Get Quote
Contact us now to receive a detailed quotation.
The Labmate Standard Sample Concentrator offers a streamlined solution for concentrating numerous samples concurrently, streamlining laboratory workflows. This efficient device employs a nitrogen gas delivery needle and a precision block heater, ensuring rapid and effective sample evaporation. Its applications extend to various scientific processes, including drug screening, hormone analysis, liquid phase chemistry, and mass spectrometry. By simplifying and expediting the concentration of multiple samples in a single batch, this instrument significantly enhances laboratory efficiency and productivity. Its versatility and precise performance make it an invaluable tool for researchers and scientists across diverse fields, enabling them to achieve accurate and timely results in critical applications.
Standard Sample Concentrator LSCC-A100 Catalog
| Temperature Range | RT + 5 °C- 150 °C |
| Blocks Quantity | 1 piece |
| Height of gas needle | 150 mm |
| Temperature accuracy ( 40-100 °C) | ± 0.5 °C |
| Temperature accuracy ( 100-150 °C) | ± 1 °C |
Standard Sample Concentrator LSCC-A101 Catalog
| Temperature Range | RT + 5 °C- 150 °C |
| Blocks Quantity | 2 pieces |
| Height of gas needle | 150 mm |
| Temperature accuracy ( 40-100 °C) | ± 0.5 °C |
| Temperature accuracy ( 100-150 °C) | ± 1 °C |
Sample Concentrator LMSCN-A100 Catalog
| Sample Capacity | 1 standard block |
| Temperature Control Range | Room Temperature +5℃ to 150℃ |
| Temperature Setting Range | 5℃ to 150℃ |
| Temperature Stability at 40 to 100℃ | ±0.5℃ |
| Temperature Stability at 100 to 150℃ | ±1℃ |
Sample Concentrator LMSCN-A101 Catalog
| Sample Capacity | 2 standard blocks |
| Temperature Control Range | Room Temperature +5℃ to 150℃ |
| Temperature Setting Range | 5℃ to 150℃ |
| Temperature Stability at 40 to 100℃ | ±0.5℃ |
| Temperature Stability at 100 to 150℃ | ±1℃ |
Standard Sample Concentrator LMSCN-A102 Catalog
| Block Quantity | 1 |
| Temperature Control Range | RT +5℃ to 150℃ |
| Temperature Set Range | 0℃ to 150℃ |
| Heating Up Rate | Less than or equal to 30min (20℃ to 150℃) |
| Temperature Stability at 40℃ | ±0.3℃ |
Standard Sample Concentrator LMSCN-A103 Catalog
| Block Quantity | 2 |
| Temperature Control Range | RT +5℃ to 150℃ |
| Temperature Set Range | 0℃ to 150℃ |
| Heating Up Rate | Less than or equal to 30min (20℃ to 150℃) |
| Temperature Stability at 40℃ | ±0.3℃ |
Sample Concentrator LMSCN-B100 Catalog
| Temperature Setting Range | 0 to 160℃ |
| Temperature Control Range | RT+5 to 160℃ |
| Block Quantity | 1 |
| Nitrogen Flow Rate | 15L/min |
| Heating Time | Less than or equal to 15min (from 25 to 160℃) |
Sample Concentrator LMSCN-B101 Catalog
| Temperature Setting Range | 0 to 160℃ |
| Temperature Control Range | RT+5 to 160℃ |
| Block Quantity | 2 |
| Nitrogen Flow Rate | 15L/min |
| Heating Time | Less than or equal to 15min (from 25 to 160℃) |
Sample Concentrator LMSCN-B102 Catalog
| Temperature Setting Range | 0 to 160℃ |
| Temperature Control Range | RT+5 to 160℃ |
| Block Quantity | 1 |
| Nitrogen Flow Rate | 15L/min |
| Heating Time | Less than or equal to 15min (from 25 to 160℃) |
Sample Concentrator LMSCN-B103 Catalog
| Temperature Setting Range | 0 to 160℃ |
| Temperature Control Range | RT+5 to 160℃ |
| Block Quantity | 2 |
| Nitrogen Flow Rate | 15L/min |
| Heating Time | Less than or equal to 15min (from 25 to 160℃) |
Sample Concentrator LMSCN-B104 Catalog
| Temperature Control Range | RT+5 to 160℃ |
| Block Quantity | 1 |
| Heating Time | Less than or equal to 15min (from 25 to 160℃) |
| Timing Range | 1min to 99min59sec/∞ |
| Maximum Gas Flow | 15L/min |