Get Quote

Contact us now to receive a detailed quotation.

Ductless Fume Hood LMDL-A102

Ductless Fume Hood LMDL-A102 is configured with constant airflow technology to offer protection against airborne biological agents for ease of operation. It features an exhaust volume of 990 m³/h working within airflow velocity of 0.3 to 0.8 m/s with low power consumption. Employed with transparent side UV-resistant safety glass for perfect examination of the inside sample without any disturbance. Scratch-free high-quality stainless steel ensures corrosion resistance and long service life.

Catalog Send Mail Whatsapp

Specifications

Cabinet Size 59 Inches
Airflow Velocity 0.3 to 0.8 m/s
Exhaust Volume 990 m³/h
Glass Door Thickness Front Glass: 5 mm, Motorized
Display Digital LED Display
Max. Door Opening Height 520 mm
Working Surface Height 750 mm
Filter Active Carbon filter
Blower Centrifugal blower
UV Lamp 30 W
Illumination Lamp LED Lamp (16 W)
Illumination ≥ 400 Lux
Noise ≤ 68 dB
Power Consumption 500 W
Power Supply AC 220 / 110 V ± 10 % ; 50 / 60 Hz
Internal Dimension 1380 × 730 × 745 mm
External Dimension 1500 × 840 × 2150 mm
Gross Weight 290 kg

Features

Designed with digital LED screen displayed all parameters of operational status
Energy-efficient microprocessor controller ensures temperature and humidity control
Supplied with resistance to weak acid and alkali
Improved backside air compensation, to avoid turbulence in a work area
Built-in centrifugal blower with an adjustable air speed of about 9 levels
Configured with efficient UV sterilization with 253.7 nm emission
Integrated with activated carbon filter with a working time of 3500 hrs
Include memory function for power-failure conditions
Chemical-resistant phenolic resin workbench
Reduced contamination risk with anti-bacteria powder-coated steel body

Standard Accessories

Model NoNameQuantityImage
LFHC-01Activated Carbon Filter1 
LFHC-06Base Stand1 
LFHC-07Centrifugal Blower1 
LFHC-12Exhaust Duct1 (4 meter) 
LFHC-16Foot switch1 
LFHC-18Gas Tap1 
LFHC-22LED Lamp1 (16 W) 
LFHC-29UV Lamp2 
LFHC-32Water Sink1 
LFHC-33Water Tap1 
LFHC-34Waterproof Socket1 

Applications

It is used to protect lab samples and equipment from contamination. Commonly used in medical laboratories, medical industrial services, and food processing plants.

Similar Products

Ductless Fume Hood LMDL-A103

  • Cabinet Size: 70 Inches
  • Airflow Velocity: 0.3 to 0.8 m/s
  • Exhaust Volume: 1210 m³/h
  • Glass Door Thickness: Front Glass: 5 mm, Motorized
  • Display: Digital LED Display

Ductless Fume Hood LMDL-A100

  • Cabinet Size: 39 Inches
  • Airflow Velocity: 0.3 to 0.8 m/s
  • Exhaust Volume: 630 m³/h
  • Glass Door Thickness: Front Glass: 5 mm, Motorized
  • Display: Digital LED Display

Ductless Fume Hood LMDL-A201

  • Cabinet Size: 47 Inches
  • Airflow Velocity: 0.25 to 0.35 m/s
  • Exhaust Volume: 105 m³/h
  • Glass Door Thickness: Front window: Manual
  • Display: LCD Touch Panel
Ductless Fume Hood LMDL-A200
  • Cabinet Size: 39 Inches
  • Airflow Velocity: 0.25 to 0.35 m/s
  • Exhaust Volume: 105 m³/h
  • Glass Door Thickness: Front window: Manual
  • Display: LCD Touch Panel
Ductless Fume Hood LMDL-A203
  • Working Surface Height: 900 mm
  • Maximum door opening height: 650 mm
  • Airflow Velocity: 0.4 to 0.6 m/s
  • Exhaust Volume: 547 m³/h
  • Front Window: Acrylic window; Manual; Reversal design

Ductless Fume Hood LMDL-A101

  • Cabinet Size: 47 Inches
  • Airflow Velocity: 0.3 to 0.8 m/s
  • Exhaust Volume: 780 m³/h
  • Glass Door Thickness: Front Glass: 5 mm, Motorized
  • Display: Digital LED Display

Ductless Fume Hood LMDL-A202

  • Cabinet Size: 59 Inches
  • Airflow Velocity: 0.25 to 0.35 m/s
  • Exhaust Volume: 325 m³/h
  • Glass Door Thickness: Front window: Manual
  • Display: LCD Touch Panel

Frequently Asked Questions

1 What is a Ductless Fume Hood?

A Ductless Fume Hood is an apparatus designed to filter hazardous fumes, vapors, and particles from the air, then recirculate clean air back into the workspace.

2 How does a Ductless Fume Hood work?

It works by drawing in contaminated air, filtering it through specialized filters, and recirculating purified air.

3 What kind of maintenance does Ductless Fume Hood require?

Routine maintenance includes checking airflow, inspecting filters, and ensuring proper operation of alarms and electronics.

4 What is the difference between a Ducted Fume Hood and a Ductless Fume Hood?

A Ducted Fume Hood vents air outside the building through ductwork, whereas a Ductless Fume Hood filters and recirculates air within the room.

5 Can Ductless Fume Hood be used for chromatography solvent handling?

It is commonly used to handle solvents like hexane or methanol in sample prep and waste collection.

6 Can Ductless Fume Hood be used in environmental testing labs?

It is ideal for processing soil, air, or water samples with VOCs and other light chemical exposure.

7 Can Ductless Fume Hood be used for cosmetic product development?

It is well-suited for formulating lotions, perfumes, and other cosmetic products involving alcohols or light solvents.

8 Is Ductless Fume Hood appropriate for botanical extraction or cannabinoid research?

It is commonly used with ethanol and terpene-rich compounds when properly filtered for volatile organic solvents.

9 Is Ductless Fume Hood suitable for paint, pigment, or ink formulation research?

It is effective at capturing fumes from solvents and colorants during formulation and mixing.

10 Is Ductless Fume Hood appropriate for fragrance or essential oil R&D?

It is well-suited for handling volatile natural compounds.