Get Quote

Contact us now to receive a detailed quotation.

Flow Cytometer LMFC-A102

Flow Cytometer LMFC-A102 offers high performance with flexible configuration, supporting up to 3 lasers and 15 fluorescence channels. It can measure up to 18 different parameters at once, which ensures in-depth profiling of complex samples. Equipped with a precision pump system for consistent, volume based absolute cell counting. Engineered for high efficiency spectral separation with minimal filters and precise detection sensitivity. Our Flow Cytometer supports tube rotaries and microplates with integrated mixing function.

Catalog Send Mail Whatsapp

Specifications

Laser configuration Supports up to three lasers: 405 nm (100 mW), 488 nm (60 mW), and 638 nm (80 mW)
Detector APD Type
Fluorescence detection limit FITC < 50MESF; PE < 30MESF; APC < 30MESF
Fluorescence linearity ≥ 0.99
Instrument resolution < 2%
Forward scattered light resolution < 0.45 μm
Detection particle range 0.2 – 50 μm
Carry over rate < 0.1%
Detection speed > 50000 events/s
Absolute count Compatible with volumetric and microsphere absolute counting
Signal range Maximum 10⁷
Preset Injection speed Low: 15 μL/min; Medium: 30 μL/min;
Adjustable Injection Speed 15–120 μL/min
Threshold setting Supports dual thresholds to minimize cell debris
Fluorescence compensation Online, offline, and visual compensation modes
Project template Support project template, One-click recall, and fluorescence settings
Instrument quality control Automatic daily QC inspection, tracking, and recording through Levey Jennings
Manual Sample Injection Mode Single tube manual sampling
Automated Sample Injection Mode 40 tubes auto sampler
Microplate Compatibility 96-hole plates
Software English interface for real-time data capture and analysis.
File format Supports FCS 3.1, FCS 3.0, and FCS 2.0 file formats
Maintenance method shutdown cleaning, cleaning between experiments, bubble exhaust, and monthly deep cleaning via automatic procedures.
Size (L×W×H) 760mm × 450mm × 470mm
Weight 40 Kg

Features

High resolution

Fully Automated Operation

Fast Throughput

Flexible Sample Handling

Effective Cleaning System

Accurate Sample Injection

Innovative Optical Design

Optional Accessories

Reagent

Model No.Accessory NameSpecification
LMFC-A102-OA1Sheath Fluid10L
LMFC-A102-OA2washing Solution2L
LMFC-A102-OA3Shutdown Solution2L
LMFC-A102-OA4Buffer200mL
LMFC-A102-OA5Hemolysin200mL

 

Lymphocyte subset T detection (single antibody mixture/single laser 4 anti-4 color)

Model No.Accessory NameTotal Test
LMFC-A102-OA6CD45-FITC100T
LMFC-A102-OA7CD3-PE-Cy5100T
LMFC-A102-OA8CD4-PE-Cy7100T
LMFC-A102-OA9CD8-PE100T

 

Lymphocyte subset T/B/NK detection (single antibody mixture/single laser 5 anti-body 4 color)

Model No.Accessory NameTotal Test
LMFC-A102-OA10CD45-FITC100T
LMFC-A102-OA11CD3-PE-Cy5100T
LMFC-A102-OA12CD16-PE100T
LMFC-A102-OA13CD56-PE100T
LMFC-A102-OA14CD19 (-PE-Cy7)100T

 

Cytokine detection (7 cytokine)

Model No.Accessory NameTotal Test
LMFC-A102-OA15IFN-γ Assay reagent100T
LMFC-A102-OA16TNF-α Assay reagent100T
LMFC-A102-OA17IL-2 Assay reagent100T
LMFC-A102-OA18IL-4 Assay reagent100T
LMFC-A102-OA19IL-6 Assay reagent100T
LMFC-A102-OA20IL-10 Assay reagent100T
LMFC-A102-OA21IL-17 Assay reagent100T

 

Cytokine detection (10 cytokine)

Model No.Accessory NameTotal Test
LMFC-A102-OA22IFN-γ Assay reagent100T
LMFC-A102-OA23IL-1β Assay reagent100T
LMFC-A102-OA24IL-2 Assay reagent100T
LMFC-A102-OA25IL-4 Assay reagent100T
LMFC-A102-OA26IL-6 Assay reagent100T
LMFC-A102-OA27IL-8 Assay reagent100T
LMFC-A102-OA28IL-10 Assay reagent100T
LMFC-A102-OA29IL-17 Assay reagent100T
LMFC-A102-OA30IL-12p70 Assay reagent100T
LMFC-A102-OA31TNF-α Assay reagent100T

 

Cytokine detection (12 cytokine)

Model No.Accessory NameTotal Test
LMFC-A102-OA32IFN-α Assay reagent100T
LMFC-A102-OA33IFN-γ Assay reagent100T
LMFC-A102-OA34IL-1β Assay reagent100T
LMFC-A102-OA35IL-2 Assay reagent100T
LMFC-A102-OA36IL-4 Assay reagent100T
LMFC-A102-OA37IL-5 Assay reagent100T
LMFC-A102-OA38IL-6 Assay reagent100T
LMFC-A102-OA39IL-8 Assay reagent100T
LMFC-A102-OA40IL-10 Assay reagent100T
LMFC-A102-OA41IL-17 Assay reagent100T
LMFC-A102-OA42IL-12p70 Assay reagent100T
LMFC-A102-OA43TNF-α Assay reagent100T

 

Sperm DNA Assay reagent

Model No.Accessory NameTotal Test
LMFC-A102-OA44Sperm nuclear DNA staining solution100T
LMFC-A102-OA45Sperm mitochondrial staining solution100T
LMFC-A102-OA46Sperm acrosome staining solution (calcium carrier induced fluorescence staining)100T

 

HL-B27 assay reagent (Ankylosing spondylitis HLA-B27)

Model No.Accessory NameTotal Test
LMFC-A102-OA47HLA-B27-FITC/HLA-B7-PE (ankylosing spondylitis detection reagent) and IgG2a-FITC/IgG1-PE (Ankylosing spondylitis
concentric antibody reagent)
50T

 

Regulatory T cell Assay reagent

Model No.Accessory NameTotal Test
LMFC-A102-OA48CD4 Assay reagent100T
LMFC-A102-OA49CD25 Assay reagent100T
LMFC-A102-OA50CD127 Assay reagent100T

 

PNH detection of paroxysmal nocturnal haemoglobinuria

Model No.Accessory NameTotal Test
LMFC-A102-OA51CD235a Assay reagent100T
LMFC-A102-OA52CD59 Assay reagent100T

 

PD-1 Assay reagent

Model No.Accessory NameTotal Test
LMFC-A102-OA53CD3 Assay reagent100T
LMFC-A102-OA54CD45 Assay reagent100T
LMFC-A102-OA55PD-1 Antibody reagent
(immunohistochemistry)
100T

 

Hematopoietic stem cell Assay reagent

Model No.Accessory NameTotal Test
LMFC-A102-OA56CD45 Assay reagent100T
LMFC-A102-OA57

CD34 Antibody reagent

(immunohistochemistry)

100T

 

Auxiliary reagent

Model No.Accessory NameTotal Test
LMFC-A102-OA58Cell control IMMUNO-TROL Cells60T
LMFC-A102-OA59Flow cytometer quality control Flow-Check Fluorospheres100T
LMFC-A102-OA60Microsphere reagent for absolute counting Kit FLOW-COUNT FLUOROSPHERES500T
LMFC-A102-OA61Eight Peaks microsphere Sphero Rainbow Calibration particles100T
LMFC-A102-OA62Flow tube12*75mm

Applications

Flow Cytometer LMFC-A102 performs immune cell analysis, including T cell tracking, supports stem cell research, and enhances tumour identification.

Selection Guide

Flow Cytometer LMFC-A102 is designed to meet the needs of advanced research studies that require high sensitivity and multi-laser flexibility. It supports up to three lasers, 405 nm, 488 nm, and 638 nm, allowing simultaneous multi-parametric analysis, which is suitable for complex immunophenotyping, cell cycle analysis, and rare event detection. With APD-type detectors, this system offers superior sensitivity, achieving fluorescence detection limits of <50 MESF for FITC, <30 MESF for PE, and <30 MESF for APC. The high fluorescence linearity (≥0.99) ensures accurate quantitative measurements, essential for consistent and reproducible results. This model is suitable for applications in immunology, oncology, and stem cell research. Additionally, compliance with international quality certifications ensures it meets laboratory standards for regulated and academic research.

Similar Products

Flow Cytometer LMFC-A101

  • Laser: 488 nm solid
  • Detector: FSC, SSC, FL1-FL5
  • Fluorescence Channel: FL1: 525/50 (FITC), FL2: 585/40 (PE), FL3: 630/30 (PE- Texas Red/ECD/PI), FL4: 697/60 (PerCP/PE-Cy5/PE-Cy5.5), FL5: 780/60 (PE-Cy7)
  • Sensitivity: FITC ≤ 100 MESF; PE ≤ 50 MESF
  • Linearity: ≥ 0.99

Frequently Asked Questions

1 What is a Flow cytometer?

A Flow cytometer is a laboratory apparatus designed to analyze the physical and chemical characteristics of cells or particles in a fluid stream.

2 How does Flow cytometer work?

It works by suspending cells or particles in a liquid and sending them through a flow chamber where they are individually exposed to a laser beam.

3 What types of samples can be analyzed using Flow cytometer?

It can analyze wide variety of samples such as blood, cultured cells, microorganisms and other particulate suspensions.

4 Can Flow cytometer analyze multiple parameters at once?

It is used to analyze multiple parameters simultaneously by detecting fluorescence and light scatter from cells or particles.

5 What characteristics can be measured using Flow cytometer?

It can measure various characteristics of individual cells such as size, granularity, surface and intracellular markers as well as nucleic acid content.

6 What kind of maintenance is required by Flow cytometer?

Regular maintenance includes cleaning of fluidics systems, calibrating lasers and ensuring software update.

7 What is the role of antibodies in Flow cytometer?

Antibodies conjugated with fluorochromes are used in Flow cytometer to specifically bind to target molecules thereby allowing their detection and analysis.

8 Can Flow cytometer be used for drug screening?

It is used in drug screening to assess drug effects on cell viability, apoptosis, gene expression and cell signaling pathways.