Vertical Autoclave LMVT-A202

Vertical Autoclave LMVT-A202 is a compact and spacious-free autoclave that offers outstanding performance during sterilization of laboratory applications. It features a capacity of 75 L that stimulates a temperature range between 105 °C to 134 °C. All parameters displayed on the LED screen allow intuitive operation for quick recognition. Improved with handle door lock system to ensure sample safety with advanced protocol.

Catalog Send Mail Whatsapp

Specifications

Capacity 75 L
Temperature Range 134 °C
Maximum Pressure 0.23 MPa
Time Range 0 - 99 min or 0 - 99 hours 59 min
Chamber Size φ 400 × 600 mm
Working Pressure 0.22 MPa
Sterilizing Temperature 105 °C - 134 °C
Power 4.5 kW
Voltage 220 V
Heat Average ≤ ± 1 °C
Dimension 560 × 560 × 1120 mm
Net Weight 80 Kg
Gross Weight 100 Kg

Pricing

Product Price Unit Action
Vertical Autoclave LMVT-A202 $ 2825 Pack of 1

Features

User-friendly easy to view LED display offers clear observation of working temperature
Structured with robust and spark-free stainless steel ensures long-term usability
Equipped with a corrosion-resistant chamber enables tool-free cleaning
Effortless handling with minimal maintenance 
Easily adjustable with high reliability and safety
Employed with alarm alert indication during automatic shut-off
Configured with a safety control system to prevent protection against overloading and temperature deviation
Improved with auto discharge of cool air and steam to ensure worry-free operation

Applications

It is extensively used to sterilize surgical equipment, laboratory instruments, pharmaceutical items, and other materials.

Similar Products

Vertical Autoclave LMVT-A100

  • Capacity: 35 L
  • Temperature Range: 134 °C
  • Pressure: 0.22 MPa
  • Time Range: 0 - 60 min
  • Chamber Size: φ 318 × 450 mm

$ 2175 / Pack of 1

Vertical Autoclave LMVT-A501

  • Capacity: 50 L
  • Working Pressure: 0.142 MPa
  • Sterilizing Temperature: 50 - 126 °C
  • Time Range: 0 - 99 h
  • Material: Stainless steel

$ 2925 / Pack of 1

Vertical Autoclave LMVT-A201

  • Capacity: 50 L
  • Temperature Range: 134 °C
  • Maximum Pressure: 0.23 MPa
  • Time Range: 0 - 99 min or 0 - 99 hours 59 min
  • Chamber Size: φ 340 × 550 mm

$ 2525 / Pack of 1

Vertical Autoclave LMVT-A203
  • Capacity: 100 L
  • Temperature Range: 134 °C
  • Maximum Pressure: 0.23 MPa
  • Time Range: 0 - 99 min or 0 - 99 hours 59 min
  • Chamber Size: φ 440 × 650 mm

$ 3437.5 / Pack of 1

Vertical Autoclave LMVT-A400
  • Capacity: 30 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 hr
  • Chamber Size: 370 × 320 mm
  • Sterilizing Temperature: 50 - 134 °C

$ 3075 / Pack of 1

Vertical Autoclave LMVT-A408

  • Capacity: 75 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 hr
  • Chamber Size: 370 × 690 mm
  • Sterilizing Temperature: 50 - 134 °C

$ 3450 / Pack of 1

Vertical Autoclave LMVT-A403

  • Capacity: 30 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 hr
  • Chamber Size: 370 × 320 mm
  • Sterilizing Temperature: 50 - 134 °C

$ 3237.5 / Pack of 1

Vertical Autoclave LMVT-A604

  • Capacity: 60 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 h
  • Sterilizing Temperature: 50 - 134 °C
  • Material: Stainless steel

$ 3312.5 / Pack of 1

Vertical Autoclave LMVT-A505
  • Capacity: 200 L
  • Working Pressure: 0.217 MPa
  • Sterilizing Temperature: 50 - 134 °C
  • Time Range: 0 - 99 h
  • Material: Stainless steel

$ 4987.5 / Pack of 1

Vertical Autoclave LMVT-A404
  • Capacity: 50 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 hr
  • Chamber Size: 370 × 500 mm
  • Sterilizing Temperature: 50 - 134 °C

$ 3450 / Pack of 1

Vertical Autoclave LMVT-A704

  • Volume: 75 L
  • Working Temperature: 135°C
  • Maximum Temperature: 139°C
  • Working Pressure: 0.22 MPa
  • Maximum Pressure: 0.25 MPa

$ 4500 / Each of 1

Vertical Autoclave LMVT-A607

  • Capacity: 60 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 h
  • Sterilizing Temperature: 50 - 134 °C
  • Material: Stainless steel

$ 3975 / Pack of 1

Vertical Autoclave LMVT-A406

  • Capacity: 30 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 hr
  • Chamber Size: 370 × 320 mm
  • Sterilizing Temperature: 50 - 134 °C

$ 3400 / Pack of 1

Vertical Autoclave LMVT-A606
  • Capacity: 40 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 h
  • Sterilizing Temperature: 50 - 134 °C
  • Material: Stainless steel

$ 3462.5 / Pack of 1

Vertical Autoclave LMVT-A602
  • Capacity: 80 L
  • Working Pressure: 0.217 MPa
  • Time Range: 0 - 99 h
  • Sterilizing Temperature: 50 - 134 °C
  • Material: Stainless steel

$ 3150 / Pack of 1

Frequently Asked Questions

1 What is a Vertical Autoclave LMVT-A202?

A Vertical Autoclave LMVT-A202 is a top-loading steam sterilizer designed for efficient and safe sterilization.

2 How does Vertical Autoclave LMVT-A202 work?

Vertical Autoclave LMVT-A202 works on the principle of moist heat sterilization using pressurized steam.

3 What materials can be sterilized using the Vertical Autoclave LMVT-A202?

Vertical Autoclave LMVT-A202 can sterilize instruments, glassware, liquids, culture media, and other heat-resistant laboratory items.

4 How does Vertical Autoclave LMVT-A202 handle biohazardous waste?

Vertical Autoclave LMVT-A202 is used for decontaminating biohazardous waste before disposal by effectively neutralizing pathogens.

5 Can Vertical Autoclave LMVT-A202 be used in dental clinics?

Vertical Autoclave LMVT-A202 is suitable for use in dental clinics to sterilize tools like mirrors, forceps, and other dental instruments.

6 Can Vertical Autoclave LMVT-A202 be used in food testing laboratories?

Vertical Autoclave LMVT-A202 is used in food testing laboratories to sterilize sample containers and microbiological media.

7 Is Vertical Autoclave LMVT-A202 suitable for environmental testing laboratories?

Vertical Autoclave LMVT-A202 is well-suited for environmental testing laboratories that require sterilization of sampling tools and containers.

8 Is Vertical Autoclave LMVT-A202 used in genetic research laboratories?

Vertical Autoclave LMVT-A202 is used in genetic research laboratories to sterilize equipment and media.

9 Can Vertical Autoclave LMVT-A202 be used for sterilizing water samples in water treatment laboratories?

Vertical Autoclave LMVT-A202 is used to sterilize water samples before microbiological testing in water treatment laboratories.

10 Can Vertical Autoclave LMVT-A202 sterilize equipment used in stem cell culture?

Vertical Autoclave LMVT-A202 is used to sterilize equipment and tools used in stem cell culture laboratories.

11 What is a Vertical Autoclave?

A Vertical Autoclave is a cylindrical apparatus designed to decontaminate equipment and materials through high-pressure saturated steam.

12 How does a Vertical Autoclave work?

It sterilizes items using high-pressure steam inside an upright cylindrical chamber.

13 What can be sterilized in Vertical Autoclave?

It can sterilize glassware, surgical instruments, culture media and heat-resistant plastics.

14 What is the difference between Vertical and Horizontal Autoclave?

Vertical Autoclave is compact and loaded from the top, whereas Horizontal Autoclave is larger and loaded from the front for higher capacity.

15 What safety features are included in Vertical Autoclave?

Safety features include pressure release valves, temperature sensors and automatic shut-off systems.

16 Can Vertical Autoclave be used for medical waste disposal?

It is commonly used for sterilizing biohazardous waste before disposal.

17 Can Vertical Autoclave be used for pharmaceutical applications?

It is widely used for sterilizing equipment and media in pharmaceutical labs.

18 Can metal instruments be sterilized in Vertical Autoclave?

Metal instruments like surgical tools are commonly sterilized in Vertical Autoclave.

19 Can Vertical Autoclave be used for food sterilization?

It is used in food processing, for items requiring heat sterilization such as canned goods.

20 How does Vertical Autoclave prevent contamination during the cycle?

It maintains a sealed environment with pressure and temperature control, ensuring that no contaminants enter during the sterilization process.