Cyanide Meter LMCNM-A100 is equipped with a cyanide ion selective electrode for measuring the concentration of cyanide ions. It offers a measuring concentration range of 0.2 to 260 ppm with an accuracy of ± 1 % F.S. Provided with an LCD display and system menu for adjusting parameters. Implements an automated electrode diagnostic feature to maintain sensor performance.
CatalogSpecifications
Cn Measurement Range | 5 × 10⁶ to 0.01 M, 0.2 to 260 ppm |
Cn Measurement Accuracy | ± 1 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Temperature Measurement Range | 0 to 105 °C, 32 to 221 °F |
Temperature Accuracy | ± 0.5 °C, ± 0.9 °F |
Temperature Resolution | 0.1°C |
Temperature Compensation | 0 to 100 °C, 32 to 212 °F |
mV Range | (-1999.9) to 1999.9 mV |
mV Accuracy | ± 0.2 mV |
mV Resolution | 0.1 mV |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L |
Compensation mode | Manual or automatic |
Data Hold Function | Manual or automatic endpoint detection |
Reset Function | Yes |
Stability Condition | Low or high |
Calibration Due | 0 to 31 days |
Power Off | Manual or automatic (10,20,30 minutes) |
Memory | Stores up to 500 sets of data |
Output | USB communication interface |
Connector | BNC |
Display | LCD (130 × 110 mm) |
Power | DC 5 V, using AC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
Pricing
Product | Price | Unit | Action |
---|---|---|---|
Cyanide Meter LMCNM-A100 | $1,512.00 | Each of 1 |
Features
Fitted with a stability indicator for real-time information
Advanced with a reset setting function
Integrated with auto hold function for better recording
Designed with a built-in real-time clock to timestamp events
Enhanced with temperature compensation for accurate results
Upgraded with a calibration due reminder for regular calibration of the meter
Employs USB communication interface for effortless data transfer
Offers direct ion concentration readout for accurate measurement
Standard Accessories
Cyanide ion selective electrode Temperature probe Standard solution (1000 ppm) Ionic strength adjuster (30 mL) USB cable DC 5 V Power adapter
Optional Accessories
Cn ion selective electrode range: 0.2 – 260 ppm Ion standard solutions: 480 mL / bottle Ionic strength adjuster: 480 mL / bottle Temperature probe with sensor
Applications
Cyanide meter is a device designed to measure the concentration of cyanide in a given sample. It finds applications in several fields like environmental monitoring, water treatment, food and beverage industry, mining industry and in research.