Ask An Expert

We will Follow up with you within 24 hours.

Ion Chromatography LMICS-A100

Ion Chromatography LMICS-A100 is designed with a bipolar conductivity detector to improve instrument detection performance and stability. Boasts a modular design coupled with advanced circuit technology. It provides a flow range spanning from 0.001 to 9.999 ml/min and has a detection range spanning from 0 to 35,000 µS/cm. It is exclusively crafted for the separation, identification, and quantification of ions within a sample.

Catalog

Specifications

Ion Chromatographic Pump High pressure and low pulse double plunger tandem advection pump, 35 MPa (PEEK), (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 %, 0.001 to 9.999 ml/ min, 0.001 to 9.999 ml/ min, ≤ 0.5%
Conductivity detector Temperature Control and Bipolar Conductivity Detector, Bipolar conductivity detection, ≤ 0.8 µL, 0 to 35000 µS/ cm, ≤ 0.0020 nS/ cm, -6000 to +6000 mV (adjustable), ≤ 0.05 % F.S., ≤ 3 % FS/ 30 min, Room temperature +5 to 60°C (41 to 140°F), ± 0.01°C, 10 MPa, ≥ 103, ≥ 0.999, ≤ 1.0 %, ≤ 1.0 %, Cl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml
Flow system Made of PEEK materials, PEEK material, 5000 psi pressure, independent automatic collection, and flow function
Degassing Device 300 µl, 7.5 ml, 10 ml/ min, Degassing 90 % at 1ml/ min, 1
Built-in Eluent Generator KOH/ NaOH, 0.1 to 100 mM, 0.1 mM, 0.1 to 3.0 ml/ min, 20 MPa, 5 MPa
Power supply 150 W
Dimension 350 × 470 × 650 mm
Net weight 34 kg
Gross weight 40 kg

Pricing

Product Price Unit Action
Ion Chromatography LMICS-A100 $37,540.00 Pack of 1

Features

Featuring a gradient elution system, efficiently detects small molecules in complex samples
Incorporate temperature control for optimal analysis conditions
Includes automated components and software to streamline analysis
Built-in low-pressure degassing technology to remove bubble interference
Automated self-regenerating electrolytic microfilm suppressor
Enhanced with standard dilution function that saves time, labor, and costs
RS232 and USB interfaces

Standard Accessories

Ion Chromatography host:1
High-pressure advection pump:1
Conductivity detector:1
Anion column:1
Anion guard column:1
Suppressor:1
Chromatography workstation:1
Column thermostat system:1
Spare parts kits :1
Vacuum degassing pump:1
Sand core filtration devices:1
Pretreatment column:20
0.22 µm syringe filter:200
Eluent generator:1

Optional Accessories

Autosampler (20 samples)
Autosampler (54 samples)
Autosampler (108 samples)
Anion column
Guard column
Anion suppressor
Spare parts kits

Applications

Ion Chromatography finds application in various scientific and industrial fields such as Environmental Monitoring, Pharmaceutical Analysis, Research Laboratories, and more.

Similar Products

Ion Chromatography LMICS-A101

  • Ion Chromatographic Pump: High pressure and low pulse double plunger tandem advection pump, 35 MPa (PEEK), ≤ 0.1 MPa, (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 %, 0.001 to 9.999 ml/ min, ≤ 0.5%
  • Conductivity detector: Temperature Control and Bipolar Conductivity Detector, Bipolar conductivity detection, ≤ 0.8 µL, 0 to 45000 µS/ cm, ≤ 0.0020 nS/ cm, -6000 to +6000 mV (adjustable), ≤ 0.05 % F.S., ≤ 3 % FS/ 30 min, Room temperature +5 to 60°C (41 to 140°F), ± 0.01°C, 10 Mpa, ≥ 103, ≥ 0.999, ≤ 1.0 %, ≤ 1.0 %, Cl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml
  • Flow system: Made of PEEK materials, PEEK material, 5000 psi pressure, independent automatic collection, and flow function
  • Power supply: 150 W
  • External dimension: 350 × 470 × 510 mm

Ion Chromatography LMICS-A102

  • Ion Chromatographic pump: High pressure and low pulse double plunger tandem advection pump, 35 MPa (PEEK), ≤ 0.1 Mpa, (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min ≤ 2 %, 0.001 to 9.999 ml/ min, ≤ 0.5 %
  • Numerical control and electromagnetic injection: 35 Mpa, PEEK, By Stepper motor, DC 24 V
  • Column heater: Room temperature 20 to 60°C (68 to 140°F), ± 0.01°C, ± 2°C, ≤ 1°C/ h
  • Flow system: Made up of PEEK material, PEEK material pressure 5000 psi, independent automatic collection, and flow function
  • Thermal buffer system for Eluent: 25 to 40°C (77 to 104°F)