The Labmate Touch Screen Thermal Cycler boasts cutting-edge Peltier-based technology, ensuring precise and consistent thermal performance. Its adjustable ramping rate enhances user efficiency by reducing processing time. The programmable gradient function facilitates the precise determination of annealing temperatures. Users can conveniently access it via an unlimited USB flash drive or LAN interface. Safety is prioritized with the automatic shut-off/start function. Its vibrant color touch screen enables real-time graphical monitoring of each step, enhancing usability. This thermal cycler finds extensive applications in diverse research fields such as nucleic acid amplification, genotyping, mutagenesis, and beyond. With its state-of-the-art features, Labmate Touch Screen Thermal Cycler is a powerful tool for scientific endeavors demanding accuracy, efficiency, and versatility.
Touch Screen Thermal Cycler (Basic) LMTC-A100 Catalog
| Block Capacity | 16 wells x 0.2 mL |
| Block Temperature Range | 0.1 °C - 99.9 °C |
| Temperature Accuracy | ± 0.25 °C |
| Temperature Uniformity | ± 0.25 °C |
| Ramping Rate | Adjustable |
Touch Screen Thermal Cycler (Basic) LMTC-A101 Catalog
| Block Capacity | 16 wells x 0.2 mL |
| Block Temperature Range | 4 °C - 100 °C |
| Temperature Accuracy | ± 0.25 °C |
| Temperature Uniformity | ± 0.25 °C |
| Ramping Rate | Adjustable |
Touch Screen Thermal Cycler (Basic) LMTC-A102 Catalog
| Block Capacity | 32 wells x 0.2 mL |
| Block Temperature Range | 4 °C - 100 °C |
| Temperature Accuracy | ± 0.25 °C |
| Temperature Uniformity | ± 0.25 °C |
| Ramping Rate | Adjustable |
Touch Screen Thermal Cycler (Basic) LMTC-A103 Catalog
| Block Capacity | 32 wells x 0.2 mL |
| Block Temperature Range | 0.1 °C - 99.9 °C |
| Temperature Accuracy | ± 0.25 °C |
| Temperature Uniformity | ± 0.25 °C |
| Ramping Rate | Adjustable |
Touch Screen Thermal Cycler (Basic) LMTC-A104 Catalog
| Block Capacity | 30 x 0.5 mL , 40 x 0.2 mL , 4 x 12 PCR Strip |
| Block Temperature Range | 4 °C - 99.9 °C |
| Temperature Accuracy | ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C) |
| Temperature Uniformity | ± 0.2 °C |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Basic) LMTC-A105 Catalog
| Block Capacity | 48 x 0.2 mL , 6 x 8 PCR Strip |
| Block Temperature Range | 4 °C - 99.9 °C |
| Temperature Accuracy | ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C) |
| Temperature Uniformity | ± 0.2 °C |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Basic) LMTC-A106 Catalog
| Block Capacity | 96 wells x 0.2 mL |
| Block Temperature Range | 4 °C - 99.9 °C |
| Temperature Accuracy | ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C) |
| Temperature Uniformity | ± 0.2 °C |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Basic) LMTC-A107 Catalog
| Block Temperature Range | 0 °C - 100 °C |
| Temperature Accuracy | ≤ ± 0.2 °C (35 °C - 100 °C) |
| Temperature Uniformity | ± 0.2 °C (95 °C) |
| Ramping Rate | Adjustable |
| Heating Rate | 3.5 °C/s |
Touch Screen Thermal Cycler (Basic) LMTC-A108 Catalog
| Block Temperature Range | 0 °C - 100 °C |
| Temperature Accuracy | ≤ ± 0.2 °C (35 °C - 100 °C) |
| Temperature Uniformity | ± 0.2 °C (95 °C) |
| Ramping Rate | Adjustable |
| Heating Rate | 3.5 °C/s |
Touch Screen Thermal Cycler (Basic) LMTC-A109 Catalog
| Block Temperature Range | 0 °C - 100 °C |
| Temperature Accuracy | ≤ ± 0.2 °C (35 °C - 100 °C) |
| Temperature Uniformity | ± 0.2 °C (95 °C) |
| Ramping Rate | Adjustable |
| Heating Rate | 5 °C/s |
Touch Screen Thermal Cycler (Gradient) LMTC-B100 Catalog
| Block Capacity | 96 x 0.2 mL , 12 x 8 PCR Strip |
| Block Temperature Range | 4 °C - 99.9 °C |
| Temperature Accuracy | ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C) |
| Temperature Uniformity | ± 0.2 °C |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Gradient) LMTC-B101 Catalog
| Block Capacity | 96 x 0.2 mL , 12 x 8 PCR Strip |
| Block Temperature Range | 4 °C - 99.9 °C |
| Temperature Accuracy | ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C) |
| Temperature Uniformity | ± 0.2 °C |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Gradient) LMTC-B102 Catalog
| Block Capacity | 96 x 0.2 mL , 12 x 8 PCR Strip |
| Block Temperature Range | 4 °C - 99.9 °C |
| Temperature Accuracy | ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.15 °C (≥ 95 °C) ; ≤ ± 0.15 °C (≥ 72 °C) |
| Temperature Uniformity | ± 0.2 °C |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Gradient) LMTC-B103 Catalog
| Block Capacity | 96 x 0.2 mL , 12 x 8 PCR Strip |
| Block Temperature Range | 4 °C - 99.9 °C |
| Temperature Accuracy | ≤ ± 0.1 °C (50 °C) ; ≤ ± 0.2 °C (≥ 90 °C) |
| Temperature Uniformity | ± 0.3 °C |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Gradient) LMTC-B104 Catalog
| Block Capacity | 384 wells plate |
| Block Temperature Range | 4 °C - 99.9 °C |
| Temperature Accuracy | ≤ ± 0.1 °C (55 °C) ; ≤ ± 0.2 °C (≥ 90 °C) |
| Temperature Uniformity | ± 0.2 °C |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Gradient) LMTC-B105 Catalog
| Block Temperature Range | 0 °C - 100 °C |
| Temperature Accuracy | ≤ ± 0.2 °C (35 °C - 100 °C) |
| Temperature Uniformity | ± 0.2 °C (95 °C) |
| Ramping Rate | Adjustable |
| Heating Rate | 3.5 °C/s |
Touch Screen Thermal Cycler (Gradient) LMTC-B106 Catalog
| Block Temperature Range | 0 °C - 100 °C |
| Temperature Accuracy | ≤ ± 0.2 °C (35 °C - 100 °C) |
| Temperature Uniformity | ± 0.2 °C (95 °C) |
| Ramping Rate | Adjustable |
| Heating Rate | 3.5 °C/s |
Touch Screen Thermal Cycler (Gradient) LMTC-B107 Catalog
| Block Temperature Range | 0 °C - 100 °C |
| Temperature Accuracy | ≤ ± 0.2 °C (35 °C - 100 °C) |
| Temperature Uniformity | ± 0.2 °C (95 °C) |
| Ramping Rate | Adjustable |
| Heating Rate | 3.5 °C/s |
Touch Screen Thermal Cycler (Gradient) LMTC-B108 Catalog
| Block Temperature Range | 0 °C - 100 °C |
| Temperature Accuracy | ≤ ± 0.2 °C (35 °C - 100 °C) |
| Temperature Uniformity | ± 0.2 °C (95 °C) |
| Ramping Rate | Adjustable |
| Heating Rate | 3.5 °C/s |
Touch Screen Thermal Cycler (Gradient) LMTC-B200 Catalog
| Block Capacity | 6 x 16 wells x 0.2 mL , 96 wells x 0.2 mL , 12 x 8 PCR strips |
| Block Temperature Range | 4 °C - 100 °C |
| Temperature Accuracy | 4 °C - 100 °C |
| Temperature Uniformity | ≤ ± 0.15 °C (≥ 90 °C) |
| Ramping Rate | 0.1 °C - 4 °C |
Touch Screen Thermal Cycler (Basic) LMTC-A200 Catalog
| Capacity | 96 |
| Reaction Volume | 10 to 200ul |
| Tube Type | 96×0.2ml PCR plate, 8×0.2ml PCR tube |
| Block Temperature Range | 4°C to 105°C |
| Heat Lid Temperature Rangs | 30°C to 110°C |