Get Quote
Contact us now to receive a detailed quotation.
Labmate Constant Temperature and Humidity Incubator is a stainless steel chamber formulated to produce exact simulation of varying climatic conditions. The instrument comes with a user-friendly digital LCD interface for easy operation of parameters. It is equipped with micro-computer control system which ensures synchronized regulation of temperature and humidity. The temperature limiting / over temperature alarm system ascertains the equipment safety. It is highly suitable for checking stability and shelf life of the products in pharmaceutical, electronic, automobile and packaging industry and so on.
Constant Temperature and Humidity Incubator LMTH-A100 Catalog
| Capacity | 80 Liter |
| Temperature Control Range | -5 to 80℃ |
| Humidity Range | 40 to 85% |
| Shelves | 2 pieces |
| Display Resolution | 0.1℃ |
| Temperature Stability | High ±0.5℃, Low ±1℃ |
| Temperature Uniformity | ±2℃ |
| Humidity Accuracy | ±3%RH |
| Ambient Temperature | +5 to 35℃ |
Constant Temperature And Humidity Incubator LMTH-A101 Catalog
| Temp. Control Range | -5~80 °C |
| Display Resolution | 0.1°C |
| Temperature Stability | High ±0.5°C Low ±1°C |
| Temperature Uniformity | ±2°C |
| Humidity Range | 40~85% |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 2100W |
| Ambient Temperature | +5~35°C |
| Electrical Requirement | 220V 50Hz |
Constant Temperature And Humidity Incubator LMTH-A102 Catalog
| Temp. Control Range | -5~80 °C |
| Display Resolution | 0.1°C |
| Temperature Stability | High ±0.5°C Low ±1°C |
| Temperature Uniformity | ±2°C |
| Humidity Range | 40~85% |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 2300W |
| Ambient Temperature | +5~35°C |
| Electrical Requirement | 220V 50Hz |
Constant Temperature And Humidity Incubator LMTH-A103 Catalog
| Temp. Control Range | -5~80 °C |
| Display Resolution | 0.1°C |
| Temperature Stability | High ±0.5°C Low ±1°C |
| Temperature Uniformity | ±2°C |
| Humidity Range | 40~85% |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 3850W |
| Ambient Temperature | +5~35°C |
| Electrical Requirement | 220V 50Hz |
Constant Temperature And Humidity Incubator LMTH-A104 Catalog
| Temp. Control Range | -5~80 °C |
| Display Resolution | 0.1°C |
| Temperature Stability | High ±0.5°C Low ±1°C |
| Temperature Uniformity | ±2°C |
| Humidity Range | 40~85% |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 8050W |
| Ambient Temperature | +5~35°C |
| Electrical Requirement | 220V 50Hz |
Constant Temperature and Humidity Incubator LMTH-C100 Catalog
| Capacity | 50 L |
| Temperature Range | 5 ℃ to 50 ℃ |
| Humidity Range | 50 to 90 % RH |
| Number of Shelves | 2 Pieces |
| Temperature Accuracy | ± 1 ℃ |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 to 9999 min |
| Power Consumption | 300 W |
| Power Supply | AC 220V; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C101 Catalog
| Capacity | 80 L |
| Temperature Range | 5 ℃ to 50 ℃ |
| Humidity Range | 50 to 90 % RH |
| Number of Shelves | 2 Pieces |
| Temperature Accuracy | ± 1 ℃ |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 to 9999 min |
| Power Consumption | 400 W |
| Power Supply | AC 220V; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C102 Catalog
| Capacity | 150 L |
| Temperature Range | 5 ℃ to 50 ℃ |
| Humidity Range | 50 to 90 % RH |
| Number of Shelves | 2 Pieces |
| Temperature Accuracy | ± 1 ℃ |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 to 9999 min |
| Power Consumption | 600 W |
| Power Supply | AC 220V; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C103 Catalog
| Capacity | 250 L |
| Temperature Range | 5 ℃ to 50 ℃ |
| Humidity Range | 50 to 90 % RH |
| Number of Shelves | 2 Pieces |
| Temperature Accuracy | ± 1 ℃ |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 to 9999 min |
| Power Consumption | 700 W |
| Power Supply | AC 220V; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C104 Catalog
| Capacity | 350 L |
| Temperature Range | 5 ℃ to 50 ℃ |
| Humidity Range | 50 to 90 % RH |
| Number of Shelves | 2 Pieces |
| Temperature Accuracy | ± 1 ℃ |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 to 9999 min |
| Power Consumption | 900 W |
| Power Supply | AC 220V; 50 Hz |
Constant Temperature And Humidity Incubator LMTH-C200 Catalog
| Capacity | 70 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 500 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature And Humidity Incubator LMTH-C201 Catalog
| Capacity | 100 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 500 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature And Humidity Incubator LMTH-C202 Catalog
| Capacity | 150 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 600 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C203 Catalog
| Capacity | 180 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 600 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C204 Catalog
| Capacity | 250 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 800 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C205 Catalog
| Capacity | 360 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 900 W |
| Power Supply | AC 220 V; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C206 Catalog
| Capacity | 460 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 1000 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C300 Catalog
| Capacity | 70 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 500 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C301 Catalog
| Capacity | 100 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 500 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C302 Catalog
| Capacity | 150 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 600 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C303 Catalog
| Capacity | 180 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 600 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C304 Catalog
| Capacity | 250 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 800 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C305 Catalog
| Capacity | 360 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 900 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature and Humidity Incubator LMTH-C306 Catalog
| Capacity | 460 L |
| Temperature Range | 5 ℃ - 50 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Humidity Range | 50 - 95 % RH |
| Temperature Resolution | 0.1 ℃ |
| Timer Range | 0 - 9999 min |
| No. of Shelves | 2 Pieces |
| Power Consumption | 1000 W |
| Power Supply | AC 220 V ; 50 Hz |
Constant Temperature And Humidity Incubator LMTH-B100 Catalog
| Temp. Control Range | -10~70 °C |
| Display Resolution | 0.1°C |
| Temperature Stability | High ±0.5°C Low ±1°C |
| Temperature Uniformity | ±2°C |
| Humidity Range | 40~95% |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 2000W |
| Ambient Temperature | +5~35°C |
| Electrical Requirement | 220V 50Hz |
Constant Temperature And Humidity Incubator LMTH-B101 Catalog
| Temp. Control Range | -10~70 °C |
| Display Resolution | 0.1°C |
| Temperature Stability | High ±0.5°C Low ±1°C |
| Temperature Uniformity | ±2°C |
| Humidity Range | 40~95% |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 2100W |
| Ambient Temperature | +5~35°C |
| Electrical Requirement | 220V 50Hz |
Constant Temperature And Humidity Incubator LMTH-B102 Catalog
| Temp. Control Range | -10~70 °C |
| Display Resolution | 0.1°C |
| Temperature Stability | High ±0.5°C Low ±1°C |
| Temperature Uniformity | ±2°C |
| Humidity Range | 40~95% |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 2300W |
| Ambient Temperature | +5~35°C |
| Electrical Requirement | 220V 50Hz |
Constant Temperature And Humidity Incubator LMTH-B103 Catalog
| Temp. Control Range | -10~70 °C |
| Display Resolution | 0.1°C |
| Temperature Stability | High ±0.5°C Low ±1°C |
| Temperature Uniformity | ±2°C |
| Humidity Range | 40~95% |
| Humidity Accuracy | ±3%RH |
| Power Consumption | 3850W |
| Ambient Temperature | +5~35°C |
| Electrical Requirement | 220V 50Hz |
Constant Temperature and Humidity Incubator LMTH-B104 Catalog
| Capacity Volume | 310L |
| Temperature Range | -10℃to 70℃ |
| Temperature Precision | 0.1℃ |
| Temperature Fluctuation | ±0.5℃ |
| Temperature Uniformity | ±2℃ |
| Humidity Range | 10%RHto95%RH |
| Humidity Precision | 1%RH |
| Humidity Fluctuation | ±3.0%RH |
| Humidity Uniformity | ±5.0%RH |
Constant Temperature and Humidity Incubator LMTH-D100 Catalog
| Volume | 150 L |
| Temperature Range | 0 to 80 °C |
| Ambient Temperature | 10 to 30°C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ±0.3 (°C (Heating) ±0.5 °C (Cooling) |
| Temperature Uniformity at 37°C | ± 0.8 °C |
| Timer Range | 0 to 9999 min per hour |
| Number of Shelves | 3 (Standard) 5 (Maximum) |
| Load per Shelf | 15 kg |
Constant Temperature and Humidity Incubator LMTH-D101 Catalog
| Volume | 250 L |
| Temperature Range | 0 to 80 °C |
| Ambient Temperature | 10 to 30°C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ±0.3 (°C (Heating) ±0.5 °C (Cooling) |
| Temperature Uniformity at 37°C | ± 0.8 °C |
| Timer Range | 0 to 9999 min per hour |
| Number of Shelves | 4 (Standard) 7 (Maximum) |
| Load per Shelf | 15 kg |
Constant Temperature and Humidity Incubator LMTH-D102 Catalog
| Volume | 400 L |
| Temperature Range | 0 to 80 °C |
| Ambient Temperature | 10 to 30°C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ±0.3 (°C (Heating) ±0.5 °C (Cooling) |
| Temperature Uniformity at 37°C | ± 0.8 °C |
| Timer Range | 0 to 9999 min per hour |
| Number of Shelves | 4 (Standard) 7 (Maximum) |
| Load per Shelf | 15 kg |
Constant Temperature and Humidity Incubator LMTH-D103 Catalog
| Volume | 800 L |
| Temperature Range | 0 to 80 °C |
| Ambient Temperature | 10 to 30°C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ±0.3 (°C (Heating) ±0.5 °C (Cooling) |
| Temperature Uniformity at 37°C | ± 0.8 °C |
| Timer Range | 0 to 9999 min per hour |
| Number of Shelves | 8 (Standard) 12 (Maximum) |
| Load per Shelf | 15 kg |
Constant Temperature and Humidity Incubator LMTH-D104 Catalog
| Volume | 1000 L |
| Temperature Range | 0 to 80 °C |
| Ambient Temperature | 10 to 30°C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ±0.3 (°C (Heating) ±0.5 °C (Cooling) |
| Temperature Uniformity at 37°C | ± 0.8 °C |
| Timer Range | 0 to 9999 min per hour |
| Number of Shelves | 8 (Standard) 12 (Maximum) |
| Load per Shelf | 15 kg |
Constant Temperature and Humidity Incubator LMTH-D200 Catalog
| Volume | 150 L |
| Temperature Range without humidifying | 0 to 60 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ± 0.5 °C |
| Temperature Uniformity at 37°C | ± 1 °C |
| Humidity Range | 50 to 90% |
| Humidity Fluctuation | ±5 % |
| Timer Range | 0 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D201 Catalog
| Volume | 250 L |
| Temperature Range without humidifying | 0 to 60 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ± 0.5 °C |
| Temperature Uniformity at 37°C | ± 1 °C |
| Humidity Range | 50 to 90% |
| Humidity Fluctuation | ±5 % |
| Timer Range | 0 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D202 Catalog
| Volume | 400 L |
| Temperature Range without humidifying | 0 to 60 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ± 0.5 °C |
| Temperature Uniformity at 37°C | ± 1 °C |
| Humidity Range | 50 to 90% |
| Humidity Fluctuation | ±5 % |
| Timer Range | 0 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D203 Catalog
| Volume | 800 L |
| Temperature Range without humidifying | 0 to 60 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation | ± 0.5 °C |
| Temperature Uniformity at 37°C | ± 1 °C |
| Humidity Range | 50 to 90% |
| Humidity Fluctuation | ±5 % |
| Timer Range | 0 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D300 Catalog
| Volume | 150 L |
| Temperature Range without humidifying | 0 to 70 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.5 °C |
| Temperature Uniformity at 25°C | ± 1 °C |
| Humidity Range | 25% to 95%RH |
| Humidity Fluctuation | ±3 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D301 Catalog
| Volume | 250 L |
| Temperature Range without humidifying | 0 to 70 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.5 °C |
| Temperature Uniformity at 25°C | ± 1 °C |
| Humidity Range | 25% to 95%RH |
| Humidity Fluctuation | ±3 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D302 Catalog
| Volume | 400 L |
| Temperature Range without humidifying | 0 to 70 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.5 °C |
| Temperature Uniformity at 25°C | ± 1 °C |
| Humidity Range | 25% to 95%RH |
| Humidity Fluctuation | ±3 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D303 Catalog
| Volume | 600 L |
| Temperature Range without humidifying | 0 to 70 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.5 °C |
| Temperature Uniformity at 25°C | ± 1 °C |
| Humidity Range | 25% to 95%RH |
| Humidity Fluctuation | ±3 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D304 Catalog
| Volume | 800 L |
| Temperature Range without humidifying | 0 to 70 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.5 °C |
| Temperature Uniformity at 25°C | ± 1.5 °C |
| Humidity Range | 30% to 95%RH |
| Humidity Fluctuation | ±5 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D305 Catalog
| Volume | 1000 L |
| Temperature Range without humidifying | 0 to 70 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.5 °C |
| Temperature Uniformity at 25°C | ± 1.5 °C |
| Humidity Range | 30% to 95%RH |
| Humidity Fluctuation | ±5 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D306 Catalog
| Volume | 1600 L |
| Temperature Range without humidifying | 0 to 70 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.5 °C |
| Temperature Uniformity at 25°C | ± 1.5 °C |
| Humidity Range | 30% to 95%RH |
| Humidity Fluctuation | ±5 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D400 Catalog
| Volume | 150 L |
| Temperature Range without humidifying | -10 to 85 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.3 °C |
| Temperature Uniformity at 25°C | ± 0.8 °C |
| Humidity Range | 15% to 98%RH |
| Humidity Fluctuation | ±2 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D401 Catalog
| Volume | 250 L |
| Temperature Range without humidifying | -10 to 85 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.3 °C |
| Temperature Uniformity at 25°C | ± 0.8 °C |
| Humidity Range | 15% to 98%RH |
| Humidity Fluctuation | ±2 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D402 Catalog
| Volume | 400 L |
| Temperature Range without humidifying | -10 to 85 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.3 °C |
| Temperature Uniformity at 25°C | ± 0.8 °C |
| Humidity Range | 15% to 98%RH |
| Humidity Fluctuation | ±2 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D403 Catalog
| Volume | 800 L |
| Temperature Range without humidifying | 0 to 85 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.3 °C |
| Temperature Uniformity at 25°C | ± 1 °C |
| Humidity Range | 20% to 98%RH |
| Humidity Fluctuation | ±3 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D404 Catalog
| Volume | 1000 L |
| Temperature Range without humidifying | 0 to 85 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.3 °C |
| Temperature Uniformity at 25°C | ± 1 °C |
| Humidity Range | 20% to 98%RH |
| Humidity Fluctuation | ±3 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature and Humidity Incubator LMTH-D405 Catalog
| Volume | 1600 L |
| Temperature Range without humidifying | 0 to 85 °C |
| Temperature Range with humidifying | 10 to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Fluctuation at 25°C | ± 0.3 °C |
| Temperature Uniformity at 25°C | ± 1 °C |
| Humidity Range | 20% to 98%RH |
| Humidity Fluctuation | ±3 % RH |
| Timer Range | 1 to 9999 min/h |
Constant Temperature And Humidity Incubator LMTH-E100 Catalog
| Capacity | 100 L |
| Temperature Control Range | 0 to 70°C |
| Temperature Accuracy Range | ±0.3 to ±0.5°C |
| Temperature Uniformity | ±0.5°C |
| Time Range | 1 to 9999 min |
| Humidity Range | 40 to 95% RH |
| Humidity Accuracy | ±5% RH |
| Temperature Resolution | 0.1°C |
| Humidity Resolution | 1% |
Constant Temperature And Humidity Incubator LMTH-E101 Catalog
| Capacity | 150 L |
| Temperature Control Range | 0 to 70°C |
| Temperature Accuracy Range | ±0.3°C to ±0.5°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C |
| Time Range | 1 to 9999 min |
| Humidity Range | 40 to 95% RH |
| Humidity Accuracy | ±5% RH |
| Humidity Resolution | 1% |
Constant Temperature And Humidity Incubator LMTH-E102 Catalog
| Capacity | 250 L |
| Temperature Control Range | 0 to 70°C |
| Temperature Accuracy Range | ±0.3 to ±0.5°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C |
| Time Range | 1 to 9999 min |
| Humidity Range | 40 to 95% RH |
| Humidity Accuracy | ±5% RH |
| Humidity Resolution | 1% |
Constant Temperature And Humidity Incubator LMTH-E103 Catalog
| Capacity | 500 L |
| Temperature Control Range | 0 to 70°C |
| Temperature Accuracy Range | ±0.3 to ±0.5°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C |
| Time Range | 1 to 9999 min |
| Humidity Range | 40 to 95% RH |
| Humidity Accuracy | ±5% RH |
| Humidity Resolution | 1% |
Constant Temperature And Humidity Incubator LMTH-E104 Catalog
| Capacity | 1000 L |
| Temperature Control Range | 0 to 70°C |
| Temperature Accuracy Range | ±0.3 to ±0.5°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C |
| Time Range | 1 to 9999 min |
| Humidity Range | 40 to 95% RH |
| Humidity Accuracy | ±5% RH |
| Humidity Resolution | 1% |
Constant Temperature And Humidity Incubator LMTH-F100 Catalog
| Capacity | 50L |
| Temperature | -35 to +150℃ |
| Temperature Uniformity | ±1.5K |
| Temperature Accuracy | ±0.01℃ |
| Temperature Fluctuation | ±0.7K |
| Temperature Deviation | ≦±2.0℃ |
| Heat-up Time | –35°C to +150°C, ≥5K/min (no load) |
| Humidity Range | 10%RH to 95%RH |
| Humidity Deviation | ±5.0%RH |