Dry Bath Incubator LMDRI-C101 offers wide temperature range from 0 to 100℃. It features microcomputer control to maintain stable temperature conditions for sample reactions and preservation tasks. Equipped with interchangeable blocks, it supports ample variety of sample tube sizes and formats. Incorporates an automatic fault detection mechanism with buzzer alerts for immediate attention to system errors. Our Incubator is ideal for heating, incubating, and stabilizing samples for research.

Catalog Send Mail Whatsapp

Specifications

Temperature Setting Range 0 to 100℃
Temperature Control Range RT+5 to 100℃
Temperature Accuracy Less than or equal to ±0.3℃
Temperature Uniformity Less than or equal to ±0.3℃
Heating Time Less than or equal to 12min (from 25℃ to100℃)
Timing Range 1min to 99min59sec/∞
Display Accuracy 0.1℃
Power Consumption 150W
Power Supply AC220V or AC110V, 50/60Hz
Dimensions 260×195×150 mm
Weight 2.5 Kg

Features

LCD display

Simple operation

Quick block replacement

Effortless cleaning

Overheat protection

Compact structure

Optional Accessories

Model No.

Accessory

LMDRI-C101-B1

0.2ml×96 block 

LMDRI-C101-B2

0.5ml×54 block

LMDRI-C101-B3

1.5ml×35 block

LMDRI-C101-B4

2.0ml×35 block

LMDRI-C101-B5

0.5ml×15+1.5ml×20 block

LMDRI-C101-B6

0.2ml×96(Elisa plate) block

LMDRI-C101-B7

5ml×24 block

LMDRI-C101-B8

10ml×15 block

LMDRI-C101-B9

15ml×12 block

LMDRI-C101-B10

Round 50ml×6 block

LMDRI-C101-B11

Conical 50ml×6 block

Applications

Dry Bath Incubator LMDRI-C101 ensures heating, incubating, and stabilizing samples for DNA amplification, serum solidification, and electrophoresis preparation in laboratory and research environments.

Similar Products

Dry Bath Incubator LMDRI-C104

  • Temperature Range: RT -20℃ to 100℃
  • Set Temperature Range: 0℃ to 100℃
  • Heating Time: Less than or equal to 20 min (25°C to 100°C)
  • Temperature Accuracy: Less than or equal to ±0.3°C
  • Display Accuracy: 0.1°C

Dry Bath Incubator LMDRI-C113

  • Temperature Range: RT+5 to 160℃
  • Block Quantity: 2
  • Temperature Accuracy: ±0.5℃ at 40℃, ±1℃ at120℃
  • Temperature Uniformity: ±0.5℃
  • Heating Time: Less than or equal to 15min (from 25℃ to 160℃)

Dry Bath Incubator LMDR-B105

  • Temp. Control Range: RT+5℃ ~ 120℃
  • Heating time: ≤ 30 min(from 20 ℃ to 150 ℃)
  • Temperature Control accuracy@100°C: ≤ ±0.5℃
  • Block temp difference@40℃: 0.3℃
  • Block temperature Uniformity: ≤ ±0.5℃
Dry Bath Incubator LMDR-B101
  • Temp. Control Range: -10℃-100℃
  • Heating time: ≤ 15 min(from 20 ℃ to 150 ℃)
  • Temperature Control accuracy@100°C: ≤ ±0.5℃
  • Block temp difference@40℃: 0.3℃
  • Block temperature Uniformity: ≤±0.3℃
Dry Bath Incubator LMDRI-B110
  • Temperature Range: RT -15°C to 100°C
  • Temperature Stability: ±0.5°C
  • Temperature Homogeneity: ±0.5°C
  • Display Accuracy: 0.1°C
  • Heating Time: Less than or equal to 12min

Dry Bath Incubator LMDRI-A101

  • Maximum Temperature: 150℃
  • Temperature Control Range: RT+5℃ to 150℃
  • Temperature Stability at 40℃: ±0.3℃
  • Temperature Stability at 100℃: ±0.5℃
  • Temperature Stability at 120℃: ±1℃

Dry Bath Incubator LMDRI-C114

  • Temperature Range: RT+5 to 130℃
  • Block Quantity: 4
  • Temperature Accuracy: ±0.5℃ at 40℃, ±1℃ at120℃
  • Temperature Uniformity: ±0.5℃
  • Heating Time: Less than or equal to 20min (from 25℃ to 130℃)

Dry Bath Incubator LMDR-B106

  • Temp. Control Range: RT + 5 °C to 160 ℃
  • Temp Accuracy at 40 °C: ± 0.5 °C
  • Temp Accuracy at 120 °C: ± 1 °C
  • Block temperature Uniformity: ± 0.5 °C
  • Display Accuracy: 0.1 °C
Dry Bath Incubator LMDRI-C103
  • Temperature Range: RT +5℃ to 100℃
  • Set Temperature Range: 0℃ to 100℃
  • Heating Time: Less than or equal to 20 min (40°C to 100°C)
  • Temperature Accuracy: Less than or equal to ±0.3°C
  • Display Accuracy: 0.1°C
Dry Bath Incubator LMDRI-C108
  • Temperature Range: RT+5℃ to 110℃
  • Set Temperature Range: 0℃ to 110℃
  • Heating Time: Less than or equal to 20 min (from 25℃ to 110℃)
  • Temperature Accuracy: Less than or equal to ±0.3℃ at 37℃
  • Display Accuracy: 0.1°C

Dry Bath Incubator LMDRI-C107

  • Temperature Range: RT.+5℃ to 130℃
  • Set Temperature Range: 5℃ to 130℃
  • Heating Time: Less than or equal to 20 min (from 25℃ to 130℃)
  • Temperature Accuracy: ±0.5℃ (at 40℃) or ±1℃ (at 120℃)
  • Display Accuracy: 0.1°C

Dry Bath Incubator LMDRI-C109

  • Temperature Range: RT+5℃ to 100℃
  • Set Temperature Range: 0℃ to 100℃
  • Heating Time: Less than or equal to 15min (from 25℃ to 100℃)
  • Temperature Accuracy: Less than or equal to ±0.3℃ at 37℃
  • Display Accuracy: 0.1°C

Dual Temperature Dry Bath Incubator LMDBI-A101

  • Temperature Control Range: -10℃ to 105℃
  • Temperature Setting Range: -10℃ to 105℃
  • Heating Speed: Less than or equal to 15 min
  • Maximum Temperature: 105℃
  • Cooling Speed: Less than or equal to 25 min
Heated Lid Dry Bath Incubator LMHDI-A100
  • Block Temperature Range: R.T. -30℃ to 105℃
  • Temperature Set Range: -10℃ to 105℃
  • Lid Temperature Range: R.T. +5℃ to 110℃
  • Timer: 1s to 99min59sec
  • Block Temperature Accuracy: ±0.5℃
Dry Bath Incubator LMDRI-C106
  • Temperature Range: RT +5℃ to 160℃
  • Set Temperature Range: 5℃ to 160℃
  • Heating Time: Less than or equal to 15min (from 25℃ to 160℃)
  • Temperature Accuracy: ±0.5℃ (at 40℃) or ±1℃ (at 120℃)
  • Display Accuracy: 0.1°C

Frequently Asked Questions

1 What is a Dry Bath Incubator?

A Dry Bath Incubator is an apparatus that uses a solid, heated metal block to incubate samples at precise temperatures.

2 Can Dry Bath Incubator be used for DNA extraction?

It is commonly used for DNA extraction steps such as lysis, protein digestion, and enzyme incubation at controlled temperatures.

3 How is Dry Bath Incubator used in clinical diagnostics?

In clinical labs, it is used to incubate blood, serum, or plasma samples for enzyme assays, coagulation studies, and biochemical tests.

4 Can Dry Bath Incubator be used for enzyme inactivation?

It is frequently used to inactivate enzymes by maintaining high temperatures for a defined period.

5 Is Dry Bath Incubator suitable for thawing frozen samples?

It can quickly and uniformly thaw frozen biological samples like cell lysates, DNA/RNA solutions, or reagents.

6 Can Dry Bath Incubator assist in isothermal amplification methods?

It is suitable for isothermal nucleic acid amplification techniques such as LAMP, which require consistent, fixed temperatures.

7 How does Dry Bath Incubator help in pharmaceutical testing?

In pharmaceutical labs, it is used for drug stability testing, dissolution studies, and incubation of formulations under controlled conditions.

8 Can Dry Bath Incubator be used in food testing laboratories?

It is used in food testing to incubate samples for microbial detection, enzyme activity analysis, and sample digestion processes.

9 How is Dry Bath Incubator used in forensic science?

It is used to incubate DNA samples, accelerate chemical reactions, or maintain sample integrity under controlled conditions.

10 How does Dry Bath Incubator assist in quality control (QC) labs?

It is used in QC labs to perform temperature-dependent tests such as reagent validation, sample incubation, and product consistency checks.