Ask An Expert

We will Follow up with you within 24 hours.

Petroleum Testing Equipment

Labmate Petroleum Testing Equipment ensures reliable results with temperature range of -40°C to 1000°C. They offer advanced features for viscosity measurement and flashpoint determination. Their robust design supports efficient fuel quality assessment and lubricant analysis. They meet industry standards for dependable performance and consistent reporting. Our Petroleum Testing Equipment are essential for refining processes and petroleum product quality evaluation.

Automatic Distillation Apparatus LMADA-A100

  • Heating power: 2 kW
  • Cooling power: 0.5 kW
  • Steam temperature: 0 to 400 ⁰C
  • Oven temperature: 0 to 500 ⁰C
  • Refrigeration temperature: 0 to 60 ℃

Automatic Thermogravimetric Analyzer LMTGA-A100

  • Temperature Range: Room temperature to 1000 ºC
  • Temperature Resolution: 0.1 ºC
  • Temperature Fluctuation: ±0.1 ºC
  • Heating Rate: 1 to 80 ºC / min
  • Cooling Time: 15min (1000ºC to 100ºC)
Cleaveland Open Cup Flash Point Tester LMFPT-A100
  • Thermometer: 6 ℃ to 400 ℃
  • Scale Division: 2 °C
  • Spout Aperture: 0.6 to 0.8 mm
  • Ambient Temperature: -10 ℃ to 50 ℃
  • Relative Humidity: ≤ 85 %
Asphalt Centrifugal Extractor LMCE-501
  • Capacity: 3000 gram
  • Speed: 0 to 3000 rpm (adjustable)
  • Pot Diameter: 280 mm
  • Power: 220V, 750W
  • Packing size: 470×310×540 mm

Asphalt Centrifugal Extractor LMCE-502

  • Capacity: 1500 gram
  • Speed: 0 to 3000 rpm (adjustable)
  • Pot Diameter: 280 mm
  • Power: 220V, 750W
  • Packing size: 470×310×540 mm

Open Cup Flash & Fire Point Tester LMFPT-B100

  • Ambient Temperature: 10 ℃ to 40 ℃
  • Relative Humidity: ≤ 85 %
  • Temperature Measurement: Ambient temperature to 400 ℃
  • Repeatability: ≤ 4 ℃
  • Test Accuracy: 0.005
Open Cup Flash Point Tester LMFPT-A101
  • Thermometer: 0 ℃ to 360 °C
  • Scale Division: 1°C
  • Ambient Temperature: ≤ 35°C
  • Relative Humidity: ≤ 85 %
  • Outer Crucible-Material: Carbon structural steel
Open Cup Flash Point Tester LMFPT-A102
  • Ambient Temperature: 10℃ to 40°C
  • Relative Humidity: ≤ 80%
  • Temperature Measurement: Ambient temperature to 300°C
  • Repeatability: ≤ 8°C
  • Reproducibility: ≤16°C

Penetrometer LMPM-A100

  • Measurement Range: 0 to 600 penetration scale
  • Timing Controller: 5 sec or 60 sec
  • Time Accuracy: ± 0.1 seconds
  • Resolution: 0.01 mm
  • Penetration Accuracy: ± 1 penetration

Pensky-Martens Flash Point Tester LMPFT-A100

  • Ambient Temperature: ≤ 35 °C
  • Relative Humidity: ≤ 85 %
  • Temperature Range: 5°C to 110°C, each scale division is 0.5°C20°C to 150°C, each scale division is 1.0°C90 °C to 370 °C, each scale division is 2°C
  • Aperture of Ignition Device: 0.8 mm
  • Diameter of Oil Cup: 50.7 to 50.8 mm
Pensky-Martens Flash Point Tester LMPFT-A101
  • Ambient Temperature: 10 °C to 40 °C
  • Relative Humidity: ≤ 80 %
  • Measurement Range: Ambient Temperature to 250°C
  • Flash Point: Lower than 104 °C, error is 2°C,Higher than 104 °C, error is 6°C
  • Resolution: 0.1°C
Pensky-Martens Flash Point Tester LMPFT-A102
  • Ambient Temperature: 10 °C to 40 ℃
  • Relative Humidity: ≤ 80 %
  • Ignition Mode: electron igniter/gas flame
  • Temperature Range: Room Temperature to 300 ℃
  • Resolution: 0.1 ℃

Tag Closed Flash Point Tester LMCFT-A100

  • Temperature Range: -50 to 70°C
  • Viscosity: under 5.5 cSt (mm²/s) at 40°C (104°F) or < 9.5 cSt (mm²/s) at 25°C (77°F)
  • Sample Volume: 50 ml
  • Ambient Temperature Range: 10 to 40°C
  • Humidity: ≤ 85%

Aniline Point Tester LMAPT-A100

  • Measurement Range: Room temperature to 150°C
  • Stirring Speed: 0 to 1200 r/min
  • Heating Power: 25W
  • Interior Dimension: 360 × 250 × 545 mm
  • Exterior Dimension: 370 × 320 × 630 mm
Aniline Point Tester LMAPT-A101
  • Temperature Accuracy: ≤ 0.5 ℃
  • Temperature Range: Room temperature to 200 ℃
  • Power Supply: 5 V
  • Power Consumption: 2 kW
Auto Ignition Point Tester LMAIT-A100
  • Temperature Range: 100°C to 800°C
  • Temperature Accuracy: ±1°C
  • Injection Volume: 0.07 ml per injection
  • Injection Interval: ≥15 minutes
  • Testing Medium: Fire-resistant oil

Closed Cup Flash Point Tester LMCPT-A100

  • Temperature Range: 40 to 350℃
  • Ambient Temperature Range: 10 to 35℃
  • Temperature Sensor: Platinum Resistance
  • Repeatability: 0.5%
  • Accuracy: >110℃: ±2℃ ≤110℃: ±1℃

Water Separability Tester LMWST-A100

  • Temperature Control Range: Room temperature to 100°C
  • Temperature Control Accuracy: ±0.1°C or 0.01°C
  • Timing Range: 0 to 99 minutes
  • Stirring Speed: 1500±15 r/min (sample stirring)
  • Temperature Sensor: Platinum resistance

Frequently Asked Questions

What is Petroleum Testing Equipment?

+

Petroleum Testing Equipment refers to a range of instruments designed to analyze and measure the physical, chemical and performance characteristics of petroleum products such as fuels and lubricants.

Can Petroleum Testing Equipment be used for biofuels?

+

It is used for testing biofuels such as biodiesel, bioethanol and other renewable fuels.

Can Petroleum Testing Equipment be used for crude oil?

+

It is commonly used to analyze crude oil properties such as API gravity, sulfur content, viscosity and distillation profile.

What types of contamination can be detected through Petroleum Testing Equipment?

+

It is used to detect a variety of contaminants such as water, sulfur, particulate matter and microorganisms.

Can Petroleum Testing Equipment be used for testing fuel additives?

+

It is used to assess the chemical composition, concentration and effectiveness of fuel additives.

Can Petroleum Testing Equipment handle hazardous materials?

+

It is engineered to deal with hazardous materials such as flammable or toxic substances.

How can Petroleum Testing Equipment help with fuel efficiency?

+

By analyzing the properties of fuels, it helps in optimizing engine performance, fuel consumption and reducing emissions.

How is Petroleum Testing Equipment calibrated?

+

It is calibrated using Certified Reference Materials (CRMs) and standard procedures.

How does Petroleum Testing Equipment ensure environmental compliance?

+

It ensures environmental compliance by evaluating the chemical composition of products such as fuels, oils and lubricants.

How does Petroleum Testing Equipment help in quality control?

+

It plays a crucial role in quality control by providing accurate measurements and analysis of physical and chemical properties of petroleum products.