Ask An Expert

We will Follow up with you within 24 hours.

Titration analysis repeatability

pH Range

Burette Repeatability

Allowable error of titration capacity

pH Resolutions

Potentiometric Titrator

The Labmate Potentiometric Titrator boasts swift, interchangeable imported burette assemblies, featuring intelligent volume recognition. This potentiometric autotitrator is exceptionally versatile, catering to a wide range of industrial applications. Equipped with a composite differential electrode amplifier unit for potentiometric and voltammetric/Karl Fisher titration, it supports various electrode types. It offers three primary titration modes: incremental, equilibrium, and cut-off, facilitating diverse titration processes. Additionally, the device includes a real-time clock for displaying time and generating runtime-indicated reports. It offers seamless weight transfer through a well-balanced interface. Users can conveniently store up to 50 methods and print method parameter reports, enhancing efficiency and documentation in laboratory processes.

Potentiometric titrator LMPT-301

  • pH Range: 0 to 14.00 pH
  • pH Resolutions: 0.01 pH
  • pH Accuracy: ±0.03 pH
  • mV Range: 0 to ±1400 mV
  • mV Resolutions: 1 mV

Potentiometric titrator LMPT-302

  • Burette Repeatability: 0.2%
  • Burette Accuracy: 10 ml Burette: ±0.025 ml;20 ml Burette: ±0.035 ml
  • Burette Resolution: 10 ml Burette: 1/10000;20 ml Burette: 2/10000
  • Resolution: 1/10000
  • Charging speed: 55±10 s
Potentiometric titrator LMPT-303
  • Burette Repeatability: 0.2%
  • Burette Accuracy: 10 ml Burette: ±0.025 ml;20 ml Burette: ±0.035 ml
  • Burette Resolution: 10 ml Burette: 1/10000;20 ml Burette: 2/10000
  • Resolution: 1/30000
  • Charging speed: 55±10 s
Potentiometric titrator LMPT-304
  • Burette Repeatability: 0.2%
  • Burette Accuracy: 10 ml Burette: ±0.025 ml;20 ml Burette: ±0.035 ml
  • Burette Resolution: 10 ml Burette: 1/10000;20 ml Burette: 2/10000
  • Resolution: 1/30000
  • Charging speed: 55±10 s

Potentiometric Titrator LMPT-401

  • Titration analysis repeatability: 0.002
  • Allowable error of titration capacity: 15ml burette: ±0.025ml; 25ml burette: ±0.035ml
  • Burette resolution: 15ml burette: 1/20000; 25ml burette: 1/10000
  • Titration volume accuracy: 0.0001ml
  • Drive resolution: 1/30000

Potentiometric Titrator LMPT-402

  • Titration analysis repeatability: 0.002
  • Allowable error of titration capacity: 15ml burette: ±0.025ml; 25ml burette: ±0.035ml
  • Burette resolution: 15ml burette: 1/20000; 25ml burette: 1/10000
  • Titration volume accuracy: 0.0001ml
  • Drive resolution: 1/30000