Get Quote
Contact us now to receive a detailed quotation.
Cooling Incubators combine refrigeration and heating, so they hold set points below and above room temperature. A standard heated incubator can only warm. Chamber volumes run from 80 to 1075 L. Standard models work from 0 to 60 degrees C, and extended models from minus 10 to 75 degrees C. Stability is within 0.5 degrees C, or within 1 degree C when standard models cool. Uniformity across the chamber is within 1 degree C. Timers run up to 9999 minutes. An over-temperature alarm protects samples if control fails. A refrigerated lab incubator suits BOD testing at 20 degrees C and cold-loving microbes. Other uses include insect and plant studies, enzyme work and stability testing.
Cooling Incubator LMCI-A200 Catalog
| Chamber Volume | 175 L |
| Temperature Range | -10 to 75 ℃ |
| Temperature Stability | ±0.5℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 0 to 9999min |
Cooling Incubator LMCI-A201 Catalog
| Chamber Volume | 275 L |
| Temperature Range | -10 to 75 ℃ |
| Temperature Stability | ±0.5℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 0 to 9999min |
Cooling Incubator LMCI-A202 Catalog
| Chamber Volume | 375 L |
| Temperature Range | -10 to 75℃ |
| Temperature Stability | ±0.5℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 0 to 9999min |
Cooling Incubator LMCI-A203 Catalog
| Chamber Volume | 475 L |
| Temperature Range | -10 to 75℃ |
| Temperature Stability | ±0.5℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 0 to 9999min |
Cooling Incubator LMCI-A204 Catalog
| Chamber Volume | 800 L |
| Temperature Range | -10 to 75℃ |
| Temperature Stability | ±0.5℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 0 to 9999min |
Cooling Incubator LMCI-A205 Catalog
| Chamber Volume | 1075L |
| Temperature Range | -10 to 75℃ |
| Temperature Stability | ±0.5℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 0 to 9999min |
Cooling Incubator LMCI-A100 Catalog
| Chamber Volume | 80 L |
| Temperature Range | 0 to 60 ℃ |
| Temperature Stability | Heating:±0.5℃;Cooling:±1℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 1 to 9999min |
Cooling Incubator LMCI-A101 Catalog
| Chamber Volume | 150 L |
| Temperature Range | 0 to 60 ℃ |
| Temperature Stability | Heating:±0.5℃;Cooling:±1℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 1 to 9999min |
Cooling Incubator LMCI-A102 Catalog
| Chamber Volume | 200 L |
| Temperature Range | 0 to 60 ℃ |
| Temperature Stability | Heating:±0.5℃;Cooling:±1℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 1 to 9999min |
Cooling Incubator LMCI-A103 Catalog
| Chamber Volume | 250 L |
| Temperature Range | 0 to 60 ℃ |
| Temperature Stability | Heating:±0.5℃;Cooling:±1℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 1 to 9999min |
Cooling Incubator LMCI-A104 Catalog
| Chamber Volume | 300 L |
| Temperature Range | 0 to 60 ℃ |
| Temperature Stability | Heating:±0.5℃;Cooling:±1℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 1 to 9999min |
Cooling Incubator LMCI-A105 Catalog
| Chamber Volume | 400 L |
| Temperature Range | 0 to 60 ℃ |
| Temperature Stability | Heating:±0.5℃;Cooling:±1℃ |
| Temperature Uniformity | ±1℃ |
| Timing Range | 1 to 9999min |
Cooling Incubator LMCI-A106 Catalog
| Chamber Volume | 50 L |
| Temperature Control Range | RT -17 to 65 °C |
| Lowest Temperature | About 8 °C at 25 °C ambient |
| Temperature Control Accuracy | ±0.1 °C |
| Display Resolution | 0.1 °C |