Get Quote
Contact us now to receive a detailed quotation.
Overview
Flow Cytometer LMFC-A102 offers high performance with flexible configuration, supporting up to 3 lasers and 15 fluorescence channels. It can measure up to 18 different parameters at once, which ensures in-depth profiling of complex samples. Equipped with a precision pump system for consistent, volume based absolute cell counting. Engineered for high efficiency spectral separation with minimal filters and precise detection sensitivity. Our Flow Cytometer supports tube rotaries and microplates with integrated mixing function.
Features :
High resolution
Fully Automated Operation
Fast Throughput
Flexible Sample Handling
Effective Cleaning System
Accurate Sample Injection
Innovative Optical Design
Specifications :
| Laser configuration | Supports up to three lasers: 405 nm (100 mW), 488 nm (60 mW), and 638 nm (80 mW) |
| Detector | APD Type |
| Fluorescence detection limit | FITC < 50MESF; PE < 30MESF; APC < 30MESF |
| Fluorescence linearity | ≥ 0.99 |
| Instrument resolution | < 2% |
| Forward scattered light resolution | < 0.45 μm |
| Detection particle range | 0.2 – 50 μm |
| Carry over rate | < 0.1% |
| Detection speed | > 50000 events/s |
| Absolute count | Compatible with volumetric and microsphere absolute counting |
| Signal range | Maximum 10⁷ |
| Preset Injection speed | Low: 15 μL/min; Medium: 30 μL/min; |
| Adjustable Injection Speed | 15–120 μL/min |
| Threshold setting | Supports dual thresholds to minimize cell debris |
| Fluorescence compensation | Online, offline, and visual compensation modes |
| Project template | Support project template, One-click recall, and fluorescence settings |
| Instrument quality control | Automatic daily QC inspection, tracking, and recording through Levey Jennings |
| Manual Sample Injection Mode | Single tube manual sampling |
| Automated Sample Injection Mode | 40 tubes auto sampler |
| Microplate Compatibility | 96-hole plates |
| Software | English interface for real-time data capture and analysis. |
| File format | Supports FCS 3.1, FCS 3.0, and FCS 2.0 file formats |
| Maintenance method | shutdown cleaning, cleaning between experiments, bubble exhaust, and monthly deep cleaning via automatic procedures. |
| Size (L×W×H) | 760mm × 450mm × 470mm |
| Weight | 40 Kg |
Optional Accessories :
Reagent
| Model No. | Accessory Name | Specification |
| LMFC-A102-OA1 | Sheath Fluid | 10L |
| LMFC-A102-OA2 | washing Solution | 2L |
| LMFC-A102-OA3 | Shutdown Solution | 2L |
| LMFC-A102-OA4 | Buffer | 200mL |
| LMFC-A102-OA5 | Hemolysin | 200mL |
Lymphocyte subset T detection (single antibody mixture/single laser 4 anti-4 color)
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA6 | CD45-FITC | 100T |
| LMFC-A102-OA7 | CD3-PE-Cy5 | 100T |
| LMFC-A102-OA8 | CD4-PE-Cy7 | 100T |
| LMFC-A102-OA9 | CD8-PE | 100T |
Lymphocyte subset T/B/NK detection (single antibody mixture/single laser 5 anti-body 4 color)
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA10 | CD45-FITC | 100T |
| LMFC-A102-OA11 | CD3-PE-Cy5 | 100T |
| LMFC-A102-OA12 | CD16-PE | 100T |
| LMFC-A102-OA13 | CD56-PE | 100T |
| LMFC-A102-OA14 | CD19 (-PE-Cy7) | 100T |
Cytokine detection (7 cytokine)
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA15 | IFN-γ Assay reagent | 100T |
| LMFC-A102-OA16 | TNF-α Assay reagent | 100T |
| LMFC-A102-OA17 | IL-2 Assay reagent | 100T |
| LMFC-A102-OA18 | IL-4 Assay reagent | 100T |
| LMFC-A102-OA19 | IL-6 Assay reagent | 100T |
| LMFC-A102-OA20 | IL-10 Assay reagent | 100T |
| LMFC-A102-OA21 | IL-17 Assay reagent | 100T |
Cytokine detection (10 cytokine)
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA22 | IFN-γ Assay reagent | 100T |
| LMFC-A102-OA23 | IL-1β Assay reagent | 100T |
| LMFC-A102-OA24 | IL-2 Assay reagent | 100T |
| LMFC-A102-OA25 | IL-4 Assay reagent | 100T |
| LMFC-A102-OA26 | IL-6 Assay reagent | 100T |
| LMFC-A102-OA27 | IL-8 Assay reagent | 100T |
| LMFC-A102-OA28 | IL-10 Assay reagent | 100T |
| LMFC-A102-OA29 | IL-17 Assay reagent | 100T |
| LMFC-A102-OA30 | IL-12p70 Assay reagent | 100T |
| LMFC-A102-OA31 | TNF-α Assay reagent | 100T |
Cytokine detection (12 cytokine)
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA32 | IFN-α Assay reagent | 100T |
| LMFC-A102-OA33 | IFN-γ Assay reagent | 100T |
| LMFC-A102-OA34 | IL-1β Assay reagent | 100T |
| LMFC-A102-OA35 | IL-2 Assay reagent | 100T |
| LMFC-A102-OA36 | IL-4 Assay reagent | 100T |
| LMFC-A102-OA37 | IL-5 Assay reagent | 100T |
| LMFC-A102-OA38 | IL-6 Assay reagent | 100T |
| LMFC-A102-OA39 | IL-8 Assay reagent | 100T |
| LMFC-A102-OA40 | IL-10 Assay reagent | 100T |
| LMFC-A102-OA41 | IL-17 Assay reagent | 100T |
| LMFC-A102-OA42 | IL-12p70 Assay reagent | 100T |
| LMFC-A102-OA43 | TNF-α Assay reagent | 100T |
Sperm DNA Assay reagent
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA44 | Sperm nuclear DNA staining solution | 100T |
| LMFC-A102-OA45 | Sperm mitochondrial staining solution | 100T |
| LMFC-A102-OA46 | Sperm acrosome staining solution (calcium carrier induced fluorescence staining) | 100T |
HL-B27 assay reagent (Ankylosing spondylitis HLA-B27)
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA47 | HLA-B27-FITC/HLA-B7-PE (ankylosing spondylitis detection reagent) and IgG2a-FITC/IgG1-PE (Ankylosing spondylitis concentric antibody reagent) | 50T |
Regulatory T cell Assay reagent
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA48 | CD4 Assay reagent | 100T |
| LMFC-A102-OA49 | CD25 Assay reagent | 100T |
| LMFC-A102-OA50 | CD127 Assay reagent | 100T |
PNH detection of paroxysmal nocturnal haemoglobinuria
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA51 | CD235a Assay reagent | 100T |
| LMFC-A102-OA52 | CD59 Assay reagent | 100T |
PD-1 Assay reagent
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA53 | CD3 Assay reagent | 100T |
| LMFC-A102-OA54 | CD45 Assay reagent | 100T |
| LMFC-A102-OA55 | PD-1 Antibody reagent (immunohistochemistry) | 100T |
Hematopoietic stem cell Assay reagent
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA56 | CD45 Assay reagent | 100T |
| LMFC-A102-OA57 | CD34 Antibody reagent (immunohistochemistry) | 100T |
Auxiliary reagent
| Model No. | Accessory Name | Total Test |
| LMFC-A102-OA58 | Cell control IMMUNO-TROL Cells | 60T |
| LMFC-A102-OA59 | Flow cytometer quality control Flow-Check Fluorospheres | 100T |
| LMFC-A102-OA60 | Microsphere reagent for absolute counting Kit FLOW-COUNT FLUOROSPHERES | 500T |
| LMFC-A102-OA61 | Eight Peaks microsphere Sphero Rainbow Calibration particles | 100T |
| LMFC-A102-OA62 | Flow tube | 12*75mm |
Applications :
Flow Cytometer LMFC-A102 performs immune cell analysis, including T cell tracking, supports stem cell research, and enhances tumour identification.
Selection Guide :
Flow Cytometer LMFC-A102 is designed to meet the needs of advanced research studies that require high sensitivity and multi-laser flexibility. It supports up to three lasers, 405 nm, 488 nm, and 638 nm, allowing simultaneous multi-parametric analysis, which is suitable for complex immunophenotyping, cell cycle analysis, and rare event detection. With APD-type detectors, this system offers superior sensitivity, achieving fluorescence detection limits of <50 MESF for FITC, <30 MESF for PE, and <30 MESF for APC. The high fluorescence linearity (≥0.99) ensures accurate quantitative measurements, essential for consistent and reproducible results. This model is suitable for applications in immunology, oncology, and stem cell research. Additionally, compliance with international quality certifications ensures it meets laboratory standards for regulated and academic research.