Sample Concentrator LMSCN-B100

Sample Concentrator LMSCN-B100 is designed with 0 to 160℃ temperature setting range. It features microprocessor and PID fuzzy control for stable heating and consistent performance. Equipped with an automatic fault detection and alarm system, it prevents operational interruptions and hazards. Integrates nitrogen blowing on sample surface to speed solvent evaporation without oxygen exposure. Our Concentrator is ideal for sample concentration and separation for food, pharmaceutical, and biological product testing.

Catalog Send Mail Whatsapp

Specifications

Temperature Setting Range 0 to 160℃
Temperature Control Range RT+5 to 160℃
Block Quantity 1
Nitrogen Flow Rate 15L/min
Heating Time Less than or equal to 15min (from 25 to 160℃)
Timing Range 1min to 99min59sec/∞
Temperature Accuracy Less than or equal to ±0.5℃ at 40℃, Less than or equal to ±1℃ at 120℃
Temperature Uniformity Less than or equal to ±0.5℃
Display Accuracy 0.1℃
Maximum Vertical Travel 200 mm
Nitrogen Pressure 0.02Mpa (Gas needle Less than or equal to 16pcs), 0.05Mpa (Gas needle greater than16pcs)
Power Consumption 300W
Power Supply AC220V or AC110V, 50/60Hz
Dimensions 260×220×450 mm
Weight 7 Kg

Pricing

Product Price Unit Action
Sample Concentrator LMSCN-B100 $ 1462.5 Each of 1

Features

Digital display

High stability

Over-temperature protection

Uniform heating

Low maintenance

Optional Accessories

Model No.

Accessory

LMSCN-B100-B1

10mm×24 Block

LMSCN-B100-B2

12mm×24 Block

LMSCN-B100-B3

13mm×24 Block

LMSCN-B100-B4

15mm×16 Block

LMSCN-B100-B5

16mm×16 Block

LMSCN-B100-B6

19mm×12 Block

LMSCN-B100-B7

20mm×12 Block

LMSCN-B100-B8

26mm×8 Block

LMSCN-B100-B9

28mm×4 Block

LMSCN-B100-B10

40mm×3 Block

LMSCN-B100-I1

1.5ml×24 Block

LMSCN-B100-I2

2.0ml×24 Block

LMSCN-B100-V1

Flow control valve

Applications

Sample Concentrator LMSCN-B100 enables solvent evaporation and separation for residue analysis, food testing, environmental checks, pharmaceutical research, and biological product processing in various industries.

Similar Products

Standard Sample Concentrator LMSCN-A102

  • Block Quantity: 1
  • Temperature Control Range: RT +5℃ to 150℃
  • Temperature Set Range: 0℃ to 150℃
  • Heating Up Rate: Less than or equal to 30min (20℃ to 150℃)
  • Temperature Stability at 40℃: ±0.3℃

$ 1725 / Each of 1

Standard Sample Concentrator LMSCN-A103

  • Block Quantity: 2
  • Temperature Control Range: RT +5℃ to 150℃
  • Temperature Set Range: 0℃ to 150℃
  • Heating Up Rate: Less than or equal to 30min (20℃ to 150℃)
  • Temperature Stability at 40℃: ±0.3℃

$ 1800 / Each of 1

Sample Concentrator LMSCN-B103

  • Temperature Setting Range: 0 to 160℃
  • Temperature Control Range: RT+5 to 160℃
  • Block Quantity: 2
  • Nitrogen Flow Rate: 15L/min
  • Heating Time: Less than or equal to 15min (from 25 to 160℃)

$ 1850 / Each of 1

Sample Concentrator LMSCN-B101
  • Temperature Setting Range: 0 to 160℃
  • Temperature Control Range: RT+5 to 160℃
  • Block Quantity: 2
  • Nitrogen Flow Rate: 15L/min
  • Heating Time: Less than or equal to 15min (from 25 to 160℃)

$ 1600 / Each of 1

Standard Sample Concentrator LSCC-A100
  • Temperature Range: RT + 5 °C- 150 °C
  • Blocks Quantity: 1 piece
  • Height of gas needle: 150 mm
  • Temperature accuracy ( 40-100 °C): ± 0.5 °C
  • Temperature accuracy ( 100-150 °C): ± 1 °C

$ 3600 / Pack of 1

Standard Sample Concentrator LSCC-A101

  • Temperature Range: RT + 5 °C- 150 °C
  • Blocks Quantity: 2 pieces
  • Height of gas needle: 150 mm
  • Temperature accuracy ( 40-100 °C): ± 0.5 °C
  • Temperature accuracy ( 100-150 °C): ± 1 °C

$ 3212.5 / Pack of 1

Sample Concentrator LMSCN-B102

  • Temperature Setting Range: 0 to 160℃
  • Temperature Control Range: RT+5 to 160℃
  • Block Quantity: 1
  • Nitrogen Flow Rate: 15L/min
  • Heating Time: Less than or equal to 15min (from 25 to 160℃)

$ 1650 / Each of 1

Sample Concentrator LMSCN-A100

  • Sample Capacity: 1 standard block
  • Temperature Control Range: Room Temperature +5℃ to 150℃
  • Temperature Setting Range: 5℃ to 150℃
  • Temperature Stability at 40 to 100℃: ±0.5℃
  • Temperature Stability at 100 to 150℃: ±1℃

$ 1800 / Each of 1

Sample Concentrator LMSCN-A101
  • Sample Capacity: 2 standard blocks
  • Temperature Control Range: Room Temperature +5℃ to 150℃
  • Temperature Setting Range: 5℃ to 150℃
  • Temperature Stability at 40 to 100℃: ±0.5℃
  • Temperature Stability at 100 to 150℃: ±1℃

$ 1875 / Each of 1

Sample Concentrator LMSCN-B104
  • Temperature Control Range: RT+5 to 160℃
  • Block Quantity: 1
  • Heating Time: Less than or equal to 15min (from 25 to 160℃)
  • Timing Range: 1min to 99min59sec/∞
  • Maximum Gas Flow: 15L/min

$ 1675 / Each of 1

Frequently Asked Questions

1 What is a Standard Sample Concentrator?

A Standard Sample Concentrator is an apparatus designed to evaporate solvents from multiple samples simultaneously using controlled heat and gas flow.

2 How does a Standard Sample Concentrator work

It works by applying a gentle stream of inert gas, typically nitrogen, and heat to accelerate the evaporation of solvents from test samples.

3 What types of samples can be used with a Standard Sample Concentrator?

It is suitable for concentrating liquid samples.

4 Can Standard Sample Concentrator be used for high-throughput analysis?

It is ideal for high-throughput analysis due to its ability to process multiple samples simultaneously with reproducible results.

5 How is Standard Sample Concentrator used in pharmaceutical testing?

In pharmaceutical testing, it is used to remove solvents from drug formulations or extracts before chromatographic or spectroscopic analysis.

6 Can Standard Sample Concentrator be used for pesticide residue analysis?

It is commonly used in pesticide residue analysis to concentrate extracts from food or environmental samples for improved detection sensitivity.

7 What role does Standard Sample Concentrator play in environmental testing?

In environmental testing, it is used to evaporate solvents from water, soil, or air samples to concentrate pollutants or contaminants for further analysis.

8 How does Standard Sample Concentrator help in forensic laboratories?

It assists forensic laboratories by concentrating trace evidence or chemical residues, improving detection limits in toxicology or drug testing.

9 Can Standard Sample Concentrator be used in food safety labs?

It is widely used in food safety labs to prepare and concentrate samples for analysis of contaminants such as mycotoxins, pesticides, and additives.

10 How does Standard Sample Concentrator assist in quality control procedures?

It enhances quality control procedures by ensuring consistent and efficient sample preparation, leading to more accurate and reproducible test results.