Get Quote
Contact us now to receive a detailed quotation.
Labmate Environmental Testing Chamber provides uniform temperature control for testing various samples. They are Constructed with acid and corrosion-resistant materials for long-lasting durability across laboratory environments. They are equipped with fault warning systems and over-temperature protection to ensure safe testing . Their intuitive digital controls allow seamless monitoring and parameter adjustments. Our Environmental Testing Chambers are ideal for evaluating product durability, performance, and material behaviour.
Environmental Testing Chamber LMETC-A100 Catalog
| Temperature Range | -70°C to 150°C |
| Humidity Range | 20% to 98% R.H. |
| Accuracy/Uniformity | ±0.1°C, ±0.1% R.H. / ±1.0°C, ±3.0% R.H. |
| Accuracy/Volatility | ±1.0°C, ±2.0% R.H. / ±0.5°C, ±2.0% R.H. |
| Capacity | 80L |
Environmental Testing Chamber LMETC-A101 Catalog
| Temperature Range | -60℃ to 150℃ |
| Humidity Range | 20% to 98% R.H. |
| Accuracy/Uniformity | ±0.1°C, ±0.1% R.H. / ±1.0°C, ±3.0% R.H. |
| Accuracy/Volatility | ±1.0°C, ±2.0% R.H. / ±0.5°C, ±2.0% R.H. |
| Capacity | 80L |
Environmental Testing Chamber LMETC-A102 Catalog
| Temperature Range | -40℃ to 150℃ |
| Humidity Range | 20% to 98% R.H. |
| Accuracy/Uniformity | ±0.1°C, ±0.1% R.H. / ±1.0°C, ±3.0% R.H. |
| Accuracy/Volatility | ±1.0°C, ±2.0% R.H. / ±0.5°C, ±2.0% R.H. |
| Capacity | 80L |
Environmental Testing Chamber LMETC-A103 Catalog
| Temperature Range | -40℃ to 150℃ |
| Temperature Accuracy | ±0.2℃ |
| Humidity Range | 20% to 98% R.H |
| Humidity Accuracy | ±2.5% R.H |
| Heating Up Time | -40℃ to 100℃ within 45 minutes |
Environmental Testing Chamber LMETC-B100 Catalog
| Temperature Range | -20℃ to 150℃ |
| Humidity Range | 20% to 98% R.H. |
| Accuracy/Uniformity | ±0.1°C, ±0.1% R.H. / ±1.0°C, ±3.0% R.H. |
| Accuracy/Volatility | ±1.0°C, ±2.0% R.H. / ±0.5°C, ±2.0% R.H. |
| Capacity | 800L |
Environmental Testing Chamber LMETC-B101 Catalog
| Temperature Range | -40℃ to 150℃ |
| Humidity Range | 20% to 98% R.H |
| Accuracy/Uniformity | ±0.1°C, ±0.1% R.H. / ±1.0°C, ±3.0% R.H. |
| Accuracy/Volatility | ±1.0°C, ±2.0% R.H. / ±0.5°C, ±2.0% R.H. |
| Capacity | 800L |
Environmental Testing Chamber LMETC-B102 Catalog
| Temperature Range | -60℃ to 150℃ |
| Humidity Range | 20% to 98% R.H. |
| Accuracy/Uniformity | ±0.1°C, ±0.1% R.H. / ±1.0°C, ±3.0% R.H. |
| Accuracy/Volatility | ±1.0°C, ±2.0% R.H. / ±0.5°C, ±2.0% R.H. |
| Capacity | 800L |
Environmental Testing Chamber LMETC-B103 Catalog
| Temperature Range | -70℃ to 150℃ |
| Humidity Range | 20% to 98% R.H. |
| Accuracy/Uniformity | ±0.1°C, ±0.1% R.H. / ±1.0°C, ±3.0% R.H. |
| Accuracy/Volatility | ±1.0°C, ±2.0% R.H. / ±0.5°C, ±2.0% R.H. |
| Capacity | 800L |
Environmental Testing Chamber LMETC-A104 Catalog
| Volume | 150 L |
| Temperature Range | -20℃ to 150℃ |
| Temperature Deviation | less than or equal to ±2.0℃ |
| Temperature Resolution | 0.1℃ |
| Temperature Uniformity | Less than or equal to ±2℃ |
Environmental Testing Chamber LMETC-B104 Catalog
| Volume | 800 L |
| Temperature Range | 0°C to 150°C |
| Temperature Fluctuation | Less than or equal to ±0.4°C |
| Temperature Evenness | Less than or equal to ±1°C |
| Temperature Deviation | Less than or equal to 1°C |