Nano Spectrophotometer LMNS-A102 features wavelength range of 190 to 850 nm. Equipped with full-spectrum xenon lamp and touchscreen interface for easy navigation. Incorporated with micro-sample handling, it supports 0.5 µL to 2 µL sample volume for definite and efficient analysis. It offers absorbance reliability and supports USB and SD card data storage. Our Spectrophotometer is ideal for DNA, RNA, and protein quantification in research labs.

Catalog Send Mail Whatsapp

Specifications

Sample Volume 0.5 µl to 2 µl
Path Length 0.03 mm, 0.1 mm, 0.2 mm, 1 mm, 1.2 mm
Light Source Xenon Lamp
Detector Type 2048 CMOS Array
Wavelength Range 180 to 910 nm
Wavelength Accuracy ±1 nm
Wavelength Resolution less than or equal to 1.5 nm
Absorbance Range 0.04 to 750 (10 mm path length at 260 nm)
Absorbance Accuracy ±1%
Absorbance Precision 0.002 Abs
Nucleic Acid Range 2 to 37500 ng/µl dsDNA
Protein Range 0.06 to 1119 mg/ml BSA, 0.03 to 547 mg/ml IgG
Detection Time less than 6 seconds
Illumination Source Monochrome LED
OD Range 0 to 4.000 Abs
Heating Temperature 37°C
Mixing Speed Range 100 to 900 rpm
Printer Yes
Power Consumption 48W
Dimensions 380×350×260 mm
Net Weight 4.1 Kg
Gross Weight 6.5 kg

Pricing

Product Price Unit Action
Nano Spectrophotometer LMNS-A102 $ 7500 Each of 1

Features

7-Inch Touchscreen

Auto-Detection Function

Variable Stirring Speed

Sample Reusability

Fluorometer Detection

High Sensitivity

Built-in Printer

Standard Accessories

Model No

Accessory

LMNS-A102-C1

Cuvette

LMNS-A102-S1

Stirrer

LMNS-A102-U1

U Disk

LMNS-A102-T1

Thermal Printing Paper

LMNS-A102-D1

Dust Cover

Applications

Nano Spectrophotometer LMNS-A102 is ideal for quantifying nucleic acids, proteins, and other micro-volume biomolecules. It is widely employed in molecular biology, genetic research, and clinical diagnostics.

Selection Guide

Nano Spectrophotometer LMNS-A102 is a compact and advanced device designed for micro-volume sample analysis, providing high precision and reliability. Based on research studies, this model is widely used in molecular biology, biochemistry, and pharmaceutical experiments, especially for quantifying DNA, RNA, and protein concentrations. With a minimal sample volume requirement of 0.5 µl to 2 µl, it is best suited for labs handling precious or limited samples. Its versatile path length options (ranging from 0.03 mm to 1.2 mm) support a wide concentration range, enhancing flexibility across varied applications. Equipped with a Xenon lamp light source and a 2048 CMOS array detector, it ensures fast scanning and accurate absorbance readings. This model is often chosen by professionals due to its reliability, compliance with lab certifications, and suitability for high-throughput research workflows, making it a dependable choice for accurate spectrophotometric measurements.

Similar Products

Nano Spectrophotometer LMNS-B106

  • Sample Volume: 0.5 to 2μl
  • Optical Path: 1/0.05mm, automatic conversion
  • Minimum Sample Volume for Cuvette Mode: 20μl
  • Optical Path Length for Cuvette Mode: 1/2/5/10mm
  • Sample Level Height for Cuvette Mode: 5mm

$ 9862.5 / Each of 1

Nano Spectrophotometer LMNS-B105

  • Sample Volume: 0.5 to 2μl
  • Optical Path: 1/0.05mm, automatic conversion
  • Wavelength Range: 190nm to 850nm
  • Wavelength Accuracy: ±1 nm
  • Wavelength Resolution: 2nm

$ 8875 / Each of 1

Nano Spectrophotometer LMNS-B100

  • Loading Amount: 0.3 to 2.5 μl
  • Optical Path: 0.05mm, 2.2mm, 1.0mm
  • Wavelength Range: 190nm to 900nm
  • Wavelength Accuracy: ±1 nm
  • Wavelength Resolution: ≤2nm

$ 8587.5 / Each of 1

Nano Spectrophotometer LMNS-B102
  • Sample Volume: 1 to 2μl
  • Optical Path: 1mm
  • Wavelength Range: 190nm to 850nm
  • Wavelength Accuracy: ±1 nm
  • Wavelength Resolution: 2nm

$ 7650 / Each of 1

Nano Spectrophotometer LMNS-B103
  • Sample Volume: 1 to 2μl
  • Optical Path: 1/0.5/0.05mm, automatic conversion
  • Wavelength Range: 190nm to 850nm
  • Wavelength Accuracy: ±1 nm
  • Wavelength Resolution: 2nm

$ 8000 / Each of 1

Nano Spectrophotometer LMNS-A101

  • Sample Volume: 0.5 µl to 2.0 µl
  • Wavelength Range: 180 to 910 nm
  • Wavelength Accuracy: ± 1nm
  • Absorbance Range: 0.02 to 750 Abs
  • Absorbance Precision: 0.002 Abs

$ 8087.5 / Each of 1

Nano Spectrophotometer LMNS-B101

  • Sample Volume: 1 to 2μl
  • Optical Path: 1mm
  • Wavelength Range: 190nm to 850nm
  • Wavelength Accuracy: ±1 nm
  • Wavelength Resolution: 2nm

$ 7500 / Each of 1

Nano Spectrophotometer LMNS-B104

  • Sample Volume: 1 to 2μl
  • Optical Path Length: 1/0.5/0.05mm, automatic conversion
  • Minimum Sample Volume for Cuvette Mode: 50μl
  • Optical Path Length for Cuvette Mode: 1/2/5/10mm
  • Sample Level Height for Cuvette Mode: 5mm

$ 8975 / Each of 1

Nano Spectrophotometer LMNS-A100
  • Sample Volume Range: 0.5 to 2.0µl
  • Wavelength Range: 180 to 910 nm
  • Wavelength Accuracy: ±1 nm
  • Absorbance Range: 0.02 to 300 Abs
  • Absorbance Precision: 0.002 Abs

$ 7237.5 / Each of 1

Frequently Asked Questions

1 What is a Nano Spectrophotometer?

A Nano Spectrophotometer is an apparatus designed to measure the absorbance and concentration of biomolecules using very small sample volumes.

2 How does Nano Spectrophotometer work?

It works by passing a beam of light through a micro volume sample and measuring the absorbance at specific wavelengths to determine the concentration of biomolecules.

3 Can Nano Spectrophotometer measure protein concentration?

It can measure protein concentration using absorbance at 280 nm or colorimetric assays such as Bradford or BCA.

4 Can Nano Spectrophotometer be used for quality control in laboratories?

It is commonly used in quality control processes to ensure accurate quantification and purity assessment of nucleic acids and proteins.

5 Can Nano Spectrophotometer be used in next-generation sequencing (NGS) workflows?

It is often used in NGS workflows to check nucleic acid concentration and purity before library preparation and sequencing.

6 Is Nano Spectrophotometer used in clinical diagnostics?

It is used in clinical diagnostics to quantify biomolecules such as DNA, RNA, and proteins in samples from patients, ensuring quality control in assays.

7 Can Nano Spectrophotometer be used in microbiology labs?

It is used in microbiology labs for quantifying plasmid DNA, RNA, and proteins extracted from microbial cultures for molecular analysis.

8 What role does Nano Spectrophotometer play in drug development?

It plays an important role in drug development by quantifying target molecules, verifying sample purity, and supporting biomolecular analysis during early-stage research.

9 Is Nano Spectrophotometer useful in vaccine development?

It is useful in vaccine development for quantifying nucleic acids, proteins, and antigen samples during formulation and quality control stages.

10 Does Nano Spectrophotometer support environmental sample analysis?

It supports environmental sample analysis by measuring contaminants like nucleic acids and proteins in soil, water, or microbial samples.