Get Quote
Contact us now to receive a detailed quotation.
A real time PCR system amplifies DNA and reads fluorescence in each cycle. The readout shows how much target is present while the run is still going. Small models hold 16 samples. Larger blocks hold 48 or 96 samples. Fluorescence channels range from 2 to 6. Five-channel models detect FAM, HEX, ROX, CY5 and CY5.5. Reaction volume runs from 5 to 100 ul on most models. Two models use Peltier control, with a low end of 4 C. Block temperature reaches 100 C, and one model ramps at 7.0 C per second. Five-channel models scan a channel in 1.5 s. Clinical labs use these systems for pathogen detection. Research labs use them for gene expression and genetic analysis.
Real Time PCR LMRT-A101 Catalog
| Sample Capacity | 96-well Plate,12×8 tube strip,96×0.2 mL single tube |
| Volume | 15 to 100 µL |
| Consumable | 0.2ml tube, 0.2ml 8-tube strips, 0.2ml 96 well plate |
| Temperature | 0 ⁰C to 100 ⁰C |
| Ramp Rate | 7.0 ⁰C/s |
Real Time PCR LMRT-A100 Catalog
| Temperature Range | 48 wells x 0.2 mL |
| Heating rate | 4 – 100 °C |
| Cooling Rate | 4.5 °C/S |
| Temp Accuracy | 3 °C/S |
| Temp Uniformity | ± 0.1 °C |
Real time PCR system LMPCS-801 Catalog
| Throughput | 1 to 96 samples |
| Fluorescence Channels | 6 |
| Fluorescence Scanning Time | 7 seconds |
| Excitation Range | Channel 1: 465 nm, Channel 2: 527 nm, Channel 3: 580 nm, Channel 4: 632 nm, Channel 5: 680 nm, Channel 6: 465 nm |
| Detection Range | Channel 1: 510 nm, Channel 2: 563 nm, Channel 3: 616 nm, Channel 4: 664 nm, Channel 5: 730 nm, Channel 6: 616 nm |
Real time PCR system LMPCS-802 Catalog
| Fluorescence Channels | 4 |
| Sample Capacity (Wells) | 96 |
| Reaction Volume | 0 to 100µL |
| Consumables | 0.2ml 96-well plates; 0.2ml 8-strip tubes, 0.2ml PCR single tube |
| Temperature Range | 0°C to 100°C |
Real time PCR system LMPCS-901 Catalog
| Fluorescence Channels | 2 |
| Sample Capacity (Wells) | 48 |
| Reaction Volume | 5 to 100µL |
| Consumables | 0.2ml 8-strip tubes, 0.2ml PCR single tube |
| Temperature Range | 0°C to 100°C |
Real time PCR system LMPCS-902 Catalog
| Fluorescence Channels | 4 |
| Sample Capacity (Wells) | 48 |
| Reaction Volume | 5 to 100µL |
| Consumables | 0.2ml 8-strip tubes, 0.2ml PCR single tube |
| Temperature Range | 0°C to 100°C |
Real Time PCR System LMPCS-803 Catalog
| Sample Capacity | 96 well×0.2 ml |
| Sample Volume | 20 to 120 µl |
| Heating Method | Peltier |
| Consumables | 0.2 ml PCB 8-Tube Strips, 0.2 ml PCR tube with cap |
| Temperature Range | 4ºC to 100ºC |
Real Time PCR System LMPCS-B100 Catalog
| Sample Capacity | 16 wells×0.2 ml |
| Sample Volume | 20 to 120 µl |
| Consumables | 0.2 ml PCB 8-Tube Strips, 0.2 ml PCR tube with cap |
| Heating Method | Peltier |
| Temperature Range | 4ºC to 99ºC |
Real Time PCR System LMPCS-C101 Catalog
| Sample Capacity | 48 |
| Number Of Channels | 5 |
| Detection Method | Real-time fluorescent quantitative PCR |
| Fluorescent Dyes | FAM/HEX/ROX/CY5/CY5.5 |
| Light Source | High brightness LED |
Real Time PCR System LMPCS-C102 Catalog
| Sample Capacity | 96×0.2ml |
| Number Of Channels | 5 |
| Consumable Type | 0.2 mL 8-strip tubes |
| Reaction Volume | 5 to 100 μL |
| Single Channel Scanning Time | 1.5s |
Real Time PCR System LMPCS-C103 Catalog
| Sample Capacity | 96 |
| Number Of Channels | 5 |
| Consumable Type | 0.2 mL 8-strip tubes |
| Reaction Volume | 5 to 100 μL |
| Single Channel Scanning Time | 1.5s |
Real Time PCR System LMPCS-C100 Catalog
| Sample Capacity | 16 |
| Number Of Channels | 5 |
| Fluorescent Dyes | FAM/HEX/ROX/CY5/CY5.5 |
| Operating System | 7-inch build-in Android system |
| Light Source | High brightness LED |