Get Quote
Contact us now to receive a detailed quotation.
Overview
HPLC System LMHLS-B100 is designed with flow rate range of 0.001 to 9.999 mL/min. It features modular stack construct that allows flexible system configuration for diverse workflows. Equipped with high-pressure dual-plunger pump, it ensures stable solvent flow and gradient delivery. It incorporates temperature-controlled column oven, maintaining consistent separation conditions. Our Liquid Chromatograph is ideal for isolation, detection, and quantification of chemical compounds.
Features :
Real-time display
UV-Vis detector
Low baseline noise
Broad linearity
Compact flow cell
Fixed optical path
Programmable interface
Specifications :
| Flow Rate Range | 0.001 to 9.999 mL/min |
| Flow Rate Error | Less than or equal to 0.5% |
| Infusion Mode | Micro-volume double plunger |
| Maximum Infusion Pressure | 6000 Psi (42 MPa) |
| Column Capacity | 2 × 250 mm chromatographic columns |
| Temperature Control Range | Room temperature +5 ℃ to 70 ℃ |
| Spectral Bandwidth | 6 nm |
| Flow Cell Volume | 8 μL |
| Wavelength Range | 190 to 700 nm |
| Optical Path | 10 mm |
| Flow Rate Stability Error | Less than or equal to 0.2% RSD |
| Gradient Error | ±1% (0 to 100% water/acetone aqueous solution) |
| Pressure Pulsation | Less than or equal to 15 Psi |
| Pump Sealing | 5400 Psi for 10 min, pressure drop Less than or equal to 400 Psi |
| Temperature Accuracy | ±1.0 ℃ |
| Temperature Stability | ±0.1 ℃ |
| Wavelength Indication Error | Less than or equal to ±1 nm |
| Wavelength Repeatability Error | Less than or equal to ±0.1 nm |
| Dynamic Noise | Less than or equal to ±0.75 × 10⁻⁵ AU (methanol, 1 mL/min, 254 nm, 20 ℃) |
| Static Noise | Less than or equal to ±0.5 × 10⁻⁵ AU (empty cell, 1 s response, 20 ℃) |
| Dynamic Baseline Drift | Less than or equal to ±1 × 10⁻⁴ AU/h (methanol, 1 mL/min, 254 nm, 20 ℃) |
| Static Baseline Drift | Less than or equal to 0.5 × 10⁻⁴ AU (empty cell, 1 s response, 20 ℃) |
| Linear Range | Greater than or equal to 10⁴ |
| Minimum Detection Concentration | Less than or equal to 1 × 10⁻⁹ g/mL |
| Qualitative Repeatability | RSD₆ Less than or equal to 0.1% |
| Quantitative Repeatability | RSD₆ Less than or equal to 0.5% |
| Dimensions | 60×260×420 mm |
| Weight | 11kg |
Standard Accessories :
Model No. | Accessory name |
LMHLS-B100-I1 | High Pressure Constant Current Infusion Pump |
LMHLS-B100-I2 | Manual Injection Valve |
LMHLS-B100-I3 | Installation kit |
LMHLS-B100-U1 | UV-Vis Variable Wavelength Detector |
LMHLS-B100-U2 | Ultrasonic Cleaner |
LMHLS-B100-S1 | Software Workstation |
LMHLS-B100-S2 | Special Column for Furfural |
LMHLS-B1000C1 | Centrifuge |
LMHLS-B100-C2 | Computer |
LMHLS-B100-V1 | Vortex Oscillator |
LMHLS-B100-P1 | Printer |
Applications :
HPLC System LMHLS-B100 enables compound separation, detection, and quantification across pharmaceutical quality control, environmental monitoring, chemical analysis, academic research, and routine laboratory testing workflows.