Automatic Hematology Analyzer LMHA-A1001

Automatic Hematology Analyzer LMHA-A1001 features minimal sample requirement of 15 µL per test. It has multi-segment counting method with strong anti-interference capability ensuring dependable results. Equipped with automatic maintenance and one-click troubleshooting, it enhances smooth functioning. Incorporates digital filtering and coincidence correction for reliable counting during high throughput analysis. Our Hematology Analyzer is ideal for various blood analysis.

Catalog Send Mail Whatsapp

Specifications

Sample Volume Whole blood: 15µl, Diluted blood: 20µl
Throughput 60 T/H
Sample Mode Whole Blood (Venous/Capillary), Pre-dilution
Parameters 25 Parameters: WBC, LYM%, LYM#, NEU%, NEU#, MON%, MON#, EOS%, EOS#, BAS%, BAS#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, P-LCC
Accuracy WBC: Less than or equal to 4.0, RBC: Less than or equal to 2.0, HGB: Less than or equal to 2.0, PLT (103/ µl): Less than or equal to 4.0, MCV: Less than or equal to 3.0
QC Methods L-J QC, X-B QC
Data Storage 10,000 samples
Display 10.4-inch Resistive Screen
Working Temperature 18 to 30°C
Working Humidity Less than or equal to 80% Relative Humidity
Working Pressure 75 to 106 kPa
Power Supply 100 to 240 V, 50/60 Hz
Dimension 328×471×446 mm
Weight 21 kg

Pricing

Product Price Unit Action
Automatic Hematology Analyzer LMHA-A1001 $ 7940 Each of 1

Features

Anti-clogging functions

Columnar Pt electrode

Integrated printer

Glove operation

Laser irradiation

Curve fitting

Applications

Automatic Hematology Analyzer LMHA-A1001 is applied for blood analysis, supporting white cell counts, complete counts, reticulocyte study, and coagulation diagnostic testing in clinical laboratories.

Similar Products

Automatic Hematology Analyzer LMAHA-A101

  • Throughput: 60 samples/hr
  • Sample Volume: ≤20 µl
  • Parameter: Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC.RDW-SD, RDW-CV, PLT, MPV, PCT, PDWP-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#
  • Study parameter: ALY%, ALY#, LIC%, LIC#
  • Temperature: 10 to 30℃

$ 6562.5 / Pack of 1

Automatic Hematology Analyzer LMHA-A1002

  • Parameters: 28 Parameters: WBC, LYM%, MON%, NEU%, BAS%, EOS%, LYM#, MON#, NEU#, EOS#, BAS#,RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV,RDW-SD, PLT, MPV, PDW-CV, PDW-SD, PCT,P-LCR, P-LCC, NLR, PLR
  • Performance Precision: 60 samples per hour
  • Sample Volume: 60,000 sample results withscattergrams and histograms
  • Efficiency: 3 Reagent (2 Lyse + 1 Diluent)1 Probe cleanser for maintenance
  • Power Supply: 4 USB ports, 1 LAN port, HL7 protocol, support LIS

$ 14000 / Pack of 1

Hematology Analyzer LMHA-A901

  • Principles: Impedance method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Tri-angle laser scattermethod for WBC 5-part differential analysis and WBC counting
  • Parameters: 27 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym# ,Mon#, Neu#, Eos# , Bas#, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-CV, RDW-SD,PLI, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY# 3 histograms for WBC, RBC and PLT 3 DIFF scatter grams and 1 BASO scatter gram
  • Reagent: DIL-C Diluent, LYC-1 LYSE, LYC-2 LYSE, CLE-P
  • Linearity Range: WBC (0.00-300.00)X 10%/L RBC (0.00-8.50)X1012/L HGB (0-250)G/L PLT (0-3000)X 10%/L HCT 0.0-67.0%
  • Repeatability: WBC≤2.0% RBC≤1.5% HGB≤1.5% PLT≤4.0% MCV≤1.0%

$ 11250 / Pack of 1

Automatic Hematology Analyzer LMAHA-A100
  • Measuring Principle: Electro-impedance, photometric analysis
  • Throughput: 60 tests/hr
  • Assay Items: 22 parameters, 3 parts differential of WBC
  • Parameter: WBC, LY, LY%, MO, MO%, GR, GR%, RBC, HGB, HCT, MCV, RDW-SD, RDW-SD, RDW-CV, MCH, MCHC, PLT, MPV, PCT, PDW, WBC histograms, RBC histograms, PLT histograms
  • Sample Volume: 13µl (whole blood), 20µl (prediluted blood)

$ 4462.5 / Each of 1

Auto Hematology Analyzer LMHA-A902
  • Throughput: 60 Samples/Hour
  • Sample Volume: 10 μL
  • Prediluted Mode: 20 μL
  • Storage: Up to 60000 results
  • Reagents: 3 For Test

$ 16825 / Pack of 1

Frequently Asked Questions

1 What is an Automatic Hematology Analyzer?

An Automatic Hematology Analyzer is an apparatus designed to perform Complete Blood Counts (CBCs) and other blood-related tests quickly and accurately by automating the analysis of blood samples.

2 How does Automatic Hematology Analyzer work?

It works by drawing blood into the system and using technologies such as flow cytometry, electrical impedance, and optical detection to count and differentiate blood cells.

3 What parameters can Automatic Hematology Analyzer measure?

It measures parameters such as Red Blood Cell (RBC) count, White Blood Cell (WBC) count, hemoglobin, hematocrit, platelet count, and various WBC differentials.

4 Why is Automatic Hematology Analyzer important in clinical diagnostics?

It is essential in clinical diagnostics because it provides fast, reliable, and repeatable results that help in the diagnosis and monitoring of various health conditions like anemia, infections, and blood disorders.

5 Can Automatic Hematology Analyzer detect abnormal cells?

It can flag potential abnormal cells or unusual results, prompting further investigation through peripheral smear review or additional testing.

6 What kind of maintenance does Automatic Hematology Analyzer require?

Routine maintenance includes daily cleaning, reagent replacement, checking for clogs, regular calibration and quality control checks.

7 How is Automatic Hematology Analyzer used in emergency situations?

It provides rapid CBC results that help assess critical conditions such as infections, anemia, or blood loss, enabling quick clinical decisions.

8 Can Automatic Hematology Analyzer be used for pre-surgical evaluations?

It is commonly used in preoperative assessments to ensure normal blood counts, identify anemia or clotting issues, and reduce surgical risks.

9 How does Automatic Hematology Analyzer support public health screenings?

It can be used for mass screenings to detect conditions such as anemia, infections, or nutritional deficiencies in populations.

10 How does Automatic Hematology Analyzer support infection control in hospitals?

It helps track changes in WBC counts and inflammatory markers, allowing clinicians to monitor infection progression or response to antibiotics.