Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Biological Safety Cabinet Class II LMBSC-A102

Biological Safety Cabinet Class II LMBSC-A102 offers 0.55 m/s inflow velocity. Its high-efficiency HEPA filter offer delivers 99.995% particle removal. It features automatic UV sterilization with scheduling and timer functions for contamination-free environment. Its stainless-steel interior wall and removable work table ensure durability and easy cleaning. Our Biological Safety Cabinet support microbiological research, safe pathogen handling and cleanroom settings.

Catalog Send Mail Whatsapp

Specifications

Operator Capacity 2
Cleanliness Class Class 100
Inflow Air Velocity 0.55 m/s
Down Airflow Velocity 0.35 m/s
Noise Less than or equal to 67 dB
Vibration Half Peak Value Less than or equal to 5 µm
Illuminance Greater than or equal to 650 Lux
Ambient Temperature 10 to 30 °C
Relative Humidity at 25°C Less than or equal to 70%
Atmospheric Pressure 80 to 105 Pa
Lamp power and quantity 30 W × 1
UV Light power and quantity 40 W × 1
Power Consumption 1450 W
Power Supply 220 V, 50/60 Hz
Height of Rack 630 mm
Inflow HEPA Filter Dimensions 1715 × 475 × 70 mm
Exhaust HEPA Filter Dimensions 1000 × 420 × 70 mm
Internal Dimensions 1680 × 580 × 595 mm
Housing Dimensions 1820 × 770 × 2135 mm
Package Dimensions 2080 × 970 × 1690 mm
Net Weight 280 kg
Gross Weight 322 kg

Pricing

Product Price Unit Action
Biological Safety Cabinet Class II LMBSC-A102 $ 8250 Each of 1

Features

Intelligent Airflow Monitoring

LCD Display Screen

Lighting Interlocking Protection

Visual Front Window

10° front tilt angle

Anti Splash AC Socket

Filter Failure Alarm

Optional Accessories

Model No

Accessory

LMBSC-A102-F1

ULPA Filter

Applications

Biological Safety Cabinet Class II LMBSC-A102 is ideal for sterile processing, microbiological research, safe pathogen handling and cleanroom settings.

Similar Products

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A213

  • Cabinet Size: 79 Inches
  • Inflow Volume: 690 m³/h
  • Downflow Volume: 995 m³/h
  • Exhaust Volume: 690 m³/h
  • UV Lamp: 40 W

$ 10000 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A211

  • Cabinet Size: 74 Inches
  • Inflow Volume: 655 m³/h
  • Downflow Volume: 940 m³/h
  • Exhaust Volume: 655 m³/h
  • UV Lamp: 40 W

$ 8750 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A205

  • Maximum Opening: 480 mm
  • Tested Opening: Safety height 200 mm (8 inches)
  • Inflow Velocity: 0.53± 0.025m/s
  • Downflow Velocity: 0.33± 0.025m/s
  • Ulpa Filter: Two, 99.999 % efficiency at 0.12 μm, filter life indicator

$ 5037.5 / Pack of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A212
  • Cabinet Size: 74 Inches
  • Inflow Volume: 824 mm³/h (485 CFM)
  • Downflow Volume: 1212 m³/h (713 CFM)
  • Exhaust Volume: 824 m³/h 485 CFM)
  • UV Lamp: Germicidal UV Lamp (40 W)

$ 8750 / Pack of 1

Biological Safety Cabinet Class II LMBSC-A100
  • Operator Capacity: 1
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 6125 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A206

  • Cabinet Size: 55 Inches
  • Inflow Volume: 462 m³/h(272 CFM)
  • Downflow Volume: 863 m³/h (507 CFM)
  • Exhaust Volume: 462 m³/h (272 CFM)
  • UV Lamp: 30 W

$ 6250 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A209

  • Cabinet Size: 59 Inches
  • Inflow Volume: 520 m3/h
  • Downflow Volume: 746 m³/h
  • Exhaust Volume: 500 m³/h
  • UV Lamp: 30 W

$ 6750 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A204

  • Cabinet Size: 44 Inches
  • Inflow Volume: 360 m3/h
  • Downflow Volume: 520 m³/h
  • Exhaust Volume: 360 m³/h
  • UV Lamp: 30 W

$ 6125 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A207
  • Cabinet Size: 55 Inches
  • Inflow Volume: 462 m3/h (272 CFM)
  • Downflow Volume: 863 m³/h(507 CFM)
  • Exhaust Volume: 462 m³/h (272 CFM)
  • UV Lamp: Germicidal UV Lamp (30 W)

$ 6250 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A208
  • Cabinet Size: 55 Inches
  • Inflow Volume: 587 m³/h (346 CFM)
  • Downflow Volume: 863 m³/h (507 CFM)
  • Exhaust Volume: 587m³/h (346 CFM)
  • UV Lamp: Germicidal UV Lamp (30 W)

$ 6250 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A210

  • Cabinet Size: 74 Inches
  • Inflow Volume: 649 m³/h(382 CFM)
  • Downflow Volume: 1212 m³/h (713 CFM)
  • Exhaust Volume: 649 m³/h (382 CFM)
  • UV Lamp: Germicidal UV Lamp (18 W)

$ 8750 / Each of 1

Biological Safety Cabinet Class II LMBSC-A104

  • Operator Capacity: 2
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 8500 / Each of 1

Biological Safety Cabinet Class II LMBSC-A101

  • Operator Capacity: 2
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 6500 / Each of 1

Biological Safety Cabinet Class II LMBSC-A103
  • Operator Capacity: 1
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 8250 / Each of 1

Frequently Asked Questions

1 What is a Biological Safety Cabinet Class II Type A2?

A Biological Safety Cabinet Class II Type A2 is a ventilated laboratory workspace designed to protect personnel, product and the environment from biohazardous or infectious agents.

2 Can chemicals be used in Biological Safety Cabinet Class II Type A2?

Small amounts of non-volatile chemicals can be safely used in Biological Safety Cabinet Class II Type A2.

3 How does Biological Safety Cabinet Class II Type A2 work?

It utilizes HEPA filters and airflow patterns to contain and filter biohazards.

4 Can Biological Safety Cabinet Class II Type A2 be used to perform cell culture?

It is widely used for sterile cell culture procedures to prevent contamination.

5 Is Biological Safety Cabinet Class II Type A2 suitable for handling blood samples?

It is commonly used for handling blood and other clinical specimens.

6 Is Biological Safety Cabinet Class II Type A2 used in vaccine development?

It is often used in vaccine research and development for handling live attenuated or inactivated viruses.

7 Can Biological Safety Cabinet Class II Type A2 be used for antibiotic testing?

It is widely used for antibiotic testing.

8 Is Biological Safety Cabinet Class II Type A2 used in pharmaceutical compounding?

It is used for non-hazardous compounding where product sterility and personnel protection are required.

9 Can Biological Safety Cabinet Class II Type A2 be used in IVF labs?

It is used to protect embryos and cultures from contamination.

10 Can Biological Safety Cabinet Class II Type A2 be used for forensic biology?

It is used to protect DNA samples from contamination.