Dry Bath Incubator LMDRI-C105 has temperature range of 5℃ to 160℃. Equipped with aluminium heating blocks, offering thermal conductivity. It has high performance microcomputer for faster temperature rise. Built with lightweight design for easy movement or storage. Our Incubator is helpful for sample preservation in high-throughput labs. 

Catalog Send Mail Whatsapp

Specifications

Temperature Range RT +5℃ to 160℃
Set Temperature Range 5℃ to 160℃
Heating Time Less than or equal to 15min (from 25℃ to 160℃)
Temperature Accuracy ±0.5℃ (at 40℃) or ±1℃ (at 120℃)
Display Accuracy 0.1°C
Time Range 1 min 99 h 59 min/∞
Maximum Temperature 160°C
Power Supply 300W, AC220V or AC110V, 50/60Hz
Dimension (W × D × H) 260 × 220 × 100 mm
Weight 5.0 kg

Features

Corrosion-resistant

Low maintenance

Automatic alarm system 

Wide time range

Temperature display screen

Applications

Dry Bath Incubator LMDRI-C105 is ideal in molecular biology, clinical laboratory including DNA amplification, serum reactions, electrophoresis in research institutions and pharmaceutical labs. 

Similar Products

Dry Bath Incubator LMDRI-C107

  • Temperature Range: RT.+5℃ to 130℃
  • Set Temperature Range: 5℃ to 130℃
  • Heating Time: Less than or equal to 20 min (from 25℃ to 130℃)
  • Temperature Accuracy: ±0.5℃ (at 40℃) or ±1℃ (at 120℃)
  • Display Accuracy: 0.1°C

Dry Bath Incubator LMDRI-C103

  • Temperature Range: RT +5℃ to 100℃
  • Set Temperature Range: 0℃ to 100℃
  • Heating Time: Less than or equal to 20 min (40°C to 100°C)
  • Temperature Accuracy: Less than or equal to ±0.3°C
  • Display Accuracy: 0.1°C

Dry Bath Incubator LMDR-B100

  • Temp. Control Range: RT+5℃ ~ 150℃
  • Heating time: ≤ 15 min(from 20 ℃ to 150 ℃)
  • Temperature Control accuracy@100°C: ≤ ±0.5℃
  • Block temp difference@40℃: 0.3℃
  • Block temperature Uniformity: ≤±0.3℃
Dual Temperature Dry Bath Incubator LMDBI-A101
  • Temperature Control Range: -10℃ to 105℃
  • Temperature Setting Range: -10℃ to 105℃
  • Heating Speed: Less than or equal to 15 min
  • Maximum Temperature: 105℃
  • Cooling Speed: Less than or equal to 25 min
Dry Bath Incubator LMDRI-C112
  • Temperature Range: RT+5 to 160℃
  • Block Quantity: 1
  • Temperature Accuracy: ±0.5℃ at 40℃, ±1℃ at120℃
  • Temperature Uniformity: ±0.5℃
  • Heating Time: Less than or equal to 15min (from 25℃ to 160℃)

Dry Bath Incubator LMDRI-A104

  • Maximum Temperature: 150℃
  • Temperature Control Range: RT+5℃ to 150℃
  • Temperature Stability at 40℃: ±0.3℃
  • Temperature Stability at 100℃: ±0.5℃
  • Temperature Stability at 120℃: ±1℃

Dry Bath Incubator LMDRI-C104

  • Temperature Range: RT -20℃ to 100℃
  • Set Temperature Range: 0℃ to 100℃
  • Heating Time: Less than or equal to 20 min (25°C to 100°C)
  • Temperature Accuracy: Less than or equal to ±0.3°C
  • Display Accuracy: 0.1°C

Dry Bath Incubator LMDRI-B110

  • Temperature Range: RT -15°C to 100°C
  • Temperature Stability: ±0.5°C
  • Temperature Homogeneity: ±0.5°C
  • Display Accuracy: 0.1°C
  • Heating Time: Less than or equal to 12min
Dry Bath Incubator LMDRI-C110
  • Temperature Range: RT+5℃ to 100℃
  • Set Temperature Range: 0℃ to 100℃
  • Heating Time: Less than or equal to 12 min (from 25℃ to 100℃)
  • Temperature Accuracy: Less than or equal to ±0.3℃ at 37℃
  • Display Accuracy: 0.1°C
Dry Bath Incubator LMDRI-C109
  • Temperature Range: RT+5℃ to 100℃
  • Set Temperature Range: 0℃ to 100℃
  • Heating Time: Less than or equal to 15min (from 25℃ to 100℃)
  • Temperature Accuracy: Less than or equal to ±0.3℃ at 37℃
  • Display Accuracy: 0.1°C

Dry Bath Incubator LMDRI-C114

  • Temperature Range: RT+5 to 130℃
  • Block Quantity: 4
  • Temperature Accuracy: ±0.5℃ at 40℃, ±1℃ at120℃
  • Temperature Uniformity: ±0.5℃
  • Heating Time: Less than or equal to 20min (from 25℃ to 130℃)

Dry Bath Incubator LMDR-B106

  • Temp. Control Range: RT + 5 °C to 160 ℃
  • Temp Accuracy at 40 °C: ± 0.5 °C
  • Temp Accuracy at 120 °C: ± 1 °C
  • Block temperature Uniformity: ± 0.5 °C
  • Display Accuracy: 0.1 °C

Dry Bath Incubator LMDRI-B107

  • Temperature Range: RT +5°C to 100°C
  • Temperature Stability: ±0.5°C
  • Temperature Homogeneity: ±0.5°C
  • Display Accuracy: 0.1°C
  • Heating Time: Less than or equal to 12min
Dry Bath Incubator LMDRI-A101
  • Maximum Temperature: 150℃
  • Temperature Control Range: RT+5℃ to 150℃
  • Temperature Stability at 40℃: ±0.3℃
  • Temperature Stability at 100℃: ±0.5℃
  • Temperature Stability at 120℃: ±1℃
Dry Bath Incubator LMDRI-B100
  • Temperature Setting Range: 0 to 110℃
  • Temperature Control Range: RT+5 to 110℃
  • Block Quantity: 4
  • Temperature Accuracy: Less than or equal to ±0.3℃ at 37℃
  • Temperature Uniformity: Less than or equal to ±0.3℃ at 37℃

Frequently Asked Questions

1 What is a Dry Bath Incubator?

A Dry Bath Incubator is an apparatus that uses a solid, heated metal block to incubate samples at precise temperatures.

2 Can Dry Bath Incubator be used for DNA extraction?

It is commonly used for DNA extraction steps such as lysis, protein digestion, and enzyme incubation at controlled temperatures.

3 How is Dry Bath Incubator used in clinical diagnostics?

In clinical labs, it is used to incubate blood, serum, or plasma samples for enzyme assays, coagulation studies, and biochemical tests.

4 Can Dry Bath Incubator be used for enzyme inactivation?

It is frequently used to inactivate enzymes by maintaining high temperatures for a defined period.

5 Is Dry Bath Incubator suitable for thawing frozen samples?

It can quickly and uniformly thaw frozen biological samples like cell lysates, DNA/RNA solutions, or reagents.

6 Can Dry Bath Incubator assist in isothermal amplification methods?

It is suitable for isothermal nucleic acid amplification techniques such as LAMP, which require consistent, fixed temperatures.

7 How does Dry Bath Incubator help in pharmaceutical testing?

In pharmaceutical labs, it is used for drug stability testing, dissolution studies, and incubation of formulations under controlled conditions.

8 Can Dry Bath Incubator be used in food testing laboratories?

It is used in food testing to incubate samples for microbial detection, enzyme activity analysis, and sample digestion processes.

9 How is Dry Bath Incubator used in forensic science?

It is used to incubate DNA samples, accelerate chemical reactions, or maintain sample integrity under controlled conditions.

10 How does Dry Bath Incubator assist in quality control (QC) labs?

It is used in QC labs to perform temperature-dependent tests such as reagent validation, sample incubation, and product consistency checks.