Overview

Gas Chromatography LMCG-101 has temperature range of 7°C to 450°C. It ensures stable thermal control and efficient column performance. Equipped with an advanced detector that delivers consistent results. Integrated with an intuitive touchscreen that allows seamless operation. Our Gas Chromatography supports analytical settings in pharmaceuticals, petrochemicals, and environmental testing.

Features :

Computer-controlled system

Multistage temperature control

Real-time status monitoring

Rapid heat-up and cool-down

Dual injector operation

Independent signal output

Specifications :

Temperature Range 7ºC to 420ºC
Temperature Accuracy ±0.02ºC
Cooling Time 350°C to 100°C ≤ 3 min
400°C to 50°C in 8-10 min at 25°C ambient
Programmed Temperature Range 0.1℃ to 80℃/min
Program Ramps 20 Ramps
FID Detection Time ≤8×10-12 g/s (n-hexadecane)
FID Baseline Drift ≤1.5×10-13 A/h
FID Baseline Noise ≤3×10-14 A
FID Linearity ≥106
TCD Maximum Operating Temperature 400ºC
TCD Temperature Accuracy ±0.1ºC
TCD Detector Sensitivity ≥ 10000 mV × mL / mg (n-Hexadecane)
TCD Baseline Noise ≤20uv
TCD Baseline Drift ≤100uv/30 min
TCD Linear Dynamic Range ≥104
FPD Detection ≤8×10‐13 g/s(P); ≤8×10‐11 g/s(S)
FPD Baseline Drift ≤2×10‐11 A/30 min
FPD Baseline Noise ≤5×10‐12 A
NPD Detection Limit ≤5×10-12 g/s(N) (Azobenzene)
≤5×10-13 g/s(P) (Malathion)
ECD Detection Limit ≤3×10-14 g/ml
ECD Baseline Drift ≤ 100 μV/30 min
ECD Baseline Noise ≤40μV
Internal Dimension (W×D×H) 284×280×241 mm
External Dimension (W×D×H) 340×345×281 mm

Standard Accessories :

M6 Software

Optional Accessories :

Model No.

Accessory

Quantity

Unit

LMCG-101-GC1

Split/Non-split capillary injector

1

Each

LMCG-101-GC2

Flame Ionization Detector (FID)

1

Each

LMCG-101-GC3

Thermal Conductivity Detector (TCD)

1

Each

LMCG-101-GC4

Flame Photometric Detector (FPD)

1

Each

LMCG-101-GC5

Electron Capture Detector (ECD)

1

Each

LMCG-101-GC6

Nitrogen Phosphorus Detector (NPD)

1

Each

LMCG-101-GC7

Autosampler 22 places 

1

Each

LMCG-101-GC8

Autosampler 156 places

1

Each

Applications :

Gas Chromatography LMCG-101 is employed in pharmaceuticals, petrochemicals, food safety, and environmental analysis. It ensures reliable compound separation and detection in complex mixtures.

Selection Guide :

Gas Chromatography LMCG-101 is designed for the separation and analysis of volatile and semi-volatile compounds. It is widely used in applications such as environmental monitoring, pharmaceutical quality control, food and beverage testing, petrochemical analysis, and forensic investigations. Based on research studies, it is particularly suitable for quantitative and qualitative analysis in both routine and complex experiments. This system provides a temperature control range up to 450°C, high-accuracy sample injection, and advanced electronic pressure control (EPC) for stable performance. It meets international certifications like ISO and CE, ensuring reliability and compliance with laboratory standards. Customers looking for a robust system for research, QA/QC labs, or regulatory testing can confidently choose this model based on its proven performance, certified quality, and versatile application support.