Multi-Channel Data Logger LMMCD-A100

Unleash precision with the Multi-Channel Data Logger LMMCD-A100, a beacon of innovation. Featuring a universal input system supporting TCs, RTDs, mA, VDC, mV, and frequency inputs. It effortlessly handles the diverse needs of industries with its 48-channel capacity. Elevate your measurements with enhanced flow totalization, backed by temperature and pressure compensation. In terms of industrial data logging, the gadget establishes a new standard for ease and accuracy

Catalog Send Mail Whatsapp

Specifications

Input Channels 1 to 48
Thermocouple (TC) input K, J, T, E, R, S, B, N, Wre526, Wre325
RTD Input Pt100, CU50, CU100
Analog Input 4-20 mA, 0-10 mA, 0-5 V, 1-5 V, 0-10 VDC
mV Input 0-20 mV, 0-60 mV, 0-100 mV, 0-500 mV
Working ambient Temperature: 0-50 ℃, Humidity: 10%-85 % (No dew)
Frequency input 0-5 KHz, 3 Channel
Isolation photoelectric isolation
Accuracy ± (0.2%FS +1) digital
Resolution 0.1 ℃ when temperature input
Sample time 1 second per 8 channels
Data Storage Capacity 180 days × Record Interval Time/CH number
RTD Input Type Measured Range Input Independence Pt100 -200 to 600℃ >20 MΩ CU50 -50 to150℃ >20 MΩ
TC Input Type Measured Range Input Independence CU100 -50 to150 ℃ >20 MΩ K -50 to 1300 ℃ >20 MΩ J 0 to 1000 ℃ >20 MΩ T -200 to 350 ℃ >20 MΩ E 0 to 800 ℃ >20 MΩ R -50 to 1700 ℃ > 20 MΩ S -50 to 1700 ℃ > 20 MΩ B 300 to 1800 ℃ >20 MΩ N 0 to 1300 ℃ >20 MΩ Wre 526 0-2300 ℃ >20 MΩ Wre 325 0-2300 ℃ >20 MΩ
Analog Input Type Measured Range Input Independence 4-20 mA -20000 to 20000 250 Ω 0-10 mA -20000 to 20000 500 Ω 0-5 VDC -20000 to 20000 500 KΩ 1-5 VDC -20000 to 20000 500 KΩ
mV Input Type Measured Range Input Independence 0-60 mV -20000 to 20000 >20 MΩ 0-100 mV -20000 to 20000 >20 MΩ
Display 10.4-inch color TFT LCD
LCD Resolution 640 × 480
Interval time 1-3600 seconds, set flexibly
Insulation Power to ground (Housing > 1500 VAC)
Case material Metal for case and bezel
Mounting Panel flush mounting
Power Supply 100-240 VAC, 47-63 Hz
Power 20 W
Dimension 288 × 288 × 180 mm
Net Weight 8.0 Kg

Pricing

Product Price Unit Action
Multi-Channel Data Logger LMMCD-A100 $ 3500 Each of 1

Features

Achieves high accuracy for reliable measurement
TFT LCD display for clear and precise readings
Integrated thermocouple automatic cold junction correction for better accuracy
Provides mathematical function
Memory Flash Drive Data Saving feature enables flexible data management
Durability is ensured by the sturdy metal casing and bezel construction

Applications

Multi-Channel Data Logger LMMCD-A100 finds applications across diverse industries, including manufacturing, energy, and pharmaceuticals, enabling precise and comprehensive monitoring.

Selection Guide

Multi-Channel Data Logger LMMCD-A100 is a versatile and reliable system designed for applications that require monitoring multiple parameters across various channels. It supports up to 48 input channels and is compatible with a wide range of sensor types, including Thermocouples (K, J, T, E, R, S, B, N, Wre526, Wre325), RTDs (Pt100, Cu50, Cu100), and Analog Inputs (4-20 mA, 0-10 mA, 0-5 V, 1-5 V). This makes it suitable for research studies, laboratory experiments, and industrial applications such as process validation, environmental monitoring, material testing, and thermal profiling. It is often used in sectors like pharmaceuticals, energy, food processing, and HVAC systems where accurate, multi-point data logging is essential. With certifications such as CE and ISO, it assures quality and safety compliance. Customers should choose this model based on the number of data points to be monitored, the types of sensors used, and the specific conditions of the intended application.

Frequently Asked Questions

1 What is a Multi-Channel Data Logger?

A Multi-Channel Data Logger is an apparatus designed to simultaneously record data from multiple sensors or input channels for various measurements.

2 How does a Multi-Channel Data Logger work?

It collects and records data from multiple sensors or input sources, storing the information for analysis.

3 What types of sensors can be connected to Multi-Channel Data Logger?

It can connect to sensors such as temperature, humidity, pressure, voltage, current, and pH sensors.

4 What is the difference between a Multi-Channel Data Logger and a standard Single-Channel Data Logger?

A Multi-Channel Data Logger can simultaneously record data from multiple sensors, allowing for more complex monitoring and data collection whereas a Single-Channel Data Logger records data from only one sensor or measurement source at a time.

5 What kind of maintenance does Multi-Channel Data Logger require?

Routine maintenance includes regular sensor calibration, battery checks, and occasional firmware updates.

6 Can Multi-Channel Data Logger be used in pharmaceutical storage?

It is used to monitor and record critical parameters like temperature and humidity in pharmaceutical warehouses or cold chains to ensure compliance with regulations.

7 Is Multi-Channel Data Logger suitable for HVAC system monitoring?

It can track temperature, airflow, and pressure across multiple zones in HVAC systems for performance optimization and troubleshooting.

8 Can Multi-Channel Data Logger be used in environmental monitoring?

It can record temperature, humidity, Carbon dioxide levels, and more across various locations to help assess air quality and environmental changes over time.

9 Can Multi-Channel Data Logger be used in research labs?

It is used to simultaneously monitor multiple experiments or test conditions like voltage, temperature, and pressure over time.

10 Can Multi-Channel Data Logger be used in agriculture or greenhouse monitoring?

It is used to track soil moisture, temperature, humidity, and light levels to optimize growing conditions and improve crop yields.