Soxhlet Extractor Fat Analyzer LMSFA-A401

Soxhlet Extractor Fat Analyzer LMSFA-A401

Soxhlet Extractor Fat Analyzer LMSFA-A401 obeys Soxhlet extraction process of weight method to estimate the fat present in the sample. The analysis is done with in the temperature range of +5 to 300 ℃ with ±1℃ accuracy. Most important 5 technique of extraction are used to give the accurate amount of fats present in the sample. The metal unit is completely heat able and have access to controlled flow water temperature. It is provided with leak detection system for the safety of the user and the samples.

Get Quote
Temperature range Room temperature +5 ℃to 300 ℃
Measuring Range 0.1 to 100%
Temperature accuracy ±1℃
Reproducibility Relative error 1%
Sample weight 0.5 to 15 g
Capacity per batch 6 pcs/batch
Display 7 inches color touch screen
Solvent cup volume 150 mL
Solvent recovery ≥85%
Controller External via cable
Power Supply 220 VAC±10%, 50 Hz
Power 2.6 KW
Dimensions (L×W×H) mm 650×380×720
Net Weight 50 Kg

point.png The entire heating module, which has the advantages of rapid warming, good effect and low power consumption

point.png For environmental and economic reasons, full temperature and flow control is available

point.png To assure experiment safety, it is built-in with leak detection mechanism

point.png Effortless resolving Analyzer permits its controller to adsorb on any iron-based surface

point.png More humanization with a vertical screen

point.png 5 extraction methods built-in include Soxhlet Extraction, Soxhlet Hot Extraction, Continue Flow Extraction, Hot Extraction, CH Standard methods

point.png Options for common reagents can be pre-set and manipulation can be done with a single click for repeated experiments

point.png It is equipped with glass and PTFE material which has the capability to stop the impurities to attain the reliable results

point.png To meet all demands, apply to all organic solvents

point.png Automatic Soxhlet standard method, which is tailored with glass and PTFE and has a high rate of accuracy and can block all pollutants

point.png One-click start and pause manipulation allows for high proficiency operation

It is widely used in agricultural/ food /chemical /environment and other areas, especially for the drug, soil, sludge, cleaner and other substances in the extraction of soluble organic compounds.

Get Quote for
Soxhlet Extractor Fat Analyzer LMSFA-A401

Fat Analyzer

Labmate offers a fat analyzer that requires absolutely no method development or calibrations. This device can analyze fat in any unknown sample with reference chemistry accuracy and exceptional repeatability. This significant improvement over other rapid and traditional methods (i.e. reference extraction, NIR, and FT-IR) allows for rapid analysis regardless of the percent fat or sample matrix. The ORACLE is suitable for contract laboratories, alternative meat and dairy producers, snack food facilities, and much more.