Get Quote
Contact us now to receive a detailed quotation.
Labmate Differential Pressure Meter measures pressure differences from 0 to 500 Pa to assess flow and system performance. These withstand harsh conditions such as high temperatures and aggressive chemicals. They have digital readouts for precision and analog dials for simplicity. They have signal outputs for integration with automated control systems or data loggers. Our Differential Pressure Meter serves HVAC, flow measurement, industrial processes, filter monitoring, tank level, and boiler systems.
Differential Pressure Meter LMDPM-A100 Catalog
| Measuring range | 0 to 125 Pa |
| Linear error | 0 ± 0.2 Pa |
| Accuracy | ± 1 % |
| Temperature range | 0 °C to 50 °C |
| Humidity | ˂ 85 RH |
Differential Pressure Meter LMDPM-A200 Catalog
| Measuring range | ± 500 Pa |
| Temperature range | 0°C to 50°C |
| Data storage capacity | 16000 samples |
| Repeatability | ± 0.2 % FS |
| Resolution | 0.1 Pa |