Autorefractor Keratometer LMARM-A102 features spherical range of -20.00D to 20.00D with fine increments. It has Hartmann Type Refractor for high-definition retina imaging and eye measurements. Equipped with automatic horizontal, vertical, and back-force motorized focus for effortless adjustments. Incorporates wide color TFT LCD screen with high brightness, contrast, and smooth touch. Our Keratometer ensures eye examination, vision screening, and refraction assessment.

Catalog Send Mail Whatsapp

Specifications

Spherical Range -20.00D to 20.00D (VD = 12mm, 0.01, 0.06, 0.12, 0.25 Increments)
Cylinder Range 0.00D to 10.00D (0.06, 0.12, 0.25 Increments)
Axis 1° to 180° (±1°)
Cylinder Symbol -, +, ±
Vertex Distances 0.0, 12.0, 13.75, 15.0
Pupillary Distance Range 10 to 86mm
Pupil Distance Range 2.00 to 8.00mm
Mini Pupil Size 2.0mm
Average Measurement Time Less than 0.5 seconds
Maximum Brightness Less than 30uw
Refractive Power 33.00D to 67.0D
Corneal Power 0.00D to to 15.00D (0.06D / 0.12D / 0 25D Increments)
Curvature Radius 5.0 to 10.0mm (±0.01mm)
Monitor 9-inch TFT Touch Screen (Flip)
Printer 57mm Width, Auto Cut
Date Save 10 Group Left/Right Eye
Power Supply AC 100 to 250V, 50/60Hz
Packing Dimensions 680×400×640 mm
Net Weight 22 Kg
Gross Weight 26.5 Kg

Pricing

Product Price Unit Action
Autorefractor Keratometer LMARM-A102 $ 2010 Each of 1

Features

Clear Retina Optics

Flip Monitor

Auto-Cut Printer

Chin Height Control

Data Storage

Applications

Autorefractor Keratometer LMARM-A102 is ideal for eye measurements and imaging for ophthalmology clinics, optometry practices, vision screening, eye research, and detailed retinal examinations in medical settings.

Similar Products

Auto Refractometer LMAR-401

  • Modes: REF mode, KEF mode
  • Pupil Distance: 10 to 85 mm
  • Minimum pupil diameter measurable: 2.0 mm
  • Target: Automatic fogging target
  • Radius of curvature: 5 to 10 mm (0.01mm step)

$ 4400 / Each of 1

Autorefractor Keratometer LMRK-402

  • Refractometer: -20 to +20D(VD=12) 0.125D step, -8 to +8D 0.125D step, 0° to 180° (1°step), 045 to 88 mm,1mm step, 0 mm,12 mm,13.75 mm, ø2.0 mm
  • Keratometer: 5.0 to 10mm(increment:0.01mm), 33.75 to 67.50D(when comer equivalent refractive index is 1.337) (increment selectable from 0.12,0.25D), 0.0 to 0.8D(increment selectable from 0.12,0.25D), 1 to 180° (increment 1°), 2.0 to 14.0mm (increment 0.1mm), 10 measure value for each right and left eye
  • General features: Follow-up colorful fogging chart system, 7 inch TFT LCD, Thermal print, 220V±10% 50 Hz 60 VA, 514mm×284mm×465mm, 15.5KG

$ 4387.5 / Each of 1

Auto Refractometer LMAR-403

  • Range Of Measurement: -20.00 to +20.00D(VD=12) 0.12D/0.25D step, 0.00 to ±10.00D (VD = 12mm) 0.12/0.25D step, 1 to 180° (1°step), 30 to 85 mm, 0.0, 12.0, 13.75, 15.0mm, ø2.0 mm, Automatic fogging
  • Corneal Curvature Measurement: 5.0 to 10mm(increment:0.01mm), 33.00 to 67.00D (0.12,0.25D), 0.00 to 15.00D(0.12,0.25D), 1 to 180° (step 1°), 2.0 to 12.00 mm
  • K/R Mode Of Measurement: Refractive and Keratometer measurement
  • REF Mode Of Measurement: Refractive measurement
  • KEF Mode Of Measurement: Corneal curvature measurement

$ 4350 / Each of 1

Auto Refractometer LMAR-402
  • Measuring Range: Sphere:-20 to +20D(VD=12) 0.12D/0.25D step, Cylinder:-8 to +8D 0.12D 0.12D/0.25D step,Axis:0 to180 ° step: 1 °
  • Pupil Distance: 45 to 88mm, step: 1 mm
  • Vertex Distance: 0mm, 12mm, 13.75 mm
  • Minimum Pupil Size: Ø2.0 mm
  • Chart: Auto fog

$ 3500 / Each of 1

Frequently Asked Questions

1 What is an Auto refractometer?

An Auto refractometer is a fast, reliable tool designed for automated vision testing and prescription accuracy.

2 How does Auto Refractometer work?

It works by projecting light into the eye and measuring how it reflects to calculate refractive error.

3 Is Auto Refractometer suitable for high-volume clinics?

It is ideal for high-volume clinics because it speeds up exams and reduces patient waiting time.

4 What role does Auto Refractometer play in vision screening programs?

It is essential in vision screening programs due to its portability, ease of use, and quick measurement capability.

5 Can Auto Refractometer be used for patients with high myopia or hyperopia?

It is used to measure a wide range of refractive errors, including high levels of myopia and hyperopia.

6 How does Auto Refractometer contribute to workflow efficiency?

It streamlines workflow by automating initial vision testing, allowing clinicians to focus on diagnosis and patient care.

7 How does Auto Refractometer help in pre-testing for refractive surgery?

It offers baseline refractive measurements that assist surgeons in planning procedures like LASIK or PRK.

8 Can Auto Refractometer be used for follow-up in progressive lens users?

It helps monitor changes in prescription needs for patients using progressive lenses over time.

9 Is Auto Refractometer helpful for patients with neurological disorders?

It is used for patients with neurological conditions to assess refractive changes without relying on subjective responses.

10 Can Auto Refractometer assist in screening for visual readiness in pilots or air traffic controllers?

It provides objective, high-precision refraction data critical for occupations requiring acute visual performance.