Automated Cell Counter LMACL-A102 efficiently counts cells using minimal 10µL sample volume. It features automatic staining module for convenient viability detection. Built with high-resolution imaging system, it captures detailed cellular structures. Equipped with dilution calculator, it simplifies concentration adjustments. Our counter differentiates debris and monitors clustering for reliable evaluation.

Catalog Send Mail Whatsapp

Specifications

Particle Size Range 3 to 30µm
Sample Volume 10µL
Sample Concentration 1× 10⁴ to 2× 10⁷ cells/mL, Maximum at 4× 10⁷ cells /mL
Detection Time 20 to 30s
Dye Trypan-blue
Image Magnification 5X
Data Input and Output USB 2.0
Coefficient of Variation Less than 5%

Features

Rapid processing

User-friendly interface

Compact and portable design

Built-in cleaning system

Chip-free operation

Integrated data storage 

Optional Accessories

Model No

Accessory

Unit

Quantity

LMACL-A102-T1

150 ml Trypan Blue

Each

1

LMACL-A102-C1

500 ml Cleaning Liquid

Each

1

Applications

Automated Cell Counter LMACL-A101 is suitable for cell counting, viability assessment, automated staining, morphology analysis, and population distribution study of versatile cell types.

Selection Guide

Automated Cell Counter LMACL-A102 is best suited for laboratories engaged in cell viability studies, apoptosis analysis, and cell proliferation experiments. It is compatible with Trypan Blue dye, enabling precise viability assessments by differentiating live and dead cells through dye exclusion. This model is particularly suited for research involving mammalian cells, yeast, and stem cells, where accurate live/dead cell quantification is crucial. Its advanced imaging and software algorithms provide reliable, rapid analysis, supporting high-throughput applications in pharmaceutical, biomedical, and microbiological research. The system complies with CE and ISO certifications, providing quality standards and performance consistency across regulated environments. Researchers seeking dependable results in viability-based assays and routine culture monitoring will find this device an efficient and compliant solution.

Automated Cell Counter with imaging system
Automated Cell Counter with imaging system

Similar Products

Automated Cell Counter LMACL-C101

  • Sample Volume: 10 μL or 20 μL
  • Cell Counting Time: Less than 1 second
  • Cell Concentration Range: 1×10⁴ to 3×10⁷ cells/mL
  • Cell Diameter range: 5 to 200μm
  • Viability range: 0 to 100%

Automated Cell Counter LMACL-A103

  • Particle Size Range: 0.5 to 5µm
  • Sample Volume: 10µL
  • Sample Concentration: 5×10⁴ to 2× 10⁷ cells/mL
  • Detection Time: Less than 90s
  • Data Input and Output: USB 2.0

Automated Cell Counter LMACL-A105

  • Particle Size Range: 3 to 40µm
  • Sample Volume: 30µL
  • Sample Concentration: 2 × 10⁴ to 1 × 10⁷ cells/mL
  • Detection Time: Less than 30s
  • Dual Detection Channels: 620±30nm/520±25nm
Automated Cell Counter LMACL-A100
  • Particle Size Range: 3 to 30µm
  • Sample Volume: 10µL
  • Sample Concentration: 1×10⁴ to 1×10⁷ cells/mL
  • Detection Time: 20 to 30s
  • Data Input and Output: USB 2.0
Automated Cell Counter LMACL-A101
  • Particle Size Range: 3 to 30µm
  • Sample Volume: 10µL
  • Sample Concentration: 1× 10⁴ to 2×10⁷ cells/mL, Maximum at 4×10⁷ cells /mL
  • Detection Time: 20 to 30s
  • Dye: Trypan-blue

Automated Cell Counter LMACL-C100

  • Sample Volume: 10 µL
  • Cell Counting Time: 30 seconds
  • Cell Concentration Range: 5×104 to 1×107 cells/mL
  • Cell Size Range: Detectable Range: 1 to 90 µmOptimal Range: 5 to 60 µm
  • Excitation Wavelength: 470 ± 20 nm

Automated Cell Counter LMACL-A104

  • Particle Size Range: 10 to 120µm
  • Sample Volume: 20µL/50µL
  • Sample Concentration: 1× 10⁴ to 2 × 10⁶ cells/mL
  • Detection Time: 30 to 60s
  • Data Input and Output: USB 2.0

Automated Cell Counter LMACL-B100

  • Amplification Factor: 2.5 × 5 Megapixel
  • Focusing Method: Auto-focus and auto-exposure, with manual adjustment
  • Sample Volume: 10 µL
  • Cell Counting Area: 2.15 mm × 1.62 mm
  • Diameter Range: 4 to 60 µm

Frequently Asked Questions

1 What is an Automated Cell Counter?

An Automated Cell Counter is an apparatus designed to quickly and accurately count cells in a sample without manual effort.

2 How does an Automated Cell Counter work?

It works by using imaging or electrical sensing to detect and count cells in a liquid sample.

3 What types of samples can be analyzed by Automated Cell Counter?

It can analyze a variety of biological samples, including mammalian cells, yeast, bacteria, and plant cells.

4 What kind of maintenance does Automated Cell Counter require?

Regular maintenance includes cleaning of sample chambers, updating software and checking for calibration accuracy.

5 How is Automated Cell Counter used in cell culture?

It monitors cell growth, density and viability during routine cell culture.

6 Can Automated Cell Counter be used in pharmaceutical research?

It is widely used in drug screening and cytotoxicity studies in pharma labs.

7 Can Automated Cell Counter be used in clinical diagnostics?

It assists in analyzing blood and body fluid samples for diagnostics.

8 Is Automated Cell Counter used in vaccine production?

It is essential in vaccine production for monitoring cell lines and culture consistency.

9 Can Automated Cell Counter be used in environmental microbiology?

It is used to assess microbial populations in environmental samples with appropriate staining.

10 How does Automated Cell Counter help in toxicity testing?

It measures changes in cell viability and count after exposure to toxins, aiding in toxicology studies.