Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Fluorescence Spectrophotometer LMFSP-A102

Fluorescence Spectrophotometer LMFSP-A102 offers wavelength range of 200 to 900 nm. It features horizontal slit design for high luminous detection and signal-to-noise ratio. Equipped with photoelectric multiplier tube detector, it ensures reliable signal measurement and high sensitivity across multiple ranges. Incorporates advanced software offering 3D fluorescence scanning for enhanced molecular analysis and visualization. Our Spectrophotometer enables detection, characterization, and monitoring of chemicals and biomolecules.

Catalog Send Mail Whatsapp

Specifications

Wavelength Range 200 to 900 nm
Bandwidth 1nm/2nm/5nm/10nm/20nm
Wavelength Accuracy ±0.4nm
Wavelength Repeatability Less than or equal to 0.2nm
Signal-To-Noise Ratio Greater than or equal to 350(P-P) or Greater than or equal to 1000(RMS)
Minimum Sample Size 0.5mL
Maximum Wavelength Scan Speed 60000 nm/min
Excitation Source Xenon lamp
Limit Less than or equal to 5×10-11 g/ml
Linearity γ greater than or equal to 0.995
Peak Repeatability Less than or equal to 1.5%
Filter Build in Octave filter
Photometric Quantity Range -9999 to 9999
Response Time 0.02/0.1/0.5/1/2/4/8 s, Auto adjust
Data Transmission USB2.0
Power Consumption 200W
Power Supply AC 220V/50Hz or 110V/60Hz
Dimension 610×460×365 mm
Net Weight 21kg
Gross Weight 26kg

Pricing

Product Price Unit Action
Fluorescence Spectrophotometer LMFSP-A102 $ 29750 Each of 1

Features

Water Raman SNR

Synchronous scanning

Xenon light source

Frequency filter

Optical gate

Optional Accessories

Model No

Accessory

Unit

Quantity

LMFSP-A102-M1Multi-function adapter

Each

1

LMFSP-A102-M2Membrane sample holder

Each

1

LMFSP-A102-M3200µL microcentrifuge tube holder

Each

1

LMFSP-A102-P1Powder sample holder

Each

1

LMFSP-A102-P2Peltier temperature control holder

Each

1

LMFSP-A102-S1Sample cell jacket

Each

1

LMFSP-A102-U1Up conversion laser head holder

Each

1

LMFSP-A102-F2Fluorescence Quantum Yield accessory

Each

1

LMFSP-A102-C1500 µL Microscale quartz cuvette

Each

1

LMFSP-A102-C2200 µL Microscale quartz cuvette

Each

1

LMFSP-A102-C3Glass cuvette 4-side-clear

Set

2

LMFSP-A102-C4Quartz cuvette 4-side-clear

Set

2

LMFSP-A102-H110mm cell holder adapter

Each

1

LMFSP-A102-F1Double frequency filter

Each

8

LMFSP-A102-A1Auto Polarization Filter (Visible:400 to 700nm)

Each

1

LMFSP-A102-A2Auto Polarization Filter (UV-visible: 250 to 1000nm)

Each

1

Applications

Fluorescence Spectrophotometer LMFSP-A102 enables qualitative and quantitative fluorescence analysis, characterization, and monitoring across research, healthcare, environmental, industrial, and food sectors.

Similar Products

Fluorescence Spectrophotometer LMFSP-A101

  • Excitation Wavelength: 200nm to 900nm
  • Emission Wavelength: 200nm to 900nm
  • Excitation Slit: 10nm
  • Emission Slit: 10nm
  • Wavelength Accuracy: ±0.1nm

$ 13600 / Each of 1

Fluorescence Spectrophotometer LMFSP-A100

  • Wavelength Range: 250 to 700nm
  • Wavelength Accuracy: ±1 nm
  • Wavelength Repeatability: Less than or equal to 0.5 nm
  • Detection Sensitivity: Signal-to-noise ratio greater than or equal to 150
  • Measurement Source: Raman peak of water in a 1 cm quartz cuvette

$ 8625 / Each of 1

Frequently Asked Questions

1 What is Fluorescence Spectrophotometer LMFSP-A102?

Fluorescence Spectrophotometer LMFSP-A102 is an advanced instrument used to analyze the luminescence of samples for research and quality control.

2 How does the Fluorescence Spectrophotometer LMFSP-A102 work?

The Fluorescence Spectrophotometer LMFSP-A102 excites samples with a xenon light source and measures the emitted fluorescence using sensitive detectors, allowing reliable measurement and analysis of sample fluorescence.

3 Can the Fluorescence Spectrophotometer LMFSP-A102 measure fluorescence quantum yield?

Yes. A dedicated Quantum Yield accessory is available to calculate the fluorescence quantum yield of samples easily.

4 Can the Fluorescence Spectrophotometer LMFSP-A102 handle small sample volumes?

Yes. Its cell holder and optics are designed to work with very small sample volumes, reducing reagent costs and preparation time.

5 What type of light source does Fluorescence Spectrophotometer LMFSP-A102 use?

It uses a 150 W xenon lamp as the excitation source, providing stable and intense illumination for high-sensitivity detection.

6 Does the Fluorescence Spectrophotometer LMFSP-A102 allow bandwidth adjustment?

Yes. Both excitation and emission slits are adjustable, allowing flexible control of spectral resolution.

7 Which method is used by the Fluorescence Spectrophotometer LMFSP-A102 to check the fluorescence of the samples?

Fluorescence is measured by excitation or emission dual monochromator spectroscopy.

8 What is a Fluorescence Spectrophotometer?

A Fluorescence Spectrophotometer is an apparatus designed to measure the fluorescence emitted by a sample after it absorbs light of a specific wavelength.

9 How does a Fluorescence Spectrophotometer work?

It works by illuminating a sample with light, causing it to emit fluorescence, which is then measured to analyze the properties of the sample.

10 Can Fluorescence Spectrophotometer be used for quantitative analysis?

It can be used for quantitative analysis by measuring the fluorescence intensity of a sample and comparing it to a calibration curve created from standards with known concentrations.

11 How is Fluorescence Spectrophotometer used in biological research?

It is used in biological research to study molecular interactions, detect specific proteins, nucleic acids, and biomarkers, and analyze cellular processes in live or fixed samples.

12 Can Fluorescence Spectrophotometer be used for drug discovery?

It is commonly used in drug discovery to screen for potential drug candidates by monitoring interactions between compounds and biomolecules, such as proteins or DNA, in real time.

13 Can Fluorescence Spectrophotometer be used for environmental monitoring?

It is used to detect pollutants, toxins, and organic compounds in water, soil, and air samples by measuring their fluorescence properties.

14 What role does Fluorescence Spectrophotometer play in medical diagnostics?

It is used in medical diagnostics to detect specific biomarkers or disease-related molecules, helping in early disease detection and monitoring treatment progress.

15 Can Fluorescence Spectrophotometer be used in food and beverage analysis?

It is used in food and beverage analysis to detect contaminants, additives, and analyze the quality of substances like oils, proteins, and vitamins based on their fluorescence properties.

16 Can Fluorescence Spectrophotometer be used in forensic science?

It is used in forensic science to analyze trace evidence, such as bodily fluids, fibers, and chemicals, by detecting specific fluorescent markers in the samples.

17 What role does Fluorescence Spectrophotometer play in cellular imaging?

It is used in cellular imaging to analyze fluorescence emitted from specific cellular components, allowing researchers to study cellular structures, processes, and dynamics in live cells.