Ask An Expert

We will Follow up with you within 24 hours.

Potentiometric Titrator LMPT-301

Potentiometric titrator LMPT-301 offers an accurate measurement in evaluating the amount of solute in a solution. The device has an LCD screen setup for displaying data and easy recording of the measured values. It performs the titration method without any error due to the high-resolution interface which gives high precision and accuracy throughout the process. It can be used even with auto set i.e. preset endpoint titration (SET) and manual titration(MAT) according to the need for a preferable outcome.

Catalog

Specifications

pH Range 0 to 14.00 pH
pH Resolutions 0.01 pH
pH Accuracy ±0.03 pH
mV Range 0 to ±1400 mV
mV Resolutions 1 mV
mV Accuracy mv: ±5 mV
Fluctuation ±0.01pH /3h
Power supply AC 220 V ±22 V (50±1Hz)
Dimension 300×235×100 mm
weight 3 kg

Pricing

Product Price Unit Action
Potentiometric Titrator LMPT-301 $1,692.00 Pack of 1

Features

The LCD display is present that offers clear visible measured values to note down the data
Automatic and manual titration mode can be set up for the desired processes
The magnetic stirrer is accompanied by the product for carrying out experiments
Volume measurement can be done manually by the provided glass burette
It can measrure the samples within the pH range of 0 to 14.00 pH

Standard Accessories

Platinum electrode silver electrode pH Electrode double bridge reference electrode pH Buffer Powders (4.01, 7.00, 10.01) Stirrer

Applications

Potentiometric titrator provides results which are based on analysis methods that are highly important in the field of electrochemistry and are commonly used for the determination of different organic and inorganic ions in various areas such as process control and environmental, industrial, agricultural analysis and also medicinal drug analysis.

Similar Products

Potentiometric Titrator LMPT-402

  • Titration analysis repeatability: 0.002
  • Allowable error of titration capacity: 15ml burette: ±0.025ml;25ml burette: ±0.035ml
  • Burette resolution: 15ml burette: 1/20000;25ml burette: 1/10000
  • Titration volume accuracy: 0.0001ml
  • Drive resolution: 1/30000

Potentiometric Titrator LMPT-303

  • Burette Repeatability: 0.2%
  • Burette Accuracy: 10 ml Burette: ±0.025 ml;20 ml Burette: ±0.035 ml
  • Burette Resolution: 10 ml Burette: 1/10000;20 ml Burette: 2/10000
  • Resolution: 1/30000
  • Charging speed: 55±10 s

Potentiometric Titrator LMPT-401

  • Titration analysis repeatability: 0.002
  • Allowable error of titration capacity: 15ml burette: ±0.025ml;25ml burette: ±0.035ml
  • Burette resolution: 15ml burette: 1/20000;25ml burette: 1/10000
  • Titration volume accuracy: 0.0001ml
  • Drive resolution: 1/30000
Potentiometric Titrator LMPT-304
  • Burette Repeatability: 0.2%
  • Burette Accuracy: 10 ml Burette: ±0.025 ml;20 ml Burette: ±0.035 ml
  • Burette Resolution: 10 ml Burette: 1/10000;20 ml Burette: 2/10000
  • Resolution: 1/30000
  • Charging speed: 55±10 s
Potentiometric Titrator LMPT-302
  • Burette Repeatability: 0.2%
  • Burette Accuracy: 10 ml Burette: ±0.025 ml;20 ml Burette: ±0.035 ml
  • Burette Resolution: 10 ml Burette: 1/10000;20 ml Burette: 2/10000
  • Resolution: 1/10000