
Get Quote
Contact us now to receive a detailed quotation.
LMVB-601 is a vertical-flow circulating air clean bench that provides protection for samples and work procedures. The unit is equipped with HEPA filters which ensure that surface is 99% free of particles at 0.3 micro particles. The airflow has a constant velocity of 0.3 to 0.5 m/sec minimizing air turbulence within the work zone. It offers a wide range of selection with glass slide wall, highly efficient 40W strong germicidal UV lamp for disinfecting bacteria within 30 minutes.
Catalog Send Mail WhatsappSpecifications
Air Velocity | 0.3 to 0.5m/sec (9-phase controllable) |
Main Filter | ULPA filter (efficient at 0.1micron particles) |
Pre-Filter | High efficiency nylon filter |
Illumination | Fluorescent lamp 20W or40W |
Sterilizing | UV lamp 20W or 40W |
Controller | LCD microprocessor |
Window | High temperature safety glass of thickness 5mm |
Door | Sliding glass door/ Tempered safety glass |
Utility | Air cock, Gas cock, Electric outlets(AC 220V×1EA & 110V×1EA) |
Internal Material | Stainless steel plate |
External Material | Steel plate with powder coating |
Supply Voltage & Frequency | AC 230V, 50/60Hz |
Internal Dimension (W×D×H) | 1000×580×680 mm |
External Dimension (W×D×H) | 1100×820×1890 mm |
Features
Low discharge volume and quite operation mechanism
Specialized sound absorbing materials
High-efficient UV lamp source with strong germicidal power
Stainless steel work surface and glass window assure optimum sanitary working conditions
HEPA filter maximize the optimum cleanness
Audio and visual alarm for over-temperature protection
Zero leak airflow system
Pressure flow, Airflow monitor and control
Ergonomically designed work zone
Rear wall recirculation grill for airflow uniformity
5mm high temperature safety glass
Applications
These are suitable in medical science, pharmacy, agriculture, new composition and electrical industry field.
Similar Products
Frequently Asked Questions
1 What is a Vertical Clean Bench?
A Vertical Clean Bench is a laminar flow workstation that directs filtered air vertically from the top of the unit onto the work surface, providing a sterile environment for contamination-sensitive processes.
2 How does Vertical Clean Bench differ from Horizontal Clean Bench?
A Vertical Clean Bench pushes air downward from a HEPA filter above the work area, whereas a Horizontal Clean Bench directs air horizontally across the work surface.
3 Can Vertical Clean Bench be used for cell culture work?
It is used for non-hazardous cell culture work where product protection is required.
4 Is Vertical Clean Bench appropriate for pharmaceutical compounding?
It is used for non-hazardous pharmaceutical compounding in sterile environments.
5 Can Vertical Clean Bench be used in food testing laboratories?
It is commonly used in food testing labs to ensure that samples remain uncontaminated during microbial or chemical analysis.
6 Can Vertical Clean Bench be used in academic research laboratories?
It is widely used in academic research laboratories for conducting experiments that require a sterile environment, such as microbiology, tissue culture, and chemical prep.
7 Can Vertical Clean Bench be used in quality control (QC) labs?
It is ideal for QC labs in industries like pharmaceuticals, biotech, and food production, where clean conditions are necessary to test samples without introducing contaminants.
8 How does Vertical Clean Bench benefit forensic laboratories?
In forensic labs, it protects evidence from airborne contamination during sample sorting, DNA extraction, and trace material handling.
9 Can Vertical Clean Bench be used during PCR setup?
It is often used during PCR setup to reduce the risk of cross-contamination and ensure the accuracy of amplification results.
10 What role does Vertical Clean Bench play in diagnostics kit assembly?
It is used in the assembly of diagnostic kits to maintain sterility, preventing dust or biological contaminants from affecting reagents or test components.