Measurement Range

Detector Channels

Sample Cell Volume

Testing Speed

Accuracy Error

Wet Laser Particle Size Analyzer

Labmate Wet Laser Particle Size Analyzer offers wide measurement range. They feature advanced optical path design for consistent light scattering measurements. These support automated computer control to simplify operation and ensure repeatable results. Their dustproof and shockproof construction enhances durability in demanding lab environments. Our Wet Laser Particle Size Analyzer is ideal for pharmaceuticals, chemicals, food, mining, and cosmetics industries.

Wet Laser Particle Size Analyzer LMWLA-A100

  • Measurement Range: 0.1 to 800 µm
  • Detector Channels: 96
  • Sample Cell Volume: 190 to 600 mL
  • Testing Speed: Less than 1 minute per test (excluding dispersion)
  • Accuracy Error: Lesser than 0.5%

$ 13750 / Each of 1

Wet Laser Particle Size Analyzer LMWLA-A101

  • Measurement Range: 0.01 to 1000 µm
  • Detector Channels: 96
  • Sample Cell Volume: 190 to 600 mL
  • Testing Speed: Less than 1 minute per test (excluding dispersion)
  • Accuracy Error: Lesser than 0.5%

$ 15250 / Each of 1

Wet Laser Particle Size Analyzer LMWLA-A102
  • Measurement Range: 0.1 to 1250 µm
  • Detector Channels: 90
  • Sample Cell Volume: 190 to 600 mL
  • Testing Speed: Less than 1 minute per test (excluding dispersion)
  • Accuracy Error: Lesser than 0.5%

$ 16250 / Each of 1

Wet Laser Particle Size Analyzer LMWLA-A103
  • Measurement Range: 0.1 to 2000 µm
  • Detector Channels: 70
  • Sample Cell Volume: 190 to 600 mL
  • Testing Speed: Less than 1 minute per test (excluding dispersion)
  • Accuracy Error: Lesser than 0.5%

$ 16875 / Each of 1

Selection Guide for Wet Laser Particle Size Analyzer

When selecting Wet Laser Particle Size Analyzer, customers should consider the measurement range based on their specific application requirements. The analyzer offers flexible measurement ranges, such as 0.01 to 1000 µm, 0.1 to 800 µm, 0.1 to 1250 µm, and 0.1 to 2000 µm, which makes it suitable for a wide variety of particle size distributions in suspensions or emulsions. The detector channels (ranging from 70 to 96) determine resolution and accuracy, while the sample cell volume (190 to 600 mL) provides versatility in sample handling. Additionally, a fast testing speed of under 1 minute per test (excluding dispersion) and an accuracy error of less than 0.5% ensure quick and reliable results. This combination of features helps customers choose the right model depending on their required particle size range, resolution, and throughput needs.