Overview

Calcium Meter LMCAM-A100 employs a calcium ion selective electrode and offers a measurement accuracy of ± 0.5 % F.S. It can measure a concentration range from 0.02 to 4000 ppm and can store data up to 500 sets. Provides USB communication interface to transfer data and allow users to set parameters through the system menu. Includes Calibration due reminder for regular calibration of the meter with 2 - 5 points calibration.

Specifications :
Ca Measurement Range 5 × 10⁷ to 1 M, 0.02 to 4000 ppm
Ca Measurement Accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Temperature Measurement Range 0 to 105 °C, 32 to 221 °F
Temperature Accuracy ± 0.5 °C, ± 0.9 °F
Temperature Resolution 0.1°C
Temperature Compensation 0 to 100 °C, 32 to 212 °F
mV Range (-1999.9) to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1 mV
Calibration Points 2 to 5 points
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Compensation Mode Manual or automatic
Data Hold Function Manual or automatic endpoint detection
Reset Function Yes
Stability Condition Low or high
Calibration Due 0 to 31 days
Power Off Manual or automatic (10,20,30 minutes)
Memory Stores up to 500 sets of data
Output USB communication interface
Connector BNC
Display LCD (130 × 110 mm)
Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
Dimension (L × W × H) 210 × 188 × 60 mm
Weight 1.5 kg
Features :
  • -  Fitted with a Stability indicator for real-time information
  • -  Equipped with a large LCD display
  • -  Facilitates direct ion concentration readout simplifying measurement process
  • -  Advanced with a reset setting function
  • -  Integrated with auto hold function for better recording
  • -  Utilizes automatic electrode diagnosis function to maintain sensor performance
  • -  Designed with a built-in real-time clock to timestamp events
  • -  Enhanced with temperature compensation for accurate results
Standard Accessories :

Calcium ion selective electrode


Temperature probe
Standard solution (1000 ppm)
Ionic strength adjuster (30 mL)
USB cable
DC 5 V Power adapter

Optional Accessories :

Ca ion selective electrode range: 0.02 - 4000 ppm


Ion standard solutions: 480 mL / bottle
Ionic strength adjuster: 480 mL / bottle
Temperature probe with sensor

Applications :

Calcium meter is a device used to measure the concentration of calcium ions in a solution. They are commonly used in various industries, including agriculture, environmental monitoring, water treatment, and research.