Labmate Automated QuEChERS Analyzer LMAQA-A101 accommodates up to 40 test batches per run for higher throughput screening. Integrated with extraction capability completing processes within 3 hours 40 minutes efficiently. Equipped with variable speed control, ranging from 100 to 4500 rpm for various analytical needs. Incorporated with temperature-regulated ice bath to preserve sample quality. Our Automated QuEChERS Analyzer is ideal for detecting pesticide residues in fruits, vegetables, and crops.

Catalog Send Mail Whatsapp

Specifications

Sample Capacity 40 per test
Processing Time 3 hours 40 minutes
Filling Consistency ±0.5% RSD (8-way)
Pipetting Stability Less than or equal to 1ml, ±1% RSD
Salt Addition Uniformity ±5% Relative Standard Deviation (RSD)
Shaking Speed 350 to 500 shakes per min
Centrifuge Speed 100 to 4500 rpm
Centrifuge Capacity 4 tubes per test (50ml/15ml)
Ice Bath Temperature ±1℃
Power Supply AC 220V, 50Hz
Dimensions(W×D×H) 1490×830×2070mm

Pricing

Product Price Unit Action
Automated QuEChERS Analyzer LMAQA-A101

Features

Anti-Clogging Pipette System 

8-Way Switching Valve 

Adjustable Shaking Rate 

Multi-Tube Centrifugation 

Uniform Rotational Agitation

Standard Accessories

Model No.AccessoryUnitQuantity
LMAQA-A101-A1Sample Processing Tubes (50ml/15ml)Pieces40
LMAQA-A101-A2Centrifuge Tube HoldersPieces4
LMAQA-A101-A3Reagent BottlesPieces2
LMAQA-A101-A4Pipette Tips & RacksSet1
LMAQA-A101-A5Shaking PlatformEach1
LMAQA-A101-A6Power AdapterEach1
LMAQA-A101-A7Ice Bath ContainerEach1
LMAQA-A101-A8Waste Collection ContainerEach1
LMAQA-A101-A9Software CDSet1

Applications

Automated QuEChERS Analyzer LMAQA-A101 is essential for detecting veterinary drug residues and monitoring pesticide or chemical traces in beverages such as juice, wine, and soft drinks.

Selection Guide

Automated QuEChERS Analyzer LMAQA-A101 is designed for research studies, food safety testing, and environmental analysis where accurate extraction and cleanup of complex samples are required. It is widely used in applications such as pesticide residue analysis, agricultural product testing, and pharmaceutical research. With a sample capacity of 40 per test and a processing time of 3 hours 40 minutes, this analyzer is suitable for medium- to high-throughput labs seeking automation, consistency, and reduced manual effort. Users such as analytical laboratories, food testing centers, regulatory agencies, and research institutions should select this model for its accuracy, efficiency, and compliance with international standards, including ISO/IEC 17025.

QuEChERS Analyzer with Anti-Clogging Pipette System
QuEChERS Analyzer with Anti-Clogging Pipette System

Similar Products

Automated QuEChERS Analyzer LMAQA-A102

  • Sample Capacity: 60 per test
  • Processing Time: 5 hours 25 minutes
  • Filling Consistency: ±0.5% RSD (8-way)
  • Pipetting Stability: Less than or equal to 1ml, ±1% RSD
  • Salt Addition Uniformity: ±5% Relative Standard Deviation (RSD)

$ 104687.5 / Each of 1

Automated QuEChERS Analyzer LMAQA-A100

  • Sample Capacity: 32 per test
  • Processing Time: 2 hours 40 minutes
  • Filling Consistency: ±0.5% RSD (5-way)
  • Pipetting Stability: Less than or equal to 5ml, ±1% RSD
  • Salt Addition Uniformity: ±5% Relative Standard Deviation (RSD)

$ 79987.5 / Each of 1

Frequently Asked Questions

1 What is an Automated QuEChERS Analyzer?

An Automated QuEChERS Analyzer is an apparatus designed to automate the QuEChERS extraction and cleanup process for pesticide analysis.

2 How does Automated QuEChERS Analyzer work?

It works by automating sample extraction, cleanup and analysis for detecting contaminants such as pesticides in food and environmental samples.

3 What samples can be analyzed using Automated QuEChERS Analyzer?

It is used to analyze food, agricultural products and environmental samples.

4 Can Automated QuEChERS Analyzer handle high volume of samples?

It can process high sample volumes.

5 Can Automated QuEChERS Analyzer be used for both targeted and untargeted screening of contaminants??

It is engineered for both targeted and untargeted screening.

6 Can Automated QuEChERS Analyzer be used for trace analysis?

It is used for detecting trace amounts of contaminants.

7 Can Automated QuEChERS Analyzer be used for both qualitative and quantitative analysis?

It can be used for both qualitative and quantitative analysis.

8 Can Automated QuEChERS Analyzer handle both solid and liquid samples?

It can process both solid and liquid samples.

9 Does Automated QuEChERS Analyzer provide data for both regulatory and research purposes?

It provides accurate data suitable for both regulatory compliance testing and research applications.

10 Can Automated QuEChERS Analyzer handle both volatile and non-volatile contaminants?

It can handle both volatile and non-volatile contaminants.