LMBA-A102
  • Weighing Range: 0 to 200 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Calibration Weight: 100 g
  • Repeatability: 0.0002

Analytical Balance LMBA-A105

  • Capacity: 120 g
  • Readability: 0.0001 g
  • Calibration: Internal
  • Repeatability: 0.0001 g
  • Linearity: ±0.0002 g

Analytical Balance LMBA-B101

  • Capacity: 120g
  • Readability: 0.01g
  • Calibration: External
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm

Analytical Balance LMBA-C100

  • Capacity: 62/120 g
  • Min Weighing: 0.06 mg / 0.6 mg
  • Resolution: 0.00001 g / 0.0001 g
  • Operation Temperature: 5 to 25℃
  • Stable Time: ≤ 6 s
Analytical Balance LMBA-B300
  • Weighing Range: 0 to 600g
  • Readability: 0.001g
  • Repeatability: ≤ 0.003 g
  • Pan Size: Circle 130 mm (SST 304)
  • Stabilization Speed: 2s
Analytical Balance LMBA-C200
  • Capacity: 320g
  • Repeatability: ± 0.0002g
  • Resolution: 0.0001 g
  • Response Time: ≤ 3 sec
  • Operation Temperature: 15° C to 35° C

Frequently Asked Questions

1 What is an Analytical Balance?

An Analytical Balance is an apparatus designed to measure mass with precision.

2 Why is Analytical Balance important in laboratory settings?

It is important in laboratory settings because it ensures the precision required for scientific experiments, chemical formulations, and quality control processes.

3 How does Analytical Balance function?

It functions by using electromagnetic force compensation to counteract the weight of a sample, allowing for accurate mass measurement.

4 How should Analytical Balance be maintained?

It should be maintained by keeping it clean, calibrating regularly, avoiding exposure to chemicals or moisture, and ensuring it is used in a stable, draft-free environment.

5 How is Analytical Balance used in pharmaceutical laboratories?

It is used to precisely measure active pharmaceutical ingredients (APIs) and excipients to ensure accurate drug formulation and dosage.

6 Can Analytical Balance be used in environmental testing?

It is used in environmental testing to weigh fine particulate matter, soil, or residue samples for contamination analysis and regulatory compliance.

7 Why is Analytical Balance essential in chemical synthesis?

It is essential in chemical synthesis to measure reactants with high accuracy, which is critical for achieving the correct stoichiometry and reaction yield.

8 How does Analytical Balance contribute to food quality testing?

It is used to measure small quantities of additives, vitamins, or contaminants, ensuring the product meets safety and nutritional standards.

9 Can Analytical Balance be used in forensic science?

It is used in forensic science to weigh trace evidence such as powders, fibers, or residues, which can be vital in criminal investigations.

10 How is Analytical Balance used in nanotechnology applications?

It is used to weigh extremely small amounts of substances for nanoparticle synthesis, where accuracy is crucial due to the small scales involved.