HPLC System LMHLS-A205

HPLC System LMHLS-A205 is an analytical system equipped with high-pressure constant flow pump. Features two solvent channels for precise and stable solvent delivery. Comes with a UV-Visible detector capable of detecting wavelengths in the 190 to 800 nm range. Designed with an automatic calibration function that enhances accuracy by optimizing deuterium lamp energy. Built with EMC electromagnetic compatibility to minimize external interference, ensuring reliable performance. Our HPLC system is ideal for laboratory and industrial chromatography applications, delivering consistent and accurate analytical results.

Catalog Send Mail Whatsapp

Specifications

Pump Type High pressure constant flow pump
Solvent Channel 2
Flow Range 0.001 to 10.000 mL/min
Pump Flow Accuracy Up to ± 0.3 %
Pump Flow Stability Up to 0.06 %
Maximum Operating Pressure 120 MPa
Pump Display Pressure Error Up to 1.0 %
Pump Pressure Limit Alarm Range 0 to 90 MPa
Pump Gradient Mixing Accuracy ± 0.5%
Pump Gradient Mixing Precision Up to 0.1%
Pump Gradient Composition Range 0 to 100%
Pump Gradient Composition Increment 0.01%
Pump Power Consumption 200 W
Pump Power Supply 110 to 220 V, 50 to 60 Hz
Pump Dimension (W×D×H) 540 × 380 × 180 mm
Pump Packing Dimension (W×D×H) 600 × 440 × 380 mm
Pump Net Weight 13 kg
Pump Gross Weight 15 kg
Detector Type UV-visible detector
Detector Wavelength Range 190 to 800 nm
Detector Wavelength Repeatability ± 0.1 nm
Detector Band Width 8 nm
Detector Linearity Range ≥ 2.5 AU (customizable: 3.0 AU)
Detector Dynamic Short-term Noise ± 2.5 × 10⁻⁵ AU
Detector Dynamic Baseline Drift ± 1 nm
Minimum Detectable Concentration Up to 1.0 × 10⁻⁹ g/mL
Detector Light Source Deuterium lamp
Detection Pool Withstand Pressure 10.3 MPa
Detector Power Consumption 100 W
Detector Power Supply 110 V / 220 V, 50 / 60 Hz
Detector Dimension (W×D×H) 600 × 380 × 180 mm
Detector Packing Dimension (W×D×H) 600 × 440 × 380 mm
Detector Net Weight 13 kg
Detector Gross Weight 15 kg
Autosampler Temperature Range Room temperature
Autosampler Injection Method Full loop, non-destructive, destructive injection
Autosampler Injection Range 0 to 100 µL
Autosampler Sample Capacity 210 bits (1 mL vial); 120 bits (2 mL vial); 72 bits (4 mL vial); Dual 96-well plates (supports base magnetic plate option)
Autosampler Sample Residue Less than 0.002%
Autosampler Repeatability Less than 0.3%
Autosampler Injection Speed “Extremely fast injection” mode, fastest injection time: 1 sec
Autosampler Packing Dimension (W×D×H) 600 × 440 × 380 mm
Autosampler Net Weight 13 kg
Autosampler Gross Weight 15 kg
Standard Software Kromstation workstation
Accessories Packing Dimension (W×D×H) 500 × 360 × 300 mm
Accessories Net Weight 7 kg
Accessories Gross Weight 8 kg

Pricing

Product Price Unit Action
HPLC System LMHLS-A205 $ 36112.5 Each of 1

Features

Rapid sampling rate

Dual signal output

Cooled sample tray

Superior stability and precision

Kromstation control software

Standard Accessories

Accessory

Quantity

Unit

High Pressure Constant Flow Pump

1

Piece

UV-Vis Detector (exclude sample cell)

1

Piece

sample cell

1

Piece

Autosampler

1

Piece

solvent Bottle Tray

1

Piece

Kromstation Workstation

1

Piece

system tool kits

1

Piece

Mobile phase bottles (1000ML)

2

Pieces

Optional Accessories

Column Oven 

Applications

HPLC System LMHLS-A205 is ideal for precise analysis in pharmaceuticals, biochemistry, and environmental testing. It is used for separating and quantifying compounds in drugs, proteins, food samples, and chemical formulations, as well as detecting pollutants and metabolites in research and industrial applications.

Similar Products

HPLC System LMHLS-A100

  • Maximum Pressure: 42 MPa
  • Flow Range: 0.001 to 10.000 mL/min
  • Flow Accuracy: ± 0.5%
  • Flow Precision: ≤ 0.2%
  • Pressure Fluctuation: ≤ 1%

$ 49000 / Each of 1

HPLC System LMHLS-A101

  • Flow Rate: 0.001 to 10.000 mL/min
  • Accuracy: ±0.2%
  • Precision: RSD less than or equal to 0.075%
  • Max Pressure: 45 MPa (up to 5.000 mL/min), 20 MPa (above 5.001 mL/min)
  • Pressure Accuracy: ±3% or ±0.5 MPa

$ 27437.5 / Each of 1

HPLC System LMHLS-A200

  • Flow Rate Range: 0.001 to 10.000 ml/min
  • Maximum Pressure: 40 MPa
  • Maximum Injection Volume: 100 μl (extendable to 1000 μl)
  • Sampler Temperature: 1 to 45°C
  • Sampler Capacity: 120×2 ml vial, compatible with 96-well plates

$ 34982.5 / Each of 1

HPLC System LMHLS-A204
  • Flow Rate Range: 0.001 to 10.000 ml/min
  • Maximum Operating Pressure: 45 MPa / 62 MPa / 70 MPa
  • Maximum Injection Volume: 100 µL
  • Temperature Range: 1°C to 45°C
  • Injector Capacity: 120 × 2ml vials, compatible with 96-well plates

$ 60062.5 / Each of 1

HPLC System LMHLS-A203
  • Flow Rate Range: 0.001to10.000 ml/min
  • Maximum Operating Pressure: 45 MPa / 62 MPa
  • Maximum Injection Volume: 100 μl
  • Temperature Range: 1 to 45°C
  • Injector Capacity: 120 × 2 ml vials, 96-well plates compatible

$ 51237.5 / Each of 1

HPLC System LMHLS-B100

  • Flow Rate Range: 0.001 to 9.999 mL/min
  • Flow Rate Error: Less than or equal to 0.5%
  • Infusion Mode: Micro-volume double plunger
  • Maximum Infusion Pressure: 6000 Psi (42 MPa)
  • Column Capacity: 2 × 250 mm chromatographic columns

$ 21000 / Each of 1

HPLC System LMHLS-A202

  • Flow Rate Range: 0.001 to 10.000 ml/min
  • Maximum Operating Pressure: 70 MPa
  • Maximum Injection Volume: 30 µL
  • Temperature Range: 1 to 45℃
  • Injector Capacity: 120 × 2 mL vials, 96-well plates compatible

$ 80741.25 / Each of 1

HPLC System LMHLS-A201

  • Flow Rate Range: 0.001 to 10.000 ml/min
  • Maximum Operating Pressure: 45 MPa / 62 MPa
  • Maximum Injection Volume: 100 µl
  • Maximum Column Capacity: 300 mm column, 3 columns
  • Temperature Range: 1 to 45°C

$ 51237.5 / Each of 1

Frequently Asked Questions

1 What is a calibration curve in HPLC?

It is a graph that plots the known concentrations of a standard compound versus the detector response.

2 Is pH important in HPLC?

The pH of the mobile phase plays a crucial role in analyzing ionizable compounds.

3 Can HPLC be used for biomolecule analysis?

It is widely used for separation and analysis of biomolecules such as proteins, peptides and nucleic acids.

4 What is meant by elution strength in HPLC?

It refers to the ability of the mobile phase to elute the analytes from the stationary phase.

5 What is a HPLC?

A HPLC is an apparatus designed to separate, identify and quantify the components of a complex mixture.

6 On what principle is HPLC based on?

It is based on the differential interactions between the analytes and the stationary phase.

7 What is meant by resolution in HPLC?

Resolution refers to the ability of the system to separate two peaks.

8 What is meant by retention time in case of HPLC?

It is the time taken by specific compound to travel through the HPLC column and reach the detector.