Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A205

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A205 operates with a maximum opening width of 480 mm and a testing safety height of 200 mm, facilitating easy access. Integrates HEPA filters, which operate with 99.99% efficiency for effective filtration. Negative pressure inside the cabinet ensures inward airflow, preventing contaminants from escaping. Provided with an interlock function for the coordinated operation of the UV lamp, front window, and blower.

Catalog Send Mail Whatsapp

Specifications

Maximum Opening 480 mm
Tested Opening Safety height 200 mm (8 inches)
Inflow Velocity 0.53± 0.025m/s
Downflow Velocity 0.33± 0.025m/s
Ulpa Filter Two, 99.999 % efficiency at 0.12 μm, filter life indicator
Pre-Filter Washable
Front Window Motorized, two-layer laminated toughened glass ≥ 6 mm, anti UV
Noise ≤ 65dB
UV Lamp 30W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination
LED Lamp 14 W ×2
Illumination ≥ 1000Lux
Consumption 8000W
Display LCD
Waterproof Sockets Two and total load of 2 sockets is ≤ 500 W
Control System Microprocessor
Airflow System 70 % air recirculation, 30 % air exhaust
Work Zone Material 304 stainless steel
Main Body Material cold-rolled steel with anti-bacterial powder coating
Work Surface Height 770mm can be customized
Caster Foot master caster
Power Supply AC 220V±10%, 50/60 Hz; 110V±10 %, 60 Hz
Internal Dimension (W×D×H) 1150×600×660mm
External Dimension (W×D×H) 1300×755×2200mm
Packaging Dimensions (W×D×H) 1430×1060×1840mm
Weight 280kg

Pricing

Product Price Unit Action
Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A205 $ 5037.5 Pack of 1

Features

Automatic air speed adjustment
Large digital color display for monitoring
Double-trigger UV activation
Universal caster with brake and travelling feet
Memory function for power failure
Remote control & alarm
Adjustable front window height by foot

Standard Accessories

LED lamp2pcs
UV Lamp1pcs
Base stand1pcs
Remote control1pcs
Footswitch   1pcs
Drain valve1pcs
Waterproof sockets2 pcs

Optional Accessories

Water and gas tap Electric height adjustable base stand Armrest

Similar Products

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A213

  • Cabinet Size: 79 Inches
  • Inflow Volume: 690 m³/h
  • Downflow Volume: 995 m³/h
  • Exhaust Volume: 690 m³/h
  • UV Lamp: 40 W

$ 10000 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A206

  • Cabinet Size: 55 Inches
  • Inflow Volume: 462 m³/h(272 CFM)
  • Downflow Volume: 863 m³/h (507 CFM)
  • Exhaust Volume: 462 m³/h (272 CFM)
  • UV Lamp: 30 W

$ 6250 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A210

  • Cabinet Size: 74 Inches
  • Inflow Volume: 649 m³/h(382 CFM)
  • Downflow Volume: 1212 m³/h (713 CFM)
  • Exhaust Volume: 649 m³/h (382 CFM)
  • UV Lamp: Germicidal UV Lamp (18 W)

$ 8750 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A208
  • Cabinet Size: 55 Inches
  • Inflow Volume: 587 m³/h (346 CFM)
  • Downflow Volume: 863 m³/h (507 CFM)
  • Exhaust Volume: 587m³/h (346 CFM)
  • UV Lamp: Germicidal UV Lamp (30 W)

$ 6250 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A204
  • Cabinet Size: 44 Inches
  • Inflow Volume: 360 m3/h
  • Downflow Volume: 520 m³/h
  • Exhaust Volume: 360 m³/h
  • UV Lamp: 30 W

$ 6125 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A212

  • Cabinet Size: 74 Inches
  • Inflow Volume: 824 mm³/h (485 CFM)
  • Downflow Volume: 1212 m³/h (713 CFM)
  • Exhaust Volume: 824 m³/h 485 CFM)
  • UV Lamp: Germicidal UV Lamp (40 W)

$ 8750 / Pack of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A211

  • Cabinet Size: 74 Inches
  • Inflow Volume: 655 m³/h
  • Downflow Volume: 940 m³/h
  • Exhaust Volume: 655 m³/h
  • UV Lamp: 40 W

$ 8750 / Each of 1

Biological Safety Cabinet Class II LMBSC-A102

  • Operator Capacity: 2
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 8250 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A207
  • Cabinet Size: 55 Inches
  • Inflow Volume: 462 m3/h (272 CFM)
  • Downflow Volume: 863 m³/h(507 CFM)
  • Exhaust Volume: 462 m³/h (272 CFM)
  • UV Lamp: Germicidal UV Lamp (30 W)

$ 6250 / Each of 1

Biological Safety Cabinet Class II LMBSC-A100
  • Operator Capacity: 1
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 6125 / Each of 1

Biological Safety Cabinet Class Ⅱ Type A2 LMBC-A209

  • Cabinet Size: 59 Inches
  • Inflow Volume: 520 m3/h
  • Downflow Volume: 746 m³/h
  • Exhaust Volume: 500 m³/h
  • UV Lamp: 30 W

$ 6750 / Each of 1

Biological Safety Cabinet Class II LMBSC-A101

  • Operator Capacity: 2
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 6500 / Each of 1

Biological Safety Cabinet Class II LMBSC-A104

  • Operator Capacity: 2
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 8500 / Each of 1

Biological Safety Cabinet Class II LMBSC-A103
  • Operator Capacity: 1
  • Cleanliness Class: Class 100
  • Inflow Air Velocity: 0.55 m/s
  • Down Airflow Velocity: 0.35 m/s
  • Noise: Less than or equal to 67 dB

$ 8250 / Each of 1

Frequently Asked Questions

1 What is a Biological Safety Cabinet Class II Type A2?

A Biological Safety Cabinet Class II Type A2 is a ventilated laboratory workspace designed to protect personnel, product and the environment from biohazardous or infectious agents.

2 Can chemicals be used in Biological Safety Cabinet Class II Type A2?

Small amounts of non-volatile chemicals can be safely used in Biological Safety Cabinet Class II Type A2.

3 How does Biological Safety Cabinet Class II Type A2 work?

It utilizes HEPA filters and airflow patterns to contain and filter biohazards.

4 Can Biological Safety Cabinet Class II Type A2 be used to perform cell culture?

It is widely used for sterile cell culture procedures to prevent contamination.

5 Is Biological Safety Cabinet Class II Type A2 suitable for handling blood samples?

It is commonly used for handling blood and other clinical specimens.

6 Is Biological Safety Cabinet Class II Type A2 used in vaccine development?

It is often used in vaccine research and development for handling live attenuated or inactivated viruses.

7 Can Biological Safety Cabinet Class II Type A2 be used for antibiotic testing?

It is widely used for antibiotic testing.

8 Is Biological Safety Cabinet Class II Type A2 used in pharmaceutical compounding?

It is used for non-hazardous compounding where product sterility and personnel protection are required.

9 Can Biological Safety Cabinet Class II Type A2 be used in IVF labs?

It is used to protect embryos and cultures from contamination.

10 Can Biological Safety Cabinet Class II Type A2 be used for forensic biology?

It is used to protect DNA samples from contamination.