Get Quote
Contact us now to receive a detailed quotation.
Labmate Differential Scanning Calorimeter has temperature range of -150°C to 800°C. They perform thermal transitions through constant heat rate monitoring during heating or cooling processes. They offer user-friendly interface for seamless operation with real-time data display. They integrate high sensitivity and stability for analyzing small sample sizes Our Differential Scanning Calorimeter are ideal for analyzing thermal properties of materials such as polymers or pharmaceuticals to determine their melting point and crystallization.
Differential Scanning Calorimeter LMDSC-A100 Catalog
| DSC Range | 0 to ± 600mW |
| Temperature Range | Room Temperature to 600°C |
| Heating Rate | 0.1 to 100℃/min |
| Cooling Method | Air Cooled |
| Scanning Method | Heating |
Differential Scanning Calorimeter LMDSC-A102 Catalog
| DSC Range | 0 to ± 600mW |
| Temperature Range | -100°C to 800°C |
| Heating Rate | 0.1 to 80℃/min |
| Cooling Method | Liquid Nitrogen Cooled |
| Scanning Method | Heating |
Differential Scanning Calorimeter LMDSC-A103 Catalog
| Temperature Range | RT to 550 ° C(Air-cooled) |
| Temperature Resolution | 0.001 °C |
| Temperature Fluctuation | ± 0.001 °C |
| Temperature Repeatability | ± 0.1 °C |
| Heating Rate | 0.1 ~ 80 °C/ min |
Differential Scanning Calorimeter LMDSC-A104 Catalog
| DSC Range | 0 to ± 600mW |
| Temperature Range | -170°C to 600°C |
| Heating Rate | 0.1 to 100℃/min |
| Cooling Rate | 0.1 to 40℃/min |
| Cooling Method | Liquid Nitrogen Cooled |
Differential Scanning Calorimeter LMDSC-A105 Catalog
| DSC Range | 0 to ± 800mW |
| Temperature Range | -40°C to 600°C |
| Heating Rate | 0.1 to 100℃/min |
| Cooling Rate | 0.1 to 40℃/min |
| Cooling Method | Mechanical Cooled |
Differential Scanning Calorimeter LMDSC-A101 Catalog
| DSC Range | 0 to ± 600mW |
| Temperature Range | Room Temperature to 600°C |
| Heating Rate | 0.1 to 100℃/min |
| Cooling Method | Air Cooled |
| Scanning Method | Heating and Cooling |
Differential Scanning Calorimeter LMDSC-B100 Catalog
| DSC Range | 0 to ±2000 mW |
| Temperature Range | Room temperature to 600 ℃ |
| Sampling Rate | 1 to 10 Hz (Programmable) |
| Toggle Rate | 16.6 Hz |
| Heating Rate | 0.1 to 100 ℃/min |
Differential Scanning Calorimeter LMDSC-B101 Catalog
| DSC Range | 0 to ±1000 mW |
| Temperature Range | -40 to 600 ℃ |
| Sampling Rate | 1 to 10 Hz (Programmable) |
| Toggle Rate | 16.6 Hz |
| Heating Rate | 0.1 to 100 ℃/min |
Differential Scanning Calorimeter LMDSC-B102 Catalog
| DSC Range | 0 to ±2000 mW |
| Temperature Range | -170 to 600 ℃ |
| Sampling Rate | 1 to 10 Hz (Programmable) |
| Toggle Rate | 16.6 Hz |
| Heating Rate | 0.1 to 100 ℃/min |