Get Quote
Contact us now to receive a detailed quotation.
Labmate Flame Photometer measures sodium and potassium levels with sensitivity down to 1 ppm. They feature simple interface with digital displays that show real-time data clearly. Their robust design ensures consistent performance even in demanding environments. They come equipped with automatic ignition systems that enhance safety and operational ease. Our Flame Photometer are commonly applied in laboratories for analyzing concentration of elements in biological and chemical samples.
Flame Photometer LMFM-A100 Catalog
| Elements Detected | K, Na |
| Sample Uptake | < 6mL/ min |
| Response Time | < 8 s |
| Dimension | 400 × 250 × 500 mm |
| Repeatability | < 3% coefficient of variation for 7 consecutive samples |
Flame Photometer LMFM-A101 Catalog
| Test Element | K, Na, Li |
| Channel Quantity | 3 |
| Test Range | K: 0.15 to 100 ppm, Na: 0.18 to 100 ppm, Li: 0.1 to 30 ppm |
| Limit Of Detection | K: less than or equal to 0.158 ppm, Na: less than or equal to 0.184 ppm, Li: less than or equal to 0.1035 ppm |
| Linear Error | K: less than or equal to 0.195 ppm, Na: less than or equal to 0.69 ppm, Li: less than or equal to 0.1449 ppm |
Flame Photometer LMFM-A102 Catalog
| Test Element | K, Na, Ca |
| Channel Quantity | 3 |
| Test Range | K: 0.15 to 100 ppm, Na: 0.18 to 100 ppm, Ca: 0.1 to 1000 ppm |
| Limit Of Detection | K: less than or equal to 0.158 ppm, Na: less than or equal to 0.184 ppm, Ca: less than or equal to 2 ppm |
| Linear Error | K: less than or equal to 0.195 ppm, Na: less than or equal to 0.69 ppm, Ca: less than or equal to 3 ppm |
Flame Photometer LMFM-A103 Catalog
| Test Element | K, Na, Ca, Li |
| Channel Quantity | 4 |
| Test Range | K: 0.15 to 100 ppm, Na: 0.18 to 100 ppm, Li: 0.1 to 30 ppm, Ca: 0.1 to 1000 ppm |
| Limit Of Detection | K: less than or equal to 0.158 ppm, Na: less than or equal to 0.184 ppm, Li: less than or equal to 0.1032 ppm, Ca: less than or equal to 2 ppm |
| Linear Error | K: less than or equal to 0.195 ppm, Na: less than or equal to 0.69 ppm, Li: less than or equal to 0.1449 ppm, Ca: less than or equal to 3 ppm |
Flame Photometer LMFM-A104 Catalog
| Test Element | K, Na, Ca, Li, Ba |
| Channel Quantity | 5 |
| Test Range | K: 0.15 to 100 ppm, Na: 0.18 to 100 ppm, Li: 0.1 to 30 ppm, Ca: 0.1 to 1000 ppm, Ba: 0.1 to 300 ppm |
| Limit Of Detection | K: less than or equal to 0.158 ppm, Na: less than or equal to 0.184 ppm, Li: less than or equal to 0.1032 ppm, Ca: less than or equal to 2 ppm, Ba: less than or equal to 6.028 |
| Linear Error | K: less than or equal to 0.195 ppm, Na: less than or equal to 0.69 ppm, Li: less than or equal to 0.1449 ppm, Ba: less than or equal to 9.402, Ca: less than or equal to 3 ppm |
Flame Photometer LMFM-B100 Catalog
| Test Element | K, Na, Li, Ca, Ba |
| Channel Quantity | 5 |
| Reading Range | Concentration: 0.000 to 999.9, Energy 0 to 65535 |
| Test Range | K: 0 to 100 ppm, Na: 0 to 160 ppm, Li: 0 to 100 ppm, Ca: 0 to 1000 ppm, Ba: 0 to 3000ppm |
| Limit Of Detection | K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Li: less than 0.015mmol/L, Ca: less than 0.050mmol/L, Ba: less than 0.044mmol/L |
Flame Photometer LMFM-B101 Catalog
| Test Element | K, Na, Li, Ca |
| Channel Quantity | 4 |
| Reading Range | Concentration: 0.000 to 999.9, Energy 0 to 65535 |
| Test Range | K: 0 to 100 ppm, Na: 0 to 160 ppm, Li: 0 to 100 ppm, Ca: 0 to 1000 ppm |
| Limit Of Detection | K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Li: less than 0.015mmol/L, Ca: less than 0.050mmol/L |
Flame Photometer LMFM-B102 Catalog
| Test Element | K, Na, Ba |
| Channel Quantity | 3 |
| Reading Range | Concentration: 0.000 to 999.9, Energy 0 to 65535 |
| Test Range | K: 0 to 100 ppm, Na: 0 to 160 ppm, Ba: 0 to 3000 ppm |
| Limit Of Detection | K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Ba: less than 0.044mmol/L |
Flame Photometer LMFM-B103 Catalog
| Test Element | K, Na, Ca |
| Channel Quantity | 3 |
| Reading Range | Concentration: 0.000 to 999.9, Energy 0 to 65535 |
| Test Range | K: 0 to 100 ppm, Na: 0 to 160 ppm, Ca: 0 to 1000 ppm |
| Limit Of Detection | K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Ca: less than 0.050mmol/L |
Flame Photometer LMFM-B104 Catalog
| Test Element | K, Na, Li |
| Channel Quantity | 3 |
| Reading Range | Concentration: 0.000 to 999.9, Energy 0 to 65535 |
| Test Range | K: 0 to 100 ppm, Na: 0 to 160 ppm, Li: 0 to 100 ppm |
| Limit Of Detection | K: less than 0.004mmol/L, Na: less than 0.008mmol/L, Li: less than 0.015mmol/L |