Get Quote

Contact us now to receive a detailed quotation.

Analytical Balance LMBA-C101

Analytical Balance LMBA-C101 is a benchtop balance, capable of weighing up to 82/220 grams with a high readability of 0.00001 g/0.0001 g. Integrated with a weighing sensor which improves response speed, enhancing the performance of the balance. The control panel is equipped with five operational buttons for easy access.

Catalog Send Mail Whatsapp

Specifications

Capacity 82/220 g
Readability 0.00001 g / 0.0001 g
Minimum Weighing 0.06 mg / 0.6 mg
Operation Temperature 5 to 25℃
Stable Time ≤ 6 s
Repeatability 0.05 / 0.1 mg
Display LCD (green backlight with black font)
Pan Size Φ 80 mm
Liner ± 0.1/ ± 0.2 mg
Power 110 to 230 V, 50/60 Hz
Draft Shield Size 162 × 171 × 225 mm
Dimension 345 × 215 × 345 mm
Net Weight 7 kg

Features

Enhanced with electromagnetic force weighing system
Designed with Plastic protection keyboard
Provides a Large-screen graphic display
Stores database up to 99 recipes, a maximum of 20 in each
Equipped with multi-language record and save weight values in GLP/ISO format
Automatic calibration and multi-point correction system
Cast aluminum outer covering

Applications

Used for sample/standard preparation, formulation, differential weighing, density determination, interval weighing, and pipette routine testing..

Similar Products

Analytical Balance LMBA-B300

  • Weighing Range: 0 to 600g
  • Readability: 0.001g
  • Repeatability: ≤ 0.003 g
  • Pan Size: Circle 130 mm (SST 304)
  • Stabilization Speed: 2s

Analytical Balance LMBA-A100

  • Weighing Range: 0 to 100 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Calibration Weight: 100 g
  • Repeatability: 0.0002

Analytical Balance LMBA-A200

  • Weighing Range: 0 - 100 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Repeatability: 0.0002
  • Pan Size: Φ 90 mm
Analytical Balance LMBA-A104
  • Capacity: 220g
  • Readability: 0.01g
  • Calibration: Internal
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm
Analytical Balance LMBA-A201
  • Weighing Range: 0 - 200 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Repeatability: 0.0002
  • Pan Size: Φ 90 mm

Analytical Balance LMBA-B202

  • Weighing Range: 0 - 300 g
  • Readability: 0.1 mg
  • Calibration: External
  • Repeatability: 0.0002 g
  • Pan Size: Φ 90 mm

Analytical Balance LMBA-B104

  • Weighing Capacity: 0 to 220g
  • Readability: 0.1mg
  • Calibration: External
  • Pan Size: 80 mm
  • Working Space Height: 240 mm

Analytical Balance LMBA-B102

  • Capacity: 200g
  • Readability: 0.01g
  • Calibration: External
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm
Analytical Balance LMBA-A101
  • Capacity: 120g
  • Readability: 0.01g
  • Calibration: Internal
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm
Analytical Balance LMBA-A102
  • Weighing Range: 0 to 200 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Calibration Weight: 100 g
  • Repeatability: 0.0002

Analytical Balance LMBA-C100

  • Capacity: 62/120 g
  • Min Weighing: 0.06 mg / 0.6 mg
  • Resolution: 0.00001 g / 0.0001 g
  • Operation Temperature: 5 to 25℃
  • Stable Time: ≤ 6 s

Analytical Balance LMBA-A202

  • Weighing Range: 0 - 300 g
  • Readability: 0.1 mg
  • Calibration: Internal
  • Repeatability: 0.0002
  • Pan Size: Φ 90 mm

Analytical Balance LMBA-A105

  • Capacity: 120 g
  • Readability: 0.0001 g
  • Calibration: Internal
  • Repeatability: 0.0001 g
  • Linearity: ±0.0002 g
Analytical Balance LMBA-C200
  • Capacity: 320g
  • Repeatability: ± 0.0002g
  • Resolution: 0.0001 g
  • Response Time: ≤ 3 sec
  • Operation Temperature: 15° C to 35° C
Analytical Balance LMBA-B100
  • Capacity: 100g
  • Readability: 0.01g
  • Calibration: External
  • Repeatability: ±0.0002g
  • Pan Size: 80 mm

Frequently Asked Questions

1 What is an Analytical Balance?

An Analytical Balance is an apparatus designed to measure mass with precision.

2 Why is Analytical Balance important in laboratory settings?

It is important in laboratory settings because it ensures the precision required for scientific experiments, chemical formulations, and quality control processes.

3 How does Analytical Balance function?

It functions by using electromagnetic force compensation to counteract the weight of a sample, allowing for accurate mass measurement.

4 How should Analytical Balance be maintained?

It should be maintained by keeping it clean, calibrating regularly, avoiding exposure to chemicals or moisture, and ensuring it is used in a stable, draft-free environment.

5 How is Analytical Balance used in pharmaceutical laboratories?

It is used to precisely measure active pharmaceutical ingredients (APIs) and excipients to ensure accurate drug formulation and dosage.

6 Can Analytical Balance be used in environmental testing?

It is used in environmental testing to weigh fine particulate matter, soil, or residue samples for contamination analysis and regulatory compliance.

7 Why is Analytical Balance essential in chemical synthesis?

It is essential in chemical synthesis to measure reactants with high accuracy, which is critical for achieving the correct stoichiometry and reaction yield.

8 How does Analytical Balance contribute to food quality testing?

It is used to measure small quantities of additives, vitamins, or contaminants, ensuring the product meets safety and nutritional standards.

9 Can Analytical Balance be used in forensic science?

It is used in forensic science to weigh trace evidence such as powders, fibers, or residues, which can be vital in criminal investigations.

10 How is Analytical Balance used in nanotechnology applications?

It is used to weigh extremely small amounts of substances for nanoparticle synthesis, where accuracy is crucial due to the small scales involved.