Labmate HPLC System is an analytical tool designed for the precise separation, identification, and quantification of components in complex mixtures. They provide consistent and reliable analytical results. Their intuitive software supports data acquisition, processing, and reporting. These are designed for long-term use in demanding laboratory environments. Our HPLC System are widely used in research, quality control, and industrial applications due to their precision, speed, and versatility.
HPLC System LMHLS-A101 Catalog
| Flow Rate | 0.001 to 10.000 mL/min |
| Accuracy | ±0.2% |
| Precision | RSD less than or equal to 0.075% |
| Max Pressure | 45 MPa (up to 5.000 mL/min), 20 MPa (above 5.001 mL/min) |
| Pressure Accuracy | ±3% or ±0.5 MPa |
HPLC System LMHLS-A100 Catalog
| Maximum Pressure | 42 MPa |
| Flow Range | 0.001 to 10.000 mL/min |
| Flow Accuracy | ± 0.5% |
| Flow Precision | ≤ 0.2% |
| Pressure Fluctuation | ≤ 1% |
HPLC System LMHLS-A200 Catalog
| Flow Rate Range | 0.001 to 10.000 ml/min |
| Maximum Pressure | 40 MPa |
| Maximum Injection Volume | 100 μl (extendable to 1000 μl) |
| Sampler Temperature | 1 to 45°C |
| Sampler Capacity | 120×2 ml vial, compatible with 96-well plates |
HPLC System LMHLS-A201 Catalog
| Flow Rate Range | 0.001 to 10.000 ml/min |
| Maximum Operating Pressure | 45 MPa / 62 MPa |
| Maximum Injection Volume | 100 µl |
| Maximum Column Capacity | 300 mm column, 3 columns |
| Temperature Range | 1 to 45°C |
HPLC System LMHLS-A202 Catalog
| Flow Rate Range | 0.001 to 10.000 ml/min |
| Maximum Operating Pressure | 70 MPa |
| Maximum Injection Volume | 30 µL |
| Temperature Range | 1 to 45℃ |
| Injector Capacity | 120 × 2 mL vials, 96-well plates compatible |
HPLC System LMHLS-A203 Catalog
| Flow Rate Range | 0.001to10.000 ml/min |
| Maximum Operating Pressure | 45 MPa / 62 MPa |
| Maximum Injection Volume | 100 μl |
| Temperature Range | 1 to 45°C |
| Injector Capacity | 120 × 2 ml vials, 96-well plates compatible |
HPLC System LMHLS-A204 Catalog
| Flow Rate Range | 0.001 to 10.000 ml/min |
| Maximum Operating Pressure | 45 MPa / 62 MPa / 70 MPa |
| Maximum Injection Volume | 100 µL |
| Temperature Range | 1°C to 45°C |
| Injector Capacity | 120 × 2ml vials, compatible with 96-well plates |
HPLC System LMHLS-B100 Catalog
| Flow Rate Range | 0.001 to 9.999 mL/min |
| Flow Rate Error | Less than or equal to 0.5% |
| Infusion Mode | Micro-volume double plunger |
| Maximum Infusion Pressure | 6000 Psi (42 MPa) |
| Column Capacity | 2 × 250 mm chromatographic columns |
HPLC System LMHLS-A205 Catalog
| Pump Type | High pressure constant flow pump |
| Solvent Channel | 2 |
| Flow Range | 0.001 to 10.000 mL/min |
| Pump Flow Accuracy | Up to ± 0.3 % |
| Pump Flow Stability | Up to 0.06 % |