Overview

Ammonia Gas Detector LMAMD-A100 provides detection range of 0 to 100 ppm. It features real-time data display with two standard relay output channels for alarm signaling. Equipped with multiple mounting options, including wall, pipeline, and flow-type setups for flexibility. Incorporates magnetic and remote-control functionality for safe operation in explosion-prone zones. Our Gas Detector monitors NH₃ in industrial, utility, agricultural, and food processing areas.

Features :

Lightweight 

24h online monitoring

Intrinsic safety circuit

Computer connectivity

Die-cast aluminum case

Specifications :

Gas Detected NH₃
Measurement Range 0 to 100 ppm
Detection Principle Electrochemistry
Resolution 0.1ppm
Accuracy Less than or equal to ±2 to 5% FS
Display LED display
Working Temperature Range -20 to 55℃
Working Pressure 86 to 106 kPa
Humidity 0 to 95%RH
Power Dissipation Toxic gas: Less than or equal to 2.5W,
Signal Output 4 to 20mA, RS485
Wireless Transmission LORA
Housing Material Die-cast aluminum
Electrical Interface Standard internal screw thread M20 × 1.5
Protection Grade IP66/68
Explosion-Proof Grade IECEX:Ex db IIC T6 Gb,Ex db ia IIC T6 Gb ;ATEX:Ex db IIC T6 Gb,Ex db ia IIC T6 Gb
Power Supply 24V DC
Dimension 157.8×128.8×69.6 mm
Net Weight 1 Kg
Gross Weight 1.5 Kg

Applications :

Ammonia Gas Detector LMAMD-A100 is employed for continuous NH₃ monitoring in chemical plants, utilities, agricultural storage, and food processing zones, ensuring reliable performance in confined, hazardous, industrial conditions.

Labmate Scientific LLC