Overview

Gas Chromatography LMCG-101 is a type of device that performs qualitative and quantitative studies with sample injector and evaporator chamber. It is a high-performance system with an advanced microcomputer-based temperature management system. The design includes two distinct analog signal outputs, a column oven, a data acquisition system, a real-time instrument monitoring system, the acquisition of detecting signals, PC control, flexible sample injection, and M6 software. With an automatic back door opening, the oven allows for speedy heating and cooling of up to three chromatographic columns.

Specifications :
Sample Introduction System Sample Injector and Evaporator Chamber
Column Oven
Temperature Range Ambient temperature +7℃ to 420℃ (in 1℃ increment)
Accuracy ± 0.02℃
Cooling Time 350℃ to 100℃ ≤ 3 min, 400℃ to 50℃ in 8 – 10 min at 25℃ ambient
Programmed Temperature Setting 0.1℃ - 80℃ / min (in 1℃ increment)
Program Ramps 20 Ramps in total (99 ramps available with control workstation)
Dimensions (L × W × H) 284 × 280 × 241 mm (inside); 340 × 345 × 281 mm (outside)
Flame Ionization Detector (FID)
Detection Limit ≤ 8 × 10-12 g/s (C16)
Drift ≤ 1.5 × 10-13 A/ 30 min
Noise ≤ 3 × 10-14A
Linearity Range ≥ 10⌃6
Injector Split/ non split capillary
Software M6 software
Control System EPC (electronic pneumatic control)
Display 7-inch touch screen
Features :
  • -  Two independent analog signal outputs
  • -  High sensibility and stability detector
  • -  Flexible sample injection, 2 sample injectors
  • -  Advanced built-in data acquisition system
  • -  The oven allows for quick heating and cooling
  • -  M6 software, compatible with GLP/FDA-21 CFR
  • -  Designed for monitoring and controlling the instrument via computer
  • -  Electronic pneumatic control system
  • -  7-inch touch screen display
Standard Accessories :

S.No. Accessories Name
1 FID Detector System
2 Injector
3 M6 Software

Optional Accessories :

SR. NO. Accessories Name Parameter Measuring Range
1 Thermal Conductivity Detector (TCD) Sensitivity ≥10000 mV, mL/mg (n-hexadecane)
Baseline Noise ≤20 ????V
Drift ≤ 100 ????V/ 30 min
Linearity Range ≥ 104
2 Flame Photometric Detector (FPD) Detection Limit ≤ 8 × 10-13 g/s (P); ≤ 8 × 10-11g/s(S)
Drift ≤ 2 × 10-11 A/30min
Baseline Noise ≤ 5 × 10-12A
3 Nitrogen-Phosphorus Detector (NPD) Detection Limit ≤ 5 × 10-12g/s (N) (Azobenzene); ≤ 5 × 10-13g/s (P) Malathion)
4 Electron Capture Detector (ECD) Linear Range ≥ 10⌃3 (????- 666)
Baseline Drift ≤100 ????V/30 min
Baseline Noise ≤40 ????V
Detection Limit ≤3 × 10-14 g/ml (????-666)
5 PIP Injector Packed Column Injector

Applications :

Gas chromatography is primarily employed in the areas of food and technology, pharmaceutical drug testing, environmental monitoring, forensics, biological analysis, geochemical research, and clinical analysis for the separation and detection of thermally stable chemical substances.

labamte