Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Automatic Hematology Analyzer LMHA-A1002

Automatic Hematology Analyzer LMHA-A1002 has an advanced tri-angle laser scattering technology to obtain information on the size and internal composition of WBC and classify them. Built-in reagent room for two lyses, saves more space for operation. It has the capability to measure 28 types of parameters as per the user’s requirement. With 60 samples/ hour throughput and manual or auto calibration, the unit can be used for 19 different species.

Catalog Send Mail Whatsapp

Specifications

Parameters 28 Parameters: WBC, LYM%, MON%, NEU%, BAS%, EOS%, LYM#, MON#, NEU#, EOS#, BAS#,RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV,RDW-SD, PLT, MPV, PDW-CV, PDW-SD, PCT,P-LCR, P-LCC, NLR, PLR
Performance Precision 60 samples per hour
Sample Volume 60,000 sample results withscattergrams and histograms
Efficiency 3 Reagent (2 Lyse + 1 Diluent)1 Probe cleanser for maintenance
Power Supply 4 USB ports, 1 LAN port, HL7 protocol, support LIS
Case Storage 100 – 240 V, 50/60 Hz
Display 10.4-inch colour touch screen
Dimensions (L × D × H) 430 × 350 × 435 mm
Weight 28 Kg

Pricing

Product Price Unit Action
Automatic Hematology Analyzer LMHA-A1002 $ 14000 Pack of 1

Features

Compact yet powerful, 28 parameters detecting analysis
Real 5-part Hemanalysis with direst counting and differentiation for basophil
Manual and auto calibration
60,000 sample results with scattergrams and histograms
All-in-one model consisting of a printer, barcode scanner and card reader

Applications

Hematology Analyzers are used to run tests on blood samples. They are used in the medical field to do white blood cell counts, complete blood counts, reticulocyte analysis, and coagulation tests.

Similar Products

Automatic Hematology Analyzer LMAHA-A100

  • Measuring Principle: Electro-impedance, photometric analysis
  • Throughput: 60 tests/hr
  • Assay Items: 22 parameters, 3 parts differential of WBC
  • Parameter: WBC, LY, LY%, MO, MO%, GR, GR%, RBC, HGB, HCT, MCV, RDW-SD, RDW-SD, RDW-CV, MCH, MCHC, PLT, MPV, PCT, PDW, WBC histograms, RBC histograms, PLT histograms
  • Sample Volume: 13µl (whole blood), 20µl (prediluted blood)

$ 4462.5 / Each of 1

Hematology Analyzer LMHA-A901

  • Principles: Impedance method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Tri-angle laser scattermethod for WBC 5-part differential analysis and WBC counting
  • Parameters: 27 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym# ,Mon#, Neu#, Eos# , Bas#, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-CV, RDW-SD,PLI, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY# 3 histograms for WBC, RBC and PLT 3 DIFF scatter grams and 1 BASO scatter gram
  • Reagent: DIL-C Diluent, LYC-1 LYSE, LYC-2 LYSE, CLE-P
  • Linearity Range: WBC (0.00-300.00)X 10%/L RBC (0.00-8.50)X1012/L HGB (0-250)G/L PLT (0-3000)X 10%/L HCT 0.0-67.0%
  • Repeatability: WBC≤2.0% RBC≤1.5% HGB≤1.5% PLT≤4.0% MCV≤1.0%

$ 11250 / Pack of 1

Auto Hematology Analyzer LMHA-A902

  • Throughput: 60 Samples/Hour
  • Sample Volume: 10 μL
  • Prediluted Mode: 20 μL
  • Storage: Up to 60000 results
  • Reagents: 3 For Test

$ 16825 / Pack of 1

Automatic Hematology Analyzer LMHA-A1001
  • Sample Volume: Whole blood: 15µl, Diluted blood: 20µl
  • Throughput: 60 T/H
  • Sample Mode: Whole Blood (Venous/Capillary), Pre-dilution
  • Parameters: 25 Parameters: WBC, LYM%, LYM#, NEU%, NEU#, MON%, MON#, EOS%, EOS#, BAS%, BAS#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, P-LCC
  • Accuracy: WBC: Less than or equal to 4.0, RBC: Less than or equal to 2.0, HGB: Less than or equal to 2.0, PLT (103/ µl): Less than or equal to 4.0, MCV: Less than or equal to 3.0

$ 7940 / Each of 1

Automatic Hematology Analyzer LMAHA-A101
  • Throughput: 60 samples/hr
  • Sample Volume: ≤20 µl
  • Parameter: Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC.RDW-SD, RDW-CV, PLT, MPV, PCT, PDWP-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#
  • Study parameter: ALY%, ALY#, LIC%, LIC#
  • Temperature: 10 to 30℃

$ 6562.5 / Pack of 1

Frequently Asked Questions

1 What is an Automatic Hematology Analyzer?

An Automatic Hematology Analyzer is an apparatus designed to perform Complete Blood Counts (CBCs) and other blood-related tests quickly and accurately by automating the analysis of blood samples.

2 How does Automatic Hematology Analyzer work?

It works by drawing blood into the system and using technologies such as flow cytometry, electrical impedance, and optical detection to count and differentiate blood cells.

3 What parameters can Automatic Hematology Analyzer measure?

It measures parameters such as Red Blood Cell (RBC) count, White Blood Cell (WBC) count, hemoglobin, hematocrit, platelet count, and various WBC differentials.

4 Why is Automatic Hematology Analyzer important in clinical diagnostics?

It is essential in clinical diagnostics because it provides fast, reliable, and repeatable results that help in the diagnosis and monitoring of various health conditions like anemia, infections, and blood disorders.

5 Can Automatic Hematology Analyzer detect abnormal cells?

It can flag potential abnormal cells or unusual results, prompting further investigation through peripheral smear review or additional testing.

6 What kind of maintenance does Automatic Hematology Analyzer require?

Routine maintenance includes daily cleaning, reagent replacement, checking for clogs, regular calibration and quality control checks.

7 How is Automatic Hematology Analyzer used in emergency situations?

It provides rapid CBC results that help assess critical conditions such as infections, anemia, or blood loss, enabling quick clinical decisions.

8 Can Automatic Hematology Analyzer be used for pre-surgical evaluations?

It is commonly used in preoperative assessments to ensure normal blood counts, identify anemia or clotting issues, and reduce surgical risks.

9 How does Automatic Hematology Analyzer support public health screenings?

It can be used for mass screenings to detect conditions such as anemia, infections, or nutritional deficiencies in populations.

10 How does Automatic Hematology Analyzer support infection control in hospitals?

It helps track changes in WBC counts and inflammatory markers, allowing clinicians to monitor infection progression or response to antibiotics.