Get Quote
Contact us now to receive a detailed quotation.
The Micro-Spectrophotometer boasts a robust construction, utilizing stainless steel and quartz fiber materials to ensure durability. It employs a Xenon flash lamp as a light source, characterized by its extended lifespan and consistent performance. This full-wavelength instrument excels in precision, reproducibility, and speed when measuring sample volumes within the range of 0.3 – 2.0 µl. Data transfer options include USB and network connectivity, while measurement results are automatically archived in spreadsheet format. Functioning as a Nano-spectrometer, it covers a broad spectrum from 190 – 1100 mm. Remarkably, the instrument achieves accurate measurements of trace samples ranging from 1.0 to 2.0 ?L with exceptional repeatability. The device efficiently automates the entire detection process, accommodating undiluted high-concentration samples up to 50 times the measured concentration range. Equipped with two USB ports and integrated Bluetooth capabilities, it offers versatile connectivity to a variety of devices.
Micro-Spectrophotometer LMMS-801 Catalog
| Light Path | 1 mm, 0.05 mm |
| Sample Volume Requirements | 1 to 2μL |
| Light Source | Xenon Lamp |
| Detector | 2048-element linear silicide CCD array |
| Detection Range | 200 to 850 nm |
Micro Spectrophotometer LMMS-802 Catalog
| Optical Path | l/0.5/0.05 mm automatic conversion |
| Optical Range | 190-1100 nm |
| Sample Volume | 0.3-2.0 µl |
| Light Source | Long life xenon lamp |
| Detector | 3864 linear CCD array |
Micro Spectrophotometer LMMS-803 Catalog
| Wavelength Range | 190 to 850nm |
| Light Range | 0.02mm, 0.05mm (High concentration measurement)0.2mm, 1.0mm (General concentration measurement) |
| Light Source | Xenon flashing light |
| Absorbance Range | 0.02 to 300A |
| Absorbance Precision | 002Abs (0.2mm Light Range) |
Micro Spectrophotometer LMMS-A900 Catalog
| Sample Volume | 0.5 to 2.0 µL |
| Wavelength Range | 180 to 910 nm |
| Cuvette Measurement (OD600) | 600 ± 8 nm |
| Nucleic Acid Range | dsDNA: 2 to 15000 ng/µL, ssDNA: 1.32 to 9900 ng/µL, RNA: 1.6 to 12000 ng/µL |
| Protein Detection Range | A280: 0.04 to 300 mg/mL, BSA: 0.06 to 447.76 mg/mL, IgG: 0.03 to 218.98 mg/mL, Lysozyme: 0.015 to 113.64 mg/mL |
Micro Spectrophotometer LMMS-A901 Catalog
| Wavelength Range | 180 to 910 nm |
| Wavelength Accuracy | ±1 nm |
| Sample Volume | 0.5μl ~ 2μl, advice 2μl |
| Spectral Resolution | ≤1.5 nm (FWHM@ Hg 253.7nm) |
| Detector | 2048-element linear CMOS array |