Low-Temperature Plasma Sterilizer LMLA-A103

Low-Temperature Plasma Sterilizer LMLA-A103 improved with sterilization method for heat-sensitive medical instruments, providing efficient and safe sterilization with minimal damage. Upgraded with infrared sensor detects the presence of potentially harmful microorganisms or contaminants enhance air hygiene. Designed with a user-friendly touch control panel for convenient manual operation.

Catalog Send Mail Whatsapp

Specifications

Applicable Room < 100 m³
Type Ceiling Mounted
Circulating Air > 800 m³
Working Temperature -10 °C to 40 °C
Working Pressure 86 to 106 kPa
Working Humidity < 90 %
O3 Residue < 0.003 mg /m³
Noise < 55 dB (A)
Power 80 W
Voltage AC 110 / 220 V; 50 / 60 Hz
Dimension 680 × 680 × 300 mm
Weight 38 Kg

Features

Adjustable air flow speed
Multi - Point particle monitoring
Infrared sensor for automatic sterilization
Touch control panel with remote control Accurate time display
Multiple sensor for inspect air quality, temperature and Humidity

Applications

Low-Temperature Plasma Sterilizer is widely used in medical settings to sterilize heat-sensitive medical equipment, including surgical instruments, endoscopes, and other vital tools.

Similar Products

Low-Temperature Plasma Sterilizer LMLA-C101

  • Capacity: 225 L
  • Sterilization Method: Ethylene Oxide Sterilization
  • High Temperature: 55 °C
  • Low Temperature: 37 °C
  • Power: 4.5 kW

Low-Temperature Plasma Sterilizer LMLA-B102

  • Capacity: 225 L
  • Sterilization Method: Hydrogen Peroxide Gas Sterilization
  • Working Temperature: 50 ± 5 °C
  • Power: 4.7 kW
  • Voltage: 380 V; 50 Hz

Low-Temperature Plasma Sterilizer LMLA-A102

  • Applicable Room: < 100 m³
  • Type: Wall Mounted
  • Circulating Air: > 800 m³
  • Working Temperature: -10 °C to 40 °C
  • Working Pressure: 86 to 106 kPa
Low-Temperature Plasma Sterilizer LMLA-C100
  • Capacity: 135 L
  • Sterilization Method: Ethylene Oxide Sterilization
  • High Temperature: 55 °C
  • Low Temperature: 37 °C
  • Power: 3.5 kW
Low-Temperature Plasma Sterilizer LMLA-A100
  • Applicable Room: < 100 m³
  • Type: Free Standing
  • Circulating Air: > 800 m³
  • Working Temperature: -10 °C to 40 °C
  • Working Pressure: 86 to 106 kPa

Low-Temperature Plasma Sterilizer LMLA-A101

  • Applicable Room: < 100 m³
  • Type: Mobile
  • Circulating Air: > 800 m³
  • Working Temperature: -10 °C to 40 °C
  • Working Pressure: 86 to 106 kPa

Low-Temperature Plasma Sterilizer LMLA-B101

  • Capacity: 135 L
  • Sterilization Method: Hydrogen Peroxide Gas Sterilization
  • Working Temperature: 50 ± 5 °C
  • Power: 3.8 kW
  • Voltage: 380 V; 50 Hz

Low-Temperature Plasma Sterilizer LMLA-B100

  • Capacity: 60 L
  • Sterilization Method: Hydrogen Peroxide Gas Sterilization
  • Working Temperature: 45 to 55°C
  • Sterilization Time: Short cycle 35 minutes Long cycle 55 minutes
  • Record: Built-in thermal printer, real-time print-out data USB port available for historical data download
Low-Temperature Plasma Sterilizer LMLA-B103
  • Capacity: 120L
  • Sterilization Method: Hydrogen Peroxide Gas Sterilization
  • Shelves: Long Shelves
  • Working Temperature Range: 45 to 55℃
  • Power Consumption: 4000 W
Low-Temperature Plasma Sterilizer LMLA-B104
  • Capacity: 200L
  • Sterilization Method: Hydrogen Peroxide Gas Sterilization
  • Shelves: Long Shelves
  • Working Temperature Range: 45 to 55℃
  • Power Consumption: 4200 W