Differential Scanning Calorimeter Catalogs

Labmate Differential Scanning Calorimeter has temperature range of -150°C to 800°C. They perform thermal transitions through constant heat rate monitoring during heating or cooling processes. They offer user-friendly interface for seamless operation with real-time data display. They integrate high sensitivity and stability for analyzing small sample sizes Our Differential Scanning Calorimeter are ideal for analyzing thermal properties of materials such as polymers or pharmaceuticals to determine their melting point and crystallization.

Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-A100 Catalog Differential Scanning Calorimeter LMDSC-A100 Catalog
DSC Range 0 to ± 600mW
Temperature Range Room Temperature to 600°C
Heating Rate 0.1 to 100℃/min
Cooling Method Air Cooled
Scanning Method Heating
Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-A102 Catalog Differential Scanning Calorimeter LMDSC-A102 Catalog
DSC Range 0 to ± 600mW
Temperature Range -100°C to 800°C
Heating Rate 0.1 to 80℃/min
Cooling Method Liquid Nitrogen Cooled
Scanning Method Heating
Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-A103 Catalog Differential Scanning Calorimeter LMDSC-A103 Catalog
Temperature Range RT to 550 ° C(Air-cooled)
Temperature Resolution 0.001 °C
Temperature Fluctuation ± 0.001 °C
Temperature Repeatability ± 0.1 °C
Heating Rate 0.1 ~ 80 °C/ min
Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-A104 Catalog Differential Scanning Calorimeter LMDSC-A104 Catalog
DSC Range 0 to ± 600mW
Temperature Range -170°C to 600°C
Heating Rate 0.1 to 100℃/min
Cooling Rate 0.1 to 40℃/min
Cooling Method Liquid Nitrogen Cooled
Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-A105 Catalog Differential Scanning Calorimeter LMDSC-A105 Catalog
DSC Range 0 to ± 800mW
Temperature Range -40°C to 600°C
Heating Rate 0.1 to 100℃/min
Cooling Rate 0.1 to 40℃/min
Cooling Method Mechanical Cooled
Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-A101 Catalog Differential Scanning Calorimeter LMDSC-A101 Catalog
DSC Range 0 to ± 600mW
Temperature Range Room Temperature to 600°C
Heating Rate 0.1 to 100℃/min
Cooling Method Air Cooled
Scanning Method Heating and Cooling
Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-B100 Catalog Differential Scanning Calorimeter LMDSC-B100 Catalog
DSC Range 0 to ±2000 mW
Temperature Range Room temperature to 600 ℃
Sampling Rate 1 to 10 Hz (Programmable)
Toggle Rate 16.6 Hz
Heating Rate 0.1 to 100 ℃/min
Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-B101 Catalog Differential Scanning Calorimeter LMDSC-B101 Catalog
DSC Range 0 to ±1000 mW
Temperature Range -40 to 600 ℃
Sampling Rate 1 to 10 Hz (Programmable)
Toggle Rate 16.6 Hz
Heating Rate 0.1 to 100 ℃/min
Labmate Scientific LLC Differential Scanning Calorimeter LMDSC-B102 Catalog Differential Scanning Calorimeter LMDSC-B102 Catalog
DSC Range 0 to ±2000 mW
Temperature Range -170 to 600 ℃
Sampling Rate 1 to 10 Hz (Programmable)
Toggle Rate 16.6 Hz
Heating Rate 0.1 to 100 ℃/min