Overview
Plant Nutrition Analyzer LMPNA-A100 is a meter for chlorophyll and nitrogen measurement in leaves. The chlorophyll range is 0.0 to 99.9 SPAD. Tolerance is plus or minus 1.0 SPAD from 0 to 50 SPAD. Nitrogen content reads 0.0 to 99.9 milligrams per gram. Leaf surface temperature reads minus 10 to 99.9 degrees Celsius. Humidity reads 0.0 to 99.9 percent relative humidity. The measurement area is 2 by 2 millimeters, and leaf thickness reaches 1.2 millimeters. Each reading takes 2 seconds. Memory holds 2000 results, and Bluetooth sends data. A multi-layer shielding structure limits the effect of outside light and temperature. Testing is non-destructive. Agriculture, forestry, and plant physiology researchers use the analyzer. Assess plant nutrient status with our Plant Nutrition Analyzer for crop monitoring and plant physiology research.
Features :
Chlorophyll Measurement
Reads leaf chlorophyll in SPAD units.
Nitrogen Content Reading
Reports leaf nitrogen content with each test.
Leaf Temperature and Humidity
Reads leaf surface temperature and humidity alongside the nutrient data.
Non-Destructive Testing
Leaves stay on the plant during measurement.
Multi-Point Segment Calibration
Calibrates the meter across several points of the range.
OLED Display
Shows readings and stored data on the screen.
Bluetooth Wireless Transmission
Sends results wirelessly to a connected device.
Data Viewing and Monitoring
Stored readings can be reviewed on the meter.
Specifications :
| Measuring Range | Chlorophyll: 0.0 to 99.9 SPAD, Leaf Surface Temperature: -10 to 99.9°C, Nitrogen Content: 0.0 to 99.9 mg/g, Leaf Surface Humidity: 0.0 to 99.9% RH |
| Measurement Accuracy | Chlorophyll: ±1.0 SPAD (0 to 50 SPAD range at room temp), Leaf Surface Temperature: ±0.5°C, Nitrogen Content: ±5%, Leaf Surface Humidity: ±0.5% |
| Repeatability | Chlorophyll: ±0.3 SPAD (0 to 50 SPAD range), Leaf Surface Temperature: ±0.2°C, Nitrogen Content: ±0.5 units, Leaf Surface Humidity: ±0.5% |
| Measurement Area | 2 × 2 mm |
| Maximum Measured Thickness | 1.2 mm |
| Measurement Time Interval | 2 seconds |
| Data Storage Capacity | 2000 |
| Power Supply | 2 × 1.5V dry batteries |
| Dimension | 320 × 250 × 200mm |
| Weight | 2.5 kg |
Applications :
Applications: Agriculture | Forestry | Plant Physiology Research | Nutrient Monitoring | Crop Management
Functions: Chlorophyll Measurement | Nitrogen Content Measurement | Leaf Temperature and Humidity Reading