Automated Cell Counter LMACL-A103 detects and counts cells ranging from 0.5 to 5µm. Calibrated for smaller-sized particles, it ensures high-sensitivity microbial enumeration. Features low concentration limit enabling direct culture-free analysis. Engineered for rapid processing, it delivers reliable results in few seconds. Our Automated Cell Counter with advanced electrical impedance provides efficient sample evaluation.

Catalog Send Mail Whatsapp

Specifications

Particle Size Range 0.5 to 5µm
Sample Volume 10µL
Sample Concentration 5×10⁴ to 2× 10⁷ cells/mL
Detection Time Less than 90s
Data Input and Output USB 2.0
File format CSV, excel
Coefficient of Variation Less than 10%
Dimension 341.5×272×147mm

Pricing

Product Price Unit Action
Automated Cell Counter LMACL-A103 $ 9475 Each of 1

Features

Super-fine microfluidics chip

Pre-filled sheath liquid

Fool-proof chip design

Flow-focused absolute counting

User-friendly interface

Integrated data storage 

Optional Accessories

Model No

Accessory

Unit

Quantity

LMACL-A103-M1

Microbial Counter Chip

Each

1

LMACL-A103-S1

500ml Sheath Liquid 

Each

1

Applications

Automated Cell Counter LMACL-A103 is employed in the detection and counting of a wide range of microorganisms including E. coli, Staphylococcus aureus, Helicobacter pylori, Neisseria meningitidis and Bacillus subtilis.

Selection Guide

Automated Cell Counter LMACL-A103 is a perfect choice for researchers in cell biology, clinical diagnostics, and pharmaceutical applications. It is commonly used for cell viability analysis, proliferation studies, cytotoxicity assays, and monitoring of cell cultures involving mammalian cells and yeast. With a detection time of less than 90 seconds, it enhances lab productivity by delivering quick and accurate results. The USB 2.0 data input and output provide smooth data handling and integration with lab systems. Widely referenced in research studies for consistent and reproducible cell counts, this model is built to meet CE and ISO certification standards, ensuring high quality, safety, and compliance.

Similar Products

Automated Cell Counter LMACL-A105

  • Particle Size Range: 3 to 40µm
  • Sample Volume: 30µL
  • Sample Concentration: 2 × 10⁴ to 1 × 10⁷ cells/mL
  • Detection Time: Less than 30s
  • Dual Detection Channels: 620±30nm/520±25nm

$ 19137.5 / Each of 1

Automated Cell Counter LMACL-B100

  • Amplification Factor: 2.5 × 5 Megapixel
  • Focusing Method: Auto-focus and auto-exposure, with manual adjustment
  • Sample Volume: 10 µL
  • Cell Counting Area: 2.15 mm × 1.62 mm
  • Diameter Range: 4 to 60 µm

$ 5200 / Each of 1

Automated Cell Counter LMACL-A104

  • Particle Size Range: 10 to 120µm
  • Sample Volume: 20µL/50µL
  • Sample Concentration: 1× 10⁴ to 2 × 10⁶ cells/mL
  • Detection Time: 30 to 60s
  • Data Input and Output: USB 2.0

$ 12500 / Each of 1

Automated Cell Counter LMACL-C101
  • Sample Volume: 10 μL or 20 μL
  • Cell Counting Time: Less than 1 second
  • Cell Concentration Range: 1×10⁴ to 3×10⁷ cells/mL
  • Cell Diameter range: 5 to 200μm
  • Viability range: 0 to 100%

$ 5625 / Each of 1

Automated Cell Counter LMACL-A100
  • Particle Size Range: 3 to 30µm
  • Sample Volume: 10µL
  • Sample Concentration: 1×10⁴ to 1×10⁷ cells/mL
  • Detection Time: 20 to 30s
  • Data Input and Output: USB 2.0

$ 8387.5 / Each of 1

Automated Cell Counter LMACL-A101

  • Particle Size Range: 3 to 30µm
  • Sample Volume: 10µL
  • Sample Concentration: 1× 10⁴ to 2×10⁷ cells/mL, Maximum at 4×10⁷ cells /mL
  • Detection Time: 20 to 30s
  • Dye: Trypan-blue

$ 12562.5 / Each of 1

Automated Cell Counter LMACL-C100

  • Sample Volume: 10 µL
  • Cell Counting Time: 30 seconds
  • Cell Concentration Range: 5×104 to 1×107 cells/mL
  • Cell Size Range: Detectable Range: 1 to 90 µmOptimal Range: 5 to 60 µm
  • Excitation Wavelength: 470 ± 20 nm

$ 4662.5 / Each of 1

Automated Cell Counter LMACL-A102

  • Particle Size Range: 3 to 30µm
  • Sample Volume: 10µL
  • Sample Concentration: 1× 10⁴ to 2× 10⁷ cells/mL, Maximum at 4× 10⁷ cells /mL
  • Detection Time: 20 to 30s
  • Dye: Trypan-blue

$ 16737.5 / Each of 1

Frequently Asked Questions

1 What is an Automated Cell Counter?

An Automated Cell Counter is an apparatus designed to quickly and accurately count cells in a sample without manual effort.

2 How does an Automated Cell Counter work?

It works by using imaging or electrical sensing to detect and count cells in a liquid sample.

3 What types of samples can be analyzed by Automated Cell Counter?

It can analyze a variety of biological samples, including mammalian cells, yeast, bacteria, and plant cells.

4 What kind of maintenance does Automated Cell Counter require?

Regular maintenance includes cleaning of sample chambers, updating software and checking for calibration accuracy.

5 How is Automated Cell Counter used in cell culture?

It monitors cell growth, density and viability during routine cell culture.

6 Can Automated Cell Counter be used in pharmaceutical research?

It is widely used in drug screening and cytotoxicity studies in pharma labs.

7 Can Automated Cell Counter be used in clinical diagnostics?

It assists in analyzing blood and body fluid samples for diagnostics.

8 Is Automated Cell Counter used in vaccine production?

It is essential in vaccine production for monitoring cell lines and culture consistency.

9 Can Automated Cell Counter be used in environmental microbiology?

It is used to assess microbial populations in environmental samples with appropriate staining.

10 How does Automated Cell Counter help in toxicity testing?

It measures changes in cell viability and count after exposure to toxins, aiding in toxicology studies.