Fluorometer LMFMR-A100 is the next generation benchtop dual-channel fluorometers having excitation filters of 365 ± 20 nm and 460 ± 20 nm. It measures ds-DNA concentration with great sensitivity and a lower DNA detection limit of 0.5 ng/µl. Designed to provide fluorescence in the UV and blue channels for accurate determination of sample concentration.
Features :
Designed with 4.3-inch touch screen, small and easy to use
Simple protein, RNA, and DNA measurements in 3 seconds
Detects DNA with high sensitivity with a limit of 0.5 ng/µl
Five orders of magnitude linear dynamic range
Provided with two fluorescence channels for nucleic acid, protein quantitation in one detection
Offers opening system for ease of the user
Adopts PCR tube adapter for efficient operation
Saves at most 1,000 data and output data by USB port
Specifications :
| Dynamic range | Five orders of magnitude |
| Linear dynamic range | R2 >0.995 |
| Processing time | 3s (Once) |
| Light source | UV LED Blue LED |
| Excitation filters | 365 ± 20 nm 460 ± 20 nm |
| Emission filters | 420 to 480 nm (60 nm) 525 to 570 nm (45 nm) |
| Detector | Photodiode |
| Repeatability | < 1.5 % |
| Stability | < 1.5 % |
| Sensitivity | ds DNA: 0.5 ng/ml |
| Dimension (W × D × H) | 194 × 155 × 72.5 mm |
| Weight | 0.4 kg |
Standard Accessories :
Adapter for 0.5 ml qPCR tube
Optional Accessories :
Adapter for 0.2 ml qPCR tube
Applications :
Fluorometer is used to measure concentration of the substances on the basis of fluorescence emitted by them across mineralogy, medicine, and chemical sensors.
Selection Guide :
Fluorometer LMFMR-A100 is a highly sensitive instrument designed for fluorescence-based detection and quantification in various research and laboratory applications. Based on research studies, this model is commonly used in molecular biology, biochemistry, environmental monitoring, and clinical diagnostics, where accurate measurement of fluorescent signals is required. It features a wide dynamic range of five orders of magnitude and a linear dynamic range with R² > 0.995, ensuring reliable and accurate results over a broad concentration span. The processing time of just 3 seconds per measurement supports fast throughput in routine or high-volume testing. Equipped with both UV LED and Blue LED light sources, it is versatile for detecting a wide range of fluorophores. Customers should consider these specifications along with relevant certifications and compliance with laboratory standards when selecting this model for experiments requiring sensitivity, speed, and accuracy.