Ion Chromatography LMICS-A102 features a temperature-controlled bipolar conductivity detector, improving detection performance and instrument stability. Employs a distinctive dual-channel design for independent cation and anion analysis, enabling simultaneous interference-free detection. It provides a flow range spanning from 0.001 to 9.999 ml/min. It is exclusively crafted for the separation, identification, and quantification of ions within a sample.

Catalog Send Mail Whatsapp

Specifications

Ion Chromatographic pump High pressure and low pulse double plunger tandem advection pump, 35 MPa (PEEK), ≤ 0.1 Mpa, (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min ≤ 2 %, 0.001 to 9.999 ml/ min, ≤ 0.5 %
Numerical control and electromagnetic injection 35 Mpa, PEEK, By Stepper motor, DC 24 V
Column heater Room temperature 20 to 60°C (68 to 140°F), ± 0.01°C, ± 2°C, ≤ 1°C/ h
Flow system Made up of PEEK material, PEEK material pressure 5000 psi, independent automatic collection, and flow function
Thermal buffer system for Eluent 25 to 40°C (77 to 104°F)
Degassing device Built-in low pressure, (-) 70 kPa, 10 ml/ min, 30 µl, 10 ml/ min 90 %
Digital temperature and control detection system Temperature-control and Bipolar conductivity detector, Bipolar conductivity detection, ≤ 0.8 µl, 0 to 50000 µS/ cm, -6000 to +6000 mV (adjustable), Room temperature 5 to 60°C (41 to 140°F), ± 0.01°C, 10 Mpa, ≥ 103, ≥ 0.999, ≤ 1.0 %, ≤ 1.0 %
Eluent generator KOH/ NaOH, 0.1 to 100 mM, 0.1 mM, 0.1 to 3.0 ml/ min, 20 Mpa, 5 Mpa
Power 150 W
Power supply DC 220 V, 60 Hz
Dimension 500 × 500 × 760 mm
Net weight 48 kg
Gross weight 73 kg

Pricing

Product Price Unit Action
Ion Chromatography LMICS-A102 $ 66875 Pack of 1

Features

Built-in low-pressure degassing technology to remove bubble interference
Enhanced with an Ion chromatographic pump with a maximum pressure of 35 MPa
Equipped with a smart (PEEK) flow path system featuring an automatic cleaning mode
Sophisticated thermal buffer system for the eluent
Automated sample injection
Minimizes interference and ensures accurate measurements
Captures and presents analytical results
Ensures comprehensive ion analysis by suppressing unwanted ions
Intuitive control panel for easy operation and monitoring

Optional Accessories

Anion column Guard column Anion Suppressor UV detector Ampere detector Autosampler (108) samples

Applications

Ion Chromatography is versatile and spans various industries such as Environmental Analysis, Pharmaceutical Industry, Research and Development, and more.

Auto Sampler

Display: 7-inch touch control, color LCD
Injection mode: X-Y-Z three-axis operational mode
Sampling mode: Full quantitative loop sampling
Number of injection units: 2 ml × 120 units
Repeat injection: 1 to 5 times (optional)
Injection volume: 25 to 500 µl
Sample syringe capacity: 5 ml maximum
Pipe material: Plastic
Circulation time: ≤ 6 minutes
Injection accuracy: ≤ 0.5 %
Residual sample: ≤ 0.05 %
Control system: ARM STM32 series of 32 bits embedded
Embedded: LQFP100
Communication mode: RS232
Dimension (L×W×H): 400 × 540 × 260 mm

Selection Guide

Ion Chromatography LMICS-A102 is designed for high-accuracy separation and detection of anions, cations, organic acids, and other polar substances, making it suitable for applications in environmental monitoring, food safety, pharmaceuticals, and chemical research. Backed by research-based usage in water quality testing, residue analysis, and ionic composition studies, this model is ideal for laboratories needing accurate quantitative analysis. Its certifications, such as ISO and CE, ensure reliability and regulatory compliance, which is crucial for accredited labs. Customers seeking consistent performance, low detection limits, and broad application flexibility will find this model a dependable choice.

Similar Products

Ion Chromatography LMICS-A101

  • Ion Chromatographic Pump: High pressure and low pulse double plunger tandem advection pump, 35 MPa (PEEK), ≤ 0.1 MPa, (0.2 to 0.5) ml/ min ≤ 3 %(0.5 to 1.0) ml/ min ≤ 2 %> 1.0 ml/ min 2 %, 0.001 to 9.999 ml/ min, ≤ 0.5%
  • Conductivity detector: Temperature Control and Bipolar Conductivity Detector, Bipolar conductivity detection, ≤ 0.8 µL, 0 to 45000 µS/ cm, ≤ 0.0020 nS/ cm, -6000 to +6000 mV (adjustable), ≤ 0.05 % F.S., ≤ 3 % FS/ 30 min, Room temperature +5 to 60°C (41 to 140°F), ± 0.01°C, 10 Mpa, ≥ 103, ≥ 0.999, ≤ 1.0 %, ≤ 1.0 %, Cl ≤ 0.0005 ug/ mlBrO3 ≤ 0.001 ug/ mlLi+ ≤ 0.001 ug/ ml
  • Flow system: Made of PEEK materials, PEEK material, 5000 psi pressure, independent automatic collection, and flow function
  • Power supply: 150 W
  • External dimension: 350 × 470 × 510 mm

$ 54625 / Pack of 1

Ion Chromatography LMICS-A100

  • Ion Chromatographic Pump: High pressure and low pulse double plunger tandem advection pump, 35 MPa (PEEK), (0.2 to 0.5) ml/ min ≤ 3 %(0.5 to 1.0) ml/ min ≤ 2 %> 1.0 ml/ min 2 %, 0.001 to 9.999 ml/ min, 0.001 to 9.999 ml/ min, ≤ 0.5%
  • Conductivity detector: Temperature Control and Bipolar Conductivity Detector, Bipolar conductivity detection, ≤ 0.8 µL, 0 to 35000 µS/ cm, ≤ 0.0020 nS/ cm, -6000 to +6000 mV (adjustable), ≤ 0.05 % F.S., ≤ 3 % FS/ 30 min, Room temperature +5 to 60°C (41 to 140°F), ± 0.01°C, 10 MPa, ≥ 103, ≥ 0.999, ≤ 1.0 %, ≤ 1.0 %, Cl ≤ 0.0005 ug/ mlBrO3 ≤ 0.001 ug/ mlLi+ ≤ 0.001 ug/ ml
  • Flow system: Made of PEEK materials, PEEK material, 5000 psi pressure, independent automatic collection, and flow function
  • Degassing Device: 300 µl, 7.5 ml, 10 ml/ min, Degassing 90 % at 1ml/ min, 1
  • Built-in Eluent Generator: KOH/ NaOH, 0.1 to 100 mM, 0.1 mM, 0.1 to 3.0 ml/ min, 20 MPa, 5 MPa

$ 46925 / Pack of 1

Frequently Asked Questions

1 What is an Ion Chromatograph?

An Ion Chromatograph is an apparatus designed to separate and analyze ions in a liquid sample.

2 How does an Ion Chromatograph work?

It separates and detects ions in a liquid sample using an ion-exchange column and a detector.

3 What kind of maintenance does Ion Chromatograph require?

Regular maintenance includes replacing columns, cleaning detectors, calibrating the system, and preparing fresh eluents.

4 How is Ion Chromatograph used in water testing?

It is used in water testing to detect and measure common anions and cations such as fluoride, nitrate, and calcium to ensure water quality and regulatory compliance.

5 Can Ion Chromatograph be used in food and beverage analysis?

It is widely used in the food and beverage industry to analyze ingredients, preservatives, and mineral content like sodium and phosphate.

6 How does Ion Chromatograph help in pharmaceutical analysis?

It is essential in pharmaceuticals for analyzing ionic impurities, counter-ions, and excipients in raw materials and finished drug products.

7 How does Ion Chromatograph assist in forensic science?

It assists forensic labs by detecting and quantifying ionic substances like explosive residues, drugs, and poisons in crime scene samples.

8 Can Ion Chromatograph be used in petrochemical analysis?

It is used in the petrochemical industry to analyze process water, cooling fluids, and ionic contaminants that can affect refining operations.

9 Can Ion Chromatograph be used in marine science?

It is used in marine research to study the ionic composition of seawater and its effect on marine ecosystems.

10 Can Ion Chromatograph be used in pesticide residue analysis?

It is used to detect ionic breakdown products of pesticides in agricultural samples, helping assess environmental and food safety risks.